Changes for page Processor Setup
Last modified by Alexander Mott on 2024/12/02 19:04
From version 49.1
edited by Alexander Mott
on 2024/03/27 15:18
on 2024/03/27 15:18
Change comment:
There is no comment for this version
To version 50.1
edited by Alexander Mott
on 2024/03/27 15:22
on 2024/03/27 15:22
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,6 +67,7 @@ 67 67 *** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address 68 68 *** Run the above commands to disable DHCP and assign a static IP address to the processor 69 69 * For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4), there are some additional considerations and setup that must be performed: 70 +** Never connect an external router to the Control Subnet, as doing so will cause the internal DHCP server to shut down. 70 70 ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on## 71 71 *** This will force the processor to wait until the router has started before attempting to load the ShowRunnerCLC™ program, avoiding potential license validation issues if the processor boots up before the router. 72 72 *** ShowRunnerCLC™ .puf versions 3.042 and newer include this command in the "Configure Processor with Router" option.