Changes for page Processor Setup

Last modified by Alexander Mott on 2024/12/02 19:04

From version 36.1
edited by Alexander Mott
on 2022/10/04 22:08
Change comment: There is no comment for this version
To version 30.1
edited by Alexander Mott
on 2022/09/16 20:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,19 +5,20 @@
5 5  
6 6  (% class="box warningmessage" %)
7 7  (((
8 -SHOWRUNNER™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.**
8 +SHOWRUNNER™ is tested against current Crestron firmware releases.  Please use at least the recommended firmware builds.
9 +3-Series: PUF 1.8001.0146
10 +4-Series: PUF 2.7000.00052.01
11 +VC-4: 2.7000.00047
12 +)))
9 9  
10 -* 3-Series: PUF 1.8001.0146
11 -* 4-Series: PUF 2.7000.00052.01
12 -* VC-4: 2.7000.00047
13 -
14 -**Notes:**
15 -
16 -* Static IP or properly setup DHCP/DNS implementation required.
17 -* Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
14 +(% class="box infomessage" id="HNotes" %)
15 +(((
16 +Notes
17 +Static IP or properly setup DHCP/DNS implementation required.
18 +Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
18 18  )))
19 19  
20 -{{box cssClass="floatinginfobox" title="**CONTENTS**"}}
21 +{{box title="**Contents**"}}
21 21  {{toc/}}
22 22  {{/box}}
23 23  
... ... @@ -98,7 +98,7 @@
98 98  *** Click the "Send" button and click "Yes" to upload the program
99 99  *** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER™
100 100  * Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
101 -** **3-Series processors require authentication enabled** ("##ssl self##" command followed by a reboot can be used but steps will need to be repeated)
102 +** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated)
102 102  ** If stuck on "Connecting to Processor" you will need to accept the certificate
103 103  * For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor
104 104