Changes for page Processor Setup

Last modified by Alexander Mott on 2024/12/02 19:04

From version 33.1
edited by Alexander Mott
on 2022/09/17 00:24
Change comment: There is no comment for this version
To version 38.1
edited by Scott Kohlmann
on 2023/04/20 22:49
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
1 +XWiki.scott\.kohlmann@chiefintegrations\.com
Content
... ... @@ -5,7 +5,7 @@
5 5  
6 6  (% class="box warningmessage" %)
7 7  (((
8 -SHOWRUNNER™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.**
8 +ShowRunnerCLC is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.**
9 9  
10 10  * 3-Series: PUF 1.8001.0146
11 11  * 4-Series: PUF 2.7000.00052.01
... ... @@ -17,11 +17,13 @@
17 17  * Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
18 18  )))
19 19  
20 -{{box title="**CONTENTS**"}}
20 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}}
21 21  {{toc/}}
22 22  {{/box}}
23 23  
24 -**ShowRunner Installation Tutorial:**
24 +(% class="row" %)
25 +(((
26 +**ShowRunnerCLC™ Installation Tutorial:**
25 25  
26 26  [[https:~~/~~/www.youtube.com/watch?v=xuJ94cMCCa8>>url:https://www.youtube.com/watch?v=xuJ94cMCCa8]]
27 27  
... ... @@ -52,11 +52,12 @@
52 52  *** Configure your DHCP server software to assign IP addresses in the desired range
53 53  *** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address
54 54  *** Run the above commands to disable DHCP and assign a static IP address to the processor
55 -* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4), additional setup is required
57 +* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4), additional setup is required
56 56  ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on##
57 -*** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues if the processor boots up before the router.
59 +*** This will force the processor to wait until the router has started before attempting to load the ShowRunnerCLC™ program, avoiding potential license validation issues if the processor boots up before the router.
58 58  ** The previously listed "ipa," "ipm," etc. commands will configure settings for the processor's LAN port, which should be connected to the building LAN or third party network.
59 -** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration.
61 +** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration. 
62 +*** Lighting hardware can be connected via the LAN port, however for proper functionality you must run the command: ##securegateway default##
60 60  ** The Control Subnet will automatically configure itself based on the LAN configuration, but it can optionally be configured manually:
61 61  *** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox:
62 62  **** Set routing to "Manual" with the start address and subnet size
... ... @@ -71,10 +71,10 @@
71 71  
72 72  = Program Load =
73 73  
74 -* Download the latest build of SHOWRUNNER™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
77 +* Download the latest build of ShowRunnerCLC™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
75 75  * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network
76 76  ** While it is possible to load the program via USB, it is not recommended because the transfer speed is significantly slower than loading via Ethernet
77 -* Double click the PUF to open the Package Update Tool and install SHOWRUNNER™ (works best with Toolbox closed)
80 +* Double click the PUF to open the Package Update Tool and install ShowRunnerCLC™ (works best with Toolbox closed)
78 78  ** The Package Update Tool will automatically open your Address Book and prompt you to select a device
79 79  *** If you have not created an Address Book for this job, close the Address Book window and press the pencil icon
80 80  *** Type in the IP address of your processor and click "OK"
... ... @@ -81,11 +81,11 @@
81 81  ** Double check that the correct PUF file is listed under the "Package Info" section and that the correct IP address is listed under "Target"
82 82  ** Press the "Recheck" button
83 83  ** Make sure that all three tasks are selected ("Load ShowRunner Program", "Update Crestron App", and "Update XPanel")
84 -** Press the "Update" button to begin loading SHOWRUNNER
87 +** Press the "Update" button to begin loading ShowRunnerCLC
85 85  * Sometimes the PUF tool will falsely report a failure to load the program
86 86  ** Connect to the processor via Text Console
87 87  ** Run the command ##sr ver##
88 -** If the console returns with the newly installed version of SHOWRUNNER™, then the installation was successful
91 +** If the console returns with the newly installed version of ShowRunnerCLC™, then the installation was successful
89 89  ** If the console returns with "Bad or Incomplete Command (sr)" then the installation was not successful
90 90  *** Rename the downloaded .puf file to be a .zip file and open the archive
91 91  **** Some file archivers (such as 7-Zip) allow you to right click on the PUF file and open the archive without changing the filetype
... ... @@ -94,11 +94,11 @@
94 94  **** Alternatively, navigate to Functions>SIMPL Program...>SIMPL Program (Program01)...
