Changes for page Processor Setup
Last modified by Alexander Mott on 2024/12/02 19:04
From version 29.1
edited by Alexander Mott
on 2022/09/16 20:47
on 2022/09/16 20:47
Change comment:
There is no comment for this version
To version 36.1
edited by Alexander Mott
on 2022/10/04 22:08
on 2022/10/04 22:08
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,20 +2,22 @@ 2 2 ((( 3 3 This page is for typical processor setup; for ZUM-HUB4 deployments, see our [[dedicated ZUM-HUB4 page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUM-HUB4 Processor Setup.WebHome]]. 4 4 ))) 5 + 5 5 (% class="box warningmessage" %) 6 6 ((( 7 -SHOWRUNNER™ is tested against current Crestron firmware releases. Please use at least the recommended firmware builds. 8 -3-Series: PUF 1.8001.0146 9 -4-Series: PUF 2.7000.00052.01 10 -VC-4: 2.7000.00047 8 +SHOWRUNNER™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.** 9 + 10 +* 3-Series: PUF 1.8001.0146 11 +* 4-Series: PUF 2.7000.00052.01 12 +* VC-4: 2.7000.00047 13 + 14 +**Notes:** 15 + 16 +* Static IP or properly setup DHCP/DNS implementation required. 17 +* Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue) 11 11 ))) 12 -(% class="box infomessage" id="HNotes" %) 13 -((( 14 -Notes 15 -Static IP or properly setup DHCP/DNS implementation required. 16 -Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue) 17 -))) 18 -{{box title="**Contents**"}} 19 + 20 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 19 19 {{toc/}} 20 20 {{/box}} 21 21 ... ... @@ -96,7 +96,7 @@ 96 96 *** Click the "Send" button and click "Yes" to upload the program 97 97 *** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER™ 98 98 * Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required. 99 -** **3-Series processors require authentication enabled** ( SSLself can be used but steps will need to be repeated)101 +** **3-Series processors require authentication enabled** ("##ssl self##" command followed by a reboot can be used but steps will need to be repeated) 100 100 ** If stuck on "Connecting to Processor" you will need to accept the certificate 101 101 * For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor 102 102