Changes for page Processor Setup
                  Last modified by Alexander Mott on 2025/04/30 15:55
              
      
      From version  51.1 
    
    
              edited by Alexander Mott
        
on 2024/03/27 15:23
     on 2024/03/27 15:23
      Change comment:
              There is no comment for this version
          
         
      To version  52.1 
    
    
              edited by Alexander Mott
        
on 2024/03/27 15:23
     on 2024/03/27 15:23
      Change comment:
              There is no comment for this version
          
         Summary
- 
          Page properties (1 modified, 0 added, 0 removed)
 
Details
- Page properties
 - 
      
- Content
 -   
... ... @@ -70,7 +70,7 @@ 70 70 ** Never connect an external router to the Control Subnet, as doing so will cause the internal DHCP server to shut down. 71 71 ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on## 72 72 *** This will force the processor to wait until the router has started before attempting to load the ShowRunnerCLC™ program, avoiding potential license validation issues if the processor boots up before the router. 73 -*** **ShowRunnerCLC™ .puf versions 3.042 and newer includethis commandinthe "Configure Processor with Router" option.**73 +*** ShowRunnerCLC™ .puf versions 3.042 and newer automatically run this command when the "Configure Processor with Router" option is selected. 74 74 ** The previously listed "ipa," "ipm," etc. commands will configure settings for the processor's LAN port, which should be connected to the building LAN or third party network. 75 75 ** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be left in DHCP mode and connected to the Control Subnet port. 76 76 *** The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration.