Changes for page Processor Setup
Last modified by Alexander Mott on 2024/12/02 19:04
From version 35.1
edited by Alexander Mott
on 2022/09/19 16:06
on 2022/09/19 16:06
Change comment:
There is no comment for this version
To version 51.1
edited by Alexander Mott
on 2024/03/27 15:23
on 2024/03/27 15:23
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -5,11 +5,11 @@ 5 5 6 6 (% class="box warningmessage" %) 7 7 ((( 8 -S HOWRUNNER™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.**8 +ShowRunnerCLC™™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.** 9 9 10 -* 3-Series: PUF 1.8001.014 611 -* 4-Series: PUF 2. 7000.00052.0112 -* VC-4: 2.7000.0004710 +* 3-Series: PUF 1.8001.0214 11 +* 4-Series: PUF 2.8003.00037.01 12 +* VC-4: 4.0003.00016 13 13 14 14 **Notes:** 15 15 ... ... @@ -21,9 +21,7 @@ 21 21 {{toc/}} 22 22 {{/box}} 23 23 24 -(% class="row" %) 25 -((( 26 -**ShowRunner Installation Tutorial:** 24 +**ShowRunnerCLC™ Installation Tutorial:** 27 27 28 28 [[https:~~/~~/www.youtube.com/watch?v=xuJ94cMCCa8>>url:https://www.youtube.com/watch?v=xuJ94cMCCa8]] 29 29 ... ... @@ -33,6 +33,20 @@ 33 33 34 34 [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]] 35 35 34 += Error Broadcasting = 35 + 36 +The first thing that should be done after connecting to a processor is to open the Text Console and run the command: ##broadcast on## 37 + 38 +Running the ##broadcast on## command tells the processor to begin logging useful messages to the text console and error log. These messages typically begin with an indication of their severity: 39 + 40 +1. Error: Most errors indicate a major issue that should be investigated and remedied. Some errors will prevent the ShowRunner™ program from starting up or functioning as expected, and may be the result of a configuration issue (e.g. errors registering devices), a network issue (e.g. errors connecting to other devices), or authentication issues (e.g. errors related to connection attempts from clients not providing correct username/password information), among other possible causes. 41 +1. Warning: Warnings indicate issues that are less severe than errors and do not usually prevent the ShowRunner™ program from running, but may result in some unexpected behaviors. 42 +1. Notice: Notices are not a problem, and just give useful information during program startup (e.g. devices registered) and while the program is running (e.g. the times at which scheduled events are triggered) 43 + 44 +Running the ##err sys## command will print the most recent 500 messages to the console. Running the ##clear err## command will clear the log, which is sometimes useful to run before doing a ##progreset## in order to troubleshoot configuration issues on startup. 45 + 46 +To view more than the last 500 messages, connect to the processor with the File Manager tool and navigate to the "Internal Storage > logs" folder. Logs since the last time the processor rebooted are stored in the "CurrentBoot" folder, with a new log started every time the current log reaches ~~1 MB in size. When the processor reboots, the logs in the "PreviousBoot" folder are zipped and moved to the "ZippedLogs" folder, logs in the "CurrentBoot" folder are moved to the "PreviousBoot" folder, and a new log is started in the "CurrentBoot" folder. 47 + 36 36 = IP Configuration = 37 37 38 38 * Connect to the processor via USB and set the processor’s IP Address per your network requirements ... ... @@ -54,12 +54,17 @@ 54 54 *** Configure your DHCP server software to assign IP addresses in the desired range 55 55 *** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address 56 56 *** Run the above commands to disable DHCP and assign a static IP address to the processor 57 -* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4), additional setup is required 69 +* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4), there are some additional considerations and setup that must be performed: 70 +** Never connect an external router to the Control Subnet, as doing so will cause the internal DHCP server to shut down. 58 58 ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on## 59 -*** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues if the processor boots up before the router. 72 +*** This will force the processor to wait until the router has started before attempting to load the ShowRunnerCLC™ program, avoiding potential license validation issues if the processor boots up before the router. 73 +*** **ShowRunnerCLC™ .puf versions 3.042 and newer include this command in the "Configure Processor with Router" option.** 60 60 ** The previously listed "ipa," "ipm," etc. commands will configure settings for the processor's LAN port, which should be connected to the building LAN or third party network. 61 -** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration. 62 -** The Control Subnet will automatically configure itself based on the LAN configuration, but it can optionally be configured manually: 75 +** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be left in DHCP mode and connected to the Control Subnet port. 76 +*** The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration. 