... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome
1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.WebHome
Content
... ... @@ -1,28 +1,18 @@
1 -(% class="box errormessage" %)
1 +(% class="box warningmessage" %)
2 2  (((
3 -This page is for typical processor setup; for ZUM-HUB4 deployments, see our [[dedicated ZUM-HUB4 page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUM-HUB4 Processor Setup.WebHome]].
3 +showrunner is tested against current Crestron firmware releases.  Please use at least the recommended firmware builds.
4 +3-Series: PUF 1.8001.0146
5 +4-Series: PUF 2.7000.00052.01
6 +VC-4: 2.7000.00047
4 4  )))
5 5  
6 -(% class="box warningmessage" %)
9 +(% class="box infomessage" id="HNotes" %)
7 7  (((
8 -SHOWRUNNER™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.**
9 -
10 -* 3-Series: PUF 1.8001.0146
11 -* 4-Series: PUF 2.7000.00052.01
12 -* VC-4: 2.7000.00047
13 -
14 -**Notes:**
15 -
16 -* Static IP or properly setup DHCP/DNS implementation required.
17 -* Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
11 +Notes
12 +Static IP or properly setup DHCP/DNS implementation required.
13 +Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
18 18  )))
19 19  
20 -{{box title="**Contents**"}}
21 -{{toc/}}
22 -{{/box}}
23 -
24 -(% class="row" %)
25 -(((
26 26  **ShowRunner Installation Tutorial:**
27 27  
28 28  [[https:~~/~~/www.youtube.com/watch?v=xuJ94cMCCa8>>url:https://www.youtube.com/watch?v=xuJ94cMCCa8]]
... ... @@ -33,7 +33,7 @@
33 33  
34 34  [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]]
35 35  
36 -= IP Configuration =
26 +=== IP Configuration ===
37 37  
38 38  * Connect to the processor via USB and set the processor’s IP Address per your network requirements
39 39  ** When connecting to a 4-Series processor or a 3-Series processor with authentication enabled for the first time, it will prompt for the creation of an admin-level CWS user
... ... @@ -59,22 +59,19 @@
59 59  *** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues if the processor boots up before the router.
60 60  ** The previously listed "ipa," "ipm," etc. commands will configure settings for the processor's LAN port, which should be connected to the building LAN or third party network.
61 61  ** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration.
62 -** The Control Subnet will automatically configure itself based on the LAN configuration, but it can optionally be configured manually:
63 -*** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox:
64 -**** Set routing to "Manual" with the start address and subnet size
65 -**** E.g., a setting of "100.64.0.0/20" will have the processor at 10.64.0.1 with an IP mask of 255.255.240.0 and a default gateway and DNS server at 100.64.0.2
66 -*** Using Text Console commands (example for a **100.64.0.0/20** subnet, with a processor IP address of **100.64.0.1**)
67 -**** Set CS IP: ##csrouterprefix **100.64.0.0/20**##
68 -**** Reboot the processor: ##reboot##
52 +** The Control Subnet can be configured manually in the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox
53 +*** Set routing to "Manual" with the start address and subnet size
54 +*** E.g., a setting of "10.0.0.0/24" will have the processor at 10.0.0.1 with an IP mask of 255.255.255.0 and a default gateway and DNS server at 10.0.0.2
55 +** The Control Subnet can also be configured to e.g. **10.0.0.0/24** using Text Console command: ##csrouterprefix **10.0.0.0/24**##
69 69  * If the job has multiple processors, then these steps must be repeated for all processors on the job
70 70  ** For jobs with Central Control, the IP addresses of the processors matters
71 71  ** Chief Integrations will provide an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists the IP address for each processor. If these IP addresses must be changed during startup, then it will be necessary to also change the IP addresses in the Remote System Definition in the configuration file
72 72  ** See the[[ CoAP Setup Guide>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.CoAP with Crestron S# Library and Modules.CoAP ShowRunner to ShowRunner Setup Instructions.WebHome]] for details
73 73  
74 -= Program Load =
61 +=== Program Load ===
75 75  
76 76  * Download the latest build of SHOWRUNNER™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
77 -* Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network
64 +* Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network.
78 78  ** While it is possible to load the program via USB, it is not recommended because the transfer speed is significantly slower than loading via Ethernet
79 79  * Double click the PUF to open the Package Update Tool and install SHOWRUNNER™ (works best with Toolbox closed)
80 80  ** The Package Update Tool will automatically open your Address Book and prompt you to select a device
... ... @@ -89,20 +89,19 @@
89 89  ** Run the command ##sr ver##
90 90  ** If the console returns with the newly installed version of SHOWRUNNER™, then the installation was successful
91 91  ** If the console returns with "Bad or Incomplete Command (sr)" then the installation was not successful
92 -*** Rename the downloaded .puf file to be a .zip file and open the archive
79 +*** Rename the .puf file to be a .zip file and open the archive
93 93  **** Some file archivers (such as 7-Zip) allow you to right click on the PUF file and open the archive without changing the filetype
94 94  *** Extract the "CI.Lighting.ShowRunner.cpz" file
95 -*** In Toolbox, connect to the processor via Text Console, click the lightning bolt icon, and select "SIMPL Program..."
96 -**** Alternatively, navigate to Functions>SIMPL Program...>SIMPL Program (Program01)...
97 -*** Under the "Send Program" section, browse your PC and select the extracted .cpz file
82 +*** In Toolbox, connect to the processor via Text Console and click the lightning bolt icon and select "SIMPL Program..."
83 +*** Under the "Send" section, browse your PC and select the extracted .cpz file
98 98  *** Click the "Send" button and click "Yes" to upload the program
99 99  *** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER™
100 100  * Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
101 -** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated)
102 -** If stuck on "Connecting to Processor" you will need to accept the certificate
103 -* For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor
87 +** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated).
88 +** If stuck on "Connecting to Processor" you will need to accept the certificate.
89 +* For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor.
104 104  
105 -= License and Configuration Deployment =
91 +=== License and Configuration Deployment ===
106 106  
107 107  * Download the SrConfig.json or CiLightingConfig.json configuration file from the link provided by Chief Integrations
108 108  * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]]
... ... @@ -125,7 +125,7 @@
125 125  ***** ##sradmin username "name" administrators password##
126 126  ***** The username and password should be one word each and are the credentials used to log in to the showrunnerHUB™
127 127  ***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user.
128 -*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page
114 +*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page.
129 129  **** If you are not automatically redirected, then you can navigate to this page by clicking "Setup" in the top right and then selecting "File Management" from the list on the left
130 130  **** [[image:1654807593390-193.png]]
131 131  **** Under “Upload New License File”
... ... @@ -146,7 +146,7 @@
146 146  ***** 3-Series processors will take 45 to 90 restart
147 147  ***** 4-Series processors should restart considerably faster
148 148  
149 -= Set System Time =
135 +=== Set System Time ===
150 150  
151 151  It is important for the device clock to be accurate in order for scheduled events to trigger at the appropriate time. If Toolbox is still open, this can be done easily:
152 152  
... ... @@ -168,4 +168,3 @@
168 168  ** Navigate to Setup>System Settings>Location and System Clock
169 169  ** Adjust the time, timezone, and location as necessary
170 170  ** Click Apply to save the changes
171 -)))