95 95  *** Under the "Send Program" section, browse your PC and select the extracted .cpz file
96 96  *** Click the "Send" button and click "Yes" to upload the program
97 -*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER
98 -* Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
99 -** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated)
100 +*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of ShowRunnerCLC
101 +* Once ShowRunnerCLC™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
102 +** **3-Series processors require authentication enabled** ("##ssl self##" command followed by a reboot can be used but steps will need to be repeated)
100 100  ** If stuck on "Connecting to Processor" you will need to accept the certificate
101 -* For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor
104 +* For jobs with multiple processors, ShowRunnerCLC™ will need to be loaded to each processor
102 102  
103 103  = License and Configuration Deployment =
104 104  
... ... @@ -105,7 +105,7 @@
105 105  * Download the SrConfig.json or CiLightingConfig.json configuration file from the link provided by Chief Integrations
106 106  * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]]
107 107  ** Processors with a Control Subnet should use the LAN MAC address, **not** the Control Subnet MAC address
108 -* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the showrunnerHUB™ web interface
111 +* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the ShowRunnerHUB™ web interface
109 109  ** Using Toolbox:
110 110  *** Connect to the processor via Text Console and via File Management
111 111  *** In File management, navigate to the "NVRAM>sr" folder from the left-hand menu
... ... @@ -115,15 +115,15 @@
115 115  *** Right-click on the right-hand side and select "Copy File(s) From..." and select the downloaded SrConfig.json file
116 116  **** Alternatively, drag and drop the file from your computer to the File Management tool
117 117  **** If you downloaded a CiLightingConfig.json file, it must be renamed to "SrConfig.json"
118 -** Using the showrunnerHUB™ UI:
121 +** Using the ShowRunnerHUB™ UI:
119 119  *** Using Chrome or Firefox, navigate to the processor's IP address
120 120  *** When prompted, input your credentials and log in
121 121  **** 4-Series processor or 3-Series processor with authentication enabled: Log in using the same admin credentials used to connect to the processor
122 122  **** 3-Series processor without authentication enabled: Connect to the processor via Text Console and run the following command, replacing the "username", "name" and "password" with your desired credentials.
123 123  ***** ##sradmin username "name" administrators password##
124 -***** The username and password should be one word each and are the credentials used to log in to the showrunnerHUB™
127 +***** The username and password should be one word each and are the credentials used to log in to the ShowRunnerHUB™
125 125  ***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user.
126 -*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page
129 +*** Once logged in to the ShowRunnerHUB™ UI, you should be automatically redirected to the File Management page
127 127  **** If you are not automatically redirected, then you can navigate to this page by clicking "Setup" in the top right and then selecting "File Management" from the list on the left
128 128  **** [[image:1654807593390-193.png]]
129 129  **** Under “Upload New License File”
... ... @@ -155,14 +155,15 @@
155 155  ** If your PC is in the incorrect Timezone or the time did not synchronize properly, then manually adjust the Time, Date, and Timezone
156 156  * Press the Apply button
157 157  
158 -Note that the Location given in the System Clock... menu of Toolbox is not used by SHOWRUNNER™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the SHOWRUNNER™ UI
161 +Note that the Location given in the System Clock... menu of Toolbox is not used by ShowRunnerCLC™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the ShowRunnerCLC™ UI
159 159  
160 -* SHOWRUNNER™ XPanel UI:
163 +* ShowRunnerCLC™ XPanel UI:
161 161  ** Navigate to Settings>Location and System Clock
162 162  ** Press the Lock icon to enable editing
163 163  ** Adjust the time, timezone, and location as necessary
164 164  ** Press Set System Clock to save the changes
165 -* showrunnerHUB™ Web UI:
168 +* ShowRunnerHUB™ Web UI:
166 166  ** Navigate to Setup>System Settings>Location and System Clock
167 167  ** Adjust the time, timezone, and location as necessary
168 168  ** Click Apply to save the changes
172 +)))