... ... @@ -5,19 +5,24 @@
5 5  
6 6  (% class="box warningmessage" %)
7 7  (((
8 -SHOWRUNNER™ is tested against current Crestron firmware releases.  Please use at least the recommended firmware builds.
9 -3-Series: PUF 1.8001.0146
10 -4-Series: PUF 2.7000.00052.01
11 -VC-4: 2.7000.00047
12 -)))
8 +SHOWRUNNER™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.**
13 13  
14 -(% class="box infomessage" id="HNotes" %)
15 -(((
16 -Notes
17