77 +*** If lighting hardware is to be connected via the LAN anyway, then you must run the command: ##securegateway default## 78 +*** Note: this setting enables unsecure connections to the processor from the LAN. This is necessary if ZUMNET-JBOXs or other non-secure Crestron devices (such as 3-Series EISC) will be connected via the LAN port of the processor 79 +** The Control Subnet will automatically configure itself based on the LAN configuration, but it should be configured manually if the processor is to be connected to building LAN as the default scheme may cause networking issues: 63 63 *** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox: 64 64 **** Set routing to "Manual" with the start address and subnet size 65 65 **** E.g., a setting of "100.64.0.0/20" will have the processor at 10.64.0.1 with an IP mask of 255.255.240.0 and a default gateway and DNS server at 100.64.0.2 ... ... @@ -70,13 +70,14 @@ 70 70 ** For jobs with Central Control, the IP addresses of the processors matters 71 71 ** Chief Integrations will provide an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists the IP address for each processor. If these IP addresses must be changed during startup, then it will be necessary to also change the IP addresses in the Remote System Definition in the configuration file 72 72 ** See the[[ CoAP Setup Guide>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.CoAP with Crestron S# Library and Modules.CoAP ShowRunner to ShowRunner Setup Instructions.WebHome]] for details 90 +* At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 73 73 74 74 = Program Load = 75 75 76 -* Download the latest build of S HOWRUNNER™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]94 +* Download the latest build of ShowRunnerCLC™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] 77 77 * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network 78 78 ** While it is possible to load the program via USB, it is not recommended because the transfer speed is significantly slower than loading via Ethernet 79 -* Double click the PUF to open the Package Update Tool and install S HOWRUNNER™ (works best with Toolbox closed)97 +* Double click the PUF to open the Package Update Tool and install ShowRunnerCLC™ (works best with Toolbox closed) 80 80 ** The Package Update Tool will automatically open your Address Book and prompt you to select a device 81 81 *** If you have not created an Address Book for this job, close the Address Book window and press the pencil icon 82 82 *** Type in the IP address of your processor and click "OK" ... ... @@ -83,11 +83,11 @@ 83 83 ** Double check that the correct PUF file is listed under the "Package Info" section and that the correct IP address is listed under "Target" 84 84 ** Press the "Recheck" button 85 85 ** Make sure that all three tasks are selected ("Load ShowRunner Program", "Update Crestron App", and "Update XPanel") 86 -** Press the "Update" button to begin loading S HOWRUNNER™104 +** Press the "Update" button to begin loading ShowRunnerCLC™ 87 87 * Sometimes the PUF tool will falsely report a failure to load the program 88 88 ** Connect to the processor via Text Console 89 89 ** Run the command ##sr ver## 90 -** If the console returns with the newly installed version of S HOWRUNNER™, then the installation was successful108 +** If the console returns with the newly installed version of ShowRunnerCLC™, then the installation was successful 91 91 ** If the console returns with "Bad or Incomplete Command (sr)" then the installation was not successful 92 92 *** Rename the downloaded .puf file to be a .zip file and open the archive 93 93 **** Some file archivers (such as 7-Zip) allow you to right click on the PUF file and open the archive without changing the filetype ... ... @@ -96,11 +96,11 @@ 96 96 **** Alternatively, navigate to Functions>SIMPL Program...>SIMPL Program (Program01)... 97 97 *** Under the "Send Program" section, browse your PC and select the extracted .cpz file 98 98 *** Click the "Send" button and click "Yes" to upload the program 99 -*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of S HOWRUNNER™100 -* Once S HOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.101 -** **3-Series processors require authentication enabled** ( SSLself can be used but steps will need to be repeated)117 +*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of ShowRunnerCLC™ 118 +* Once ShowRunnerCLC™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required. 