7 7  (((
8 -SHOWRUNNER™ is tested against current Crestron firmware releases.  Please use at least the recommended firmware builds.
9 -3-Series: PUF 1.8001.0146
10 -4-Series: PUF 2.7000.00052.01
11 -VC-4: 2.7000.00047
12 -)))
8 +ShowRunnerCLC™™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.**
13 13  
14 -(% class="box infomessage" id="HNotes" %)
15 -(((
16 -Notes
17 -Static IP or properly setup DHCP/DNS implementation required.
18 -Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
10 +* 3-Series: PUF 1.8001.0146
11 +* 4-Series: PUF 2.7000.00052.01
12 +* VC-4: 2.7000.00047
13 +
14 +**Notes:**
15 +
16 +* Static IP or properly setup DHCP/DNS implementation required.
17 +* Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
19 19  )))
20 20  
21 -**ShowRunner Installation Tutorial:**
20 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}}
21 +{{toc/}}
22 +{{/box}}
22 22  
24 +**ShowRunnerCLC™ Installation Tutorial:**
25 +
23 23  [[https:~~/~~/www.youtube.com/watch?v=xuJ94cMCCa8>>url:https://www.youtube.com/watch?v=xuJ94cMCCa8]]
24 24  
25 25  **Licensing tutorial:**
... ... @@ -28,7 +28,7 @@
28 28  
29 29  [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]]
30 30  
31 -=== IP Configuration ===
34 += IP Configuration =
32 32  
33 33  * Connect to the processor via USB and set the processor’s IP Address per your network requirements
34 34  ** When connecting to a 4-Series processor or a 3-Series processor with authentication enabled for the first time, it will prompt for the creation of an admin-level CWS user
... ... @@ -49,11 +49,12 @@
49 49  *** Configure your DHCP server software to assign IP addresses in the desired range
50 50  *** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address
51 51  *** Run the above commands to disable DHCP and assign a static IP address to the processor
52 -* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4), additional setup is required
55 +* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4), additional setup is required
53 53  ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on##
54 -*** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues if the processor boots up before the router.
57 +*** This will force the processor to wait until the router has started before attempting to load the ShowRunnerCLC™ program, avoiding potential license validation issues if the processor boots up before the router.
55 55  ** The previously listed "ipa," "ipm," etc. commands will configure settings for the processor's LAN port, which should be connected to the building LAN or third party network.
56 -** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration.
59 +** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration. 
60 +*** Lighting hardware can be connected via the LAN port, however for proper functionality you must run the command: ##securegateway default##
57 57  ** The Control Subnet will automatically configure itself based on the LAN configuration, but it can optionally be configured manually:
58 58  *** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox:
59 59  **** Set routing to "Manual" with the start address and subnet size
... ... @@ -66,12 +66,12 @@
66 66  ** Chief Integrations will provide an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists the IP address for each processor. If these IP addresses must be changed during startup, then it will be necessary to also change the IP addresses in the Remote System Definition in the configuration file
67 67  ** See the[[ CoAP Setup Guide>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.CoAP with Crestron S# Library and Modules.CoAP ShowRunner to ShowRunner Setup Instructions.WebHome]] for details
68 68  
69 -=== Program Load ===
73 += Program Load =
70 70  
71 -* Download the latest build of SHOWRUNNER™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
75 +* Download the latest build of ShowRunnerCLC™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
72 72  * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network
73 73  ** While it is possible to load the program via USB, it is not recommended because the transfer speed is significantly slower than loading via Ethernet
74 -* Double click the PUF to open the Package Update Tool and install SHOWRUNNER™ (works best with Toolbox closed)
78 +* Double click the PUF to open the Package Update Tool and install ShowRunnerCLC™ (works best with Toolbox closed)
75 75  ** The Package Update Tool will automatically open your Address Book and prompt you to select a device
76 76  *** If you have not created an Address Book for this job, close the Address Book window and press the pencil icon
77 77  *** Type in the IP address of your processor and click "OK"
... ... @@ -78,11 +78,11 @@
78 78  ** Double check that the correct PUF file is listed under the "Package Info" section and that the correct IP address is listed under "Target"
79 79  ** Press the "Recheck" button
80 80  ** Make sure that all three tasks are selected ("Load ShowRunner Program", "Update Crestron App", and "Update XPanel")
81 -** Press the "Update" button to begin loading SHOWRUNNER
85 +** Press the "Update" button to begin loading ShowRunnerCLC
82 82  * Sometimes the PUF tool will falsely report a failure to load the program
83 83  ** Connect to the processor via Text Console
84 84  ** Run the command ##sr ver##
85 -** If the console returns with the newly installed version of SHOWRUNNER™, then the installation was successful
89 +** If the console returns with the newly installed version of ShowRunnerCLC™, then the installation was successful
86 86  ** If the console returns with "Bad or Incomplete Command (sr)" then the installation was not successful
87 87  *** Rename the downloaded .puf file to be a .zip file and open the archive
88 88  **** Some file archivers (such as 7-Zip) allow you to right click on the PUF file and open the archive without changing the filetype
... ... @@ -91,18 +91,18 @@
91 91  **** Alternatively, navigate to Functions>SIMPL Program...>SIMPL Program (Program01)...
