Changes for page Processor Setup

Last modified by Alexander Mott on 2024/12/02 19:04

From version 49.1
edited by Alexander Mott
on 2024/03/27 15:18
Change comment: There is no comment for this version
To version 50.1
edited by Alexander Mott
on 2024/03/27 15:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -67,6 +67,7 @@
67 67  *** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address
68 68  *** Run the above commands to disable DHCP and assign a static IP address to the processor
69 69  * For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4), there are some additional considerations and setup that must be performed: 
70 +** Never connect an external router to the Control Subnet, as doing so will cause the internal DHCP server to shut down.
70 70  ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on##
71 71  *** This will force the processor to wait until the router has started before attempting to load the ShowRunnerCLC™ program, avoiding potential license validation issues if the processor boots up before the router.
72 72  *** ShowRunnerCLC™ .puf versions 3.042 and newer include this command in the "Configure Processor with Router" option.