Changes for page Processor Setup
Last modified by Alexander Mott on 2024/12/02 19:04
From version 4.1
edited by Alexander Mott
on 2022/06/09 19:01
on 2022/06/09 19:01
Change comment:
There is no comment for this version
To version 3.1
edited by Alexander Mott
on 2022/06/09 17:21
on 2022/06/09 17:21
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -27,25 +27,8 @@ 27 27 28 28 * Obtain the latest build of ShowRunner [[https:~~/~~/files.chiefintegrations.com/s/WHNzXrrZbB5jC3E>>url:https://files.chiefintegrations.com/s/WHNzXrrZbB5jC3E]] 29 29 * Set the processor’s IP Address per your network requirements 30 -** When connecting to a 4-series processor or a 3-series processor with authentication enabled for the first time, it will prompt for the creation of an admin-level CWS user 31 -*** Input the desired username and password into the dialog box. Save this login information, as it is not possible to recover if it is lost or forgotten 32 -*** In the event that the processor does not allow you to log in with the chosen credentials (i.e. it repeatedly prompts for credentials) 33 -**** Attempt to log in with username "crestron" and no password 34 -**** Once logged into Text Console, run the following commands, replacing [BRACKETS] with your desired credentials 35 -***** ##adduser -N:[USERNAME] -P:[PASSWORD]## 36 -***** ##addusertogroup -N:[USERNAME] -G:Administrators## 37 -** Connect to the processor via USB and open Text Console and run the following commands, replacing [BRACKETS] per your network requirements 38 -*** Disable DHCP: ##dhcp 0 off## 39 -*** Set IP address: ##ipa 0 [IPADDRESS]## 40 -*** Set IP subnet mask: ##ipm 0 [IPMASK]## 41 -*** Set default gateway: ##defr 0 [DEFAULTGATEWAY]## 42 -*** Set hostname: ##host [HOSTNAME]## 43 -** It is also possible to configure a processor over Ethernet by using a DHCP server software on your laptop to assign an IP address 44 -*** Configure your DHCP server software to assign IP addresses in the desired range 45 -*** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address 46 -*** Run the above commands to disable DHCP and assign a static IP address to the processor 47 -* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4), lighting hardware should be connected to the Control Subnet port and the building LAN should be connected to the LAN port. Additional setup is required for the Control Subnet. 48 -** Connect to the processor via Text Console and run the command: ##startprogafterrouter on## 30 +* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4): 31 +** Connect to the processor via Text Console and type "startprogafterrouter on" 49 49 *** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues after a power loss. 50 50 ** Networked lighting hardware should be landed on the Control Subnet 51 51 ** The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration ... ... @@ -90,5 +90,5 @@ 90 90 **** Enter the secret used to create the backup. Showrunner will upload the file and verify the secret. 91 91 **** Select "Restart" to load the new configuration 92 92 ** Wait about 45 seconds after loading the configuration for the program to restart completely((( 93 - 76 + 94 94 )))