92 92  *** Under the "Send Program" section, browse your PC and select the extracted .cpz file
93 93  *** Click the "Send" button and click "Yes" to upload the program
94 -*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER
95 -* Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
96 -** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated)
98 +*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of ShowRunnerCLC
99 +* Once ShowRunnerCLC™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
100 +** **3-Series processors require authentication enabled** ("##ssl self##" command followed by a reboot can be used but steps will need to be repeated)
97 97  ** If stuck on "Connecting to Processor" you will need to accept the certificate
98 -* For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor
102 +* For jobs with multiple processors, ShowRunnerCLC™ will need to be loaded to each processor
99 99  
100 -=== License and Configuration Deployment ===
104 += License and Configuration Deployment =
101 101  
102 102  * Download the SrConfig.json or CiLightingConfig.json configuration file from the link provided by Chief Integrations
103 103  * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]]
104 104  ** Processors with a Control Subnet should use the LAN MAC address, **not** the Control Subnet MAC address
105 -* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the showrunnerHUB™ web interface
109 +* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the ShowRunnerHUB™ web interface
106 106  ** Using Toolbox:
107 107  *** Connect to the processor via Text Console and via File Management
108 108  *** In File management, navigate to the "NVRAM>sr" folder from the left-hand menu
... ... @@ -112,15 +112,17 @@
112 112  *** Right-click on the right-hand side and select "Copy File(s) From..." and select the downloaded SrConfig.json file
113 113  **** Alternatively, drag and drop the file from your computer to the File Management tool
114 114  **** If you downloaded a CiLightingConfig.json file, it must be renamed to "SrConfig.json"
115 -** Using the showrunnerHUB™ UI:
119 +*** Note: when loading the license and configuration through Toolbox, the "License.lic" file and "SrConfig.json" file must have exact filenames
120 +**** If the files were automatically numbered during download (e.g. by adding a "(1)" or "(2)" to the end of the filename), the files must be renamed before loading them to the processor
121 +** Using the ShowRunnerHUB™ UI:
116 116  *** Using Chrome or Firefox, navigate to the processor's IP address
117 117  *** When prompted, input your credentials and log in
118 118  **** 4-Series processor or 3-Series processor with authentication enabled: Log in using the same admin credentials used to connect to the processor
119 119  **** 3-Series processor without authentication enabled: Connect to the processor via Text Console and run the following command, replacing the "username", "name" and "password" with your desired credentials.
120 -***** ##sradmin username "name" administrators password##
121 -***** The username and password should be one word each and are the credentials used to log in to the showrunnerHUB™
122 -***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user.
123 -*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page
126 +***** ##sradmin add user **username **"**name**" Administrators **password**##
127 +***** The username and password should be one word each and are the credentials used to log in to the ShowRunnerHUB™
128 +***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user
129 +*** Once logged in to the ShowRunnerHUB™ UI, you should be automatically redirected to the File Management page
124 124  **** If you are not automatically redirected, then you can navigate to this page by clicking "Setup" in the top right and then selecting "File Management" from the list on the left
125 125  **** [[image:1654807593390-193.png]]
126 126  **** Under “Upload New License File”
... ... @@ -138,10 +138,10 @@
138 138  ****** Enter the secret used to create the backup. ShowRunner will upload the file and verify the secret.
139 139  **** Once both the license and either a configuration file or backup have been loaded, click "Restart"
140 140  **** Wait for the processor to finish restarting and then reload the page.
141 -***** 3-Series processors will take 45 to 90 restart
142 -***** 4-Series processors should restart considerably faster
147 +***** 3-Series processors will take 45 to 90 seconds to restart, possibly longer depending on the size and complexity of the configuration
148 +***** 4-Series processors will restart considerably faster
143 143  
144 -=== Set System Time ===
150 += Set System Time =
145 145  
146 146  It is important for the device clock to be accurate in order for scheduled events to trigger at the appropriate time. If Toolbox is still open, this can be done easily:
147 147  
... ... @@ -152,14 +152,14 @@
152 152  ** If your PC is in the incorrect Timezone or the time did not synchronize properly, then manually adjust the Time, Date, and Timezone
153 153  * Press the Apply button
154 154  
155 -Note that the Location given in the System Clock... menu of Toolbox is not used by SHOWRUNNER™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the SHOWRUNNER™ UI
161 +Note that the Location given in the System Clock... menu of Toolbox is not used by ShowRunnerCLC™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the ShowRunnerCLC™ UI
156 156  
157 -* SHOWRUNNER™ XPanel UI:
163 +* ShowRunnerCLC™ XPanel UI:
158 158  ** Navigate to Settings>Location and System Clock
159 159  ** Press the Lock icon to enable editing
160 160  ** Adjust the time, timezone, and location as necessary
161 161  ** Press Set System Clock to save the changes
162 -* showrunnerHUB™ Web UI:
168 +* ShowRunnerHUB™ Web UI:
163 163  ** Navigate to Setup>System Settings>Location and System Clock
164 164  ** Adjust the time, timezone, and location as necessary
165 165  ** Click Apply to save the changes