119 +** **3-Series processors require authentication enabled** ("##ssl self##" command followed by a reboot can be used but steps will need to be repeated) 102 102 ** If stuck on "Connecting to Processor" you will need to accept the certificate 103 -* For jobs with multiple processors, S HOWRUNNER™ will need to be loaded to each processor121 +* For jobs with multiple processors, ShowRunnerCLC™ will need to be loaded to each processor 104 104 105 105 = License and Configuration Deployment = 106 106 ... ... @@ -107,7 +107,7 @@ 107 107 * Download the SrConfig.json or CiLightingConfig.json configuration file from the link provided by Chief Integrations 108 108 * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]] 109 109 ** Processors with a Control Subnet should use the LAN MAC address, **not** the Control Subnet MAC address 110 -* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the showrunnerHUB™ web interface128 +* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the ShowRunnerHUB™ web interface 111 111 ** Using Toolbox: 112 112 *** Connect to the processor via Text Console and via File Management 113 113 *** In File management, navigate to the "NVRAM>sr" folder from the left-hand menu ... ... @@ -117,15 +117,17 @@ 117 117 *** Right-click on the right-hand side and select "Copy File(s) From..." and select the downloaded SrConfig.json file 118 118 **** Alternatively, drag and drop the file from your computer to the File Management tool 119 119 **** If you downloaded a CiLightingConfig.json file, it must be renamed to "SrConfig.json" 120 -** Using the showrunnerHUB™ UI: 138 +*** Note: when loading the license and configuration through Toolbox, the "License.lic" file and "SrConfig.json" file must have exact filenames 139 +**** If the files were automatically numbered during download (e.g. by adding a "(1)" or "(2)" to the end of the filename), the files must be renamed before loading them to the processor 140 +** Using the ShowRunnerHUB™ UI: 121 121 *** Using Chrome or Firefox, navigate to the processor's IP address 122 122 *** When prompted, input your credentials and log in 123 123 **** 4-Series processor or 3-Series processor with authentication enabled: Log in using the same admin credentials used to connect to the processor 124 124 **** 3-Series processor without authentication enabled: Connect to the processor via Text Console and run the following command, replacing the "username", "name" and "password" with your desired credentials. 125 -***** ##sradmin username "name" administrators password##126 -***** The username and password should be one word each and are the credentials used to log in to the showrunnerHUB™127 -***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user .128 -*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page145 +***** ##sradmin add user **username **"**name**" Administrators **password**## 146 +***** The username and password should be one word each and are the credentials used to log in to the ShowRunnerHUB™ 147 +***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user 148 +*** Once logged in to the ShowRunnerHUB™ UI, you should be automatically redirected to the File Management page 129 129 **** If you are not automatically redirected, then you can navigate to this page by clicking "Setup" in the top right and then selecting "File Management" from the list on the left 130 130 **** [[image:1654807593390-193.png]] 131 131 **** Under “Upload New License File” ... ... @@ -143,8 +143,10 @@ 143 143 ****** Enter the secret used to create the backup. ShowRunner will upload the file and verify the secret. 144 144 **** Once both the license and either a configuration file or backup have been loaded, click "Restart" 145 145 **** Wait for the processor to finish restarting and then reload the page. 146 -***** 3-Series processors will take 45 to 90 restart 147 -***** 4-Series processors should restart considerably faster 166 +***** 3-Series processors will take 45 to 90 seconds to restart, possibly longer depending on the size and complexity of the configuration 167 +***** 4-Series processors will restart considerably faster 168 +**** If licensed for SR-BNI, you will need to generate a [[free Crestron BACnet License>>https://www.crestron.com/Support/Tools/Licensing-Registration/Bacnet-License-Registration]] 169 +**** If licensed for SR-BNI50, you will need to generate a [[paid Crestron 50+ BACnet Point License>>https://www.crestron.com/Support/Tools/Licensing-Registration/Bacnet-License-Registration]] 148 148 149 149 = Set System Time = 150 150 ... ... @@ -157,15 +157,14 @@ 157 157 ** If your PC is in the incorrect Timezone or the time did not synchronize properly, then manually adjust the Time, Date, and Timezone 158 158 * Press the Apply button 159 159 160 -Note that the Location given in the System Clock... menu of Toolbox is not used by S HOWRUNNER™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the SHOWRUNNER™ UI182 +Note that the Location given in the System Clock... menu of Toolbox is not used by ShowRunnerCLC™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the ShowRunnerCLC™ UI 161 161 162 -* S HOWRUNNER™ XPanel UI:184 +* ShowRunnerCLC™ XPanel UI: 163 163 ** Navigate to Settings>Location and System Clock 164 164 ** Press the Lock icon to enable editing 165 165 ** Adjust the time, timezone, and location as necessary 166 166 ** Press Set System Clock to save the changes 167 -* showrunnerHUB™ Web UI:189 +* ShowRunnerHUB™ Web UI: 168 168 ** Navigate to Setup>System Settings>Location and System Clock 169 169 ** Adjust the time, timezone, and location as necessary 170 170 ** Click Apply to save the changes 171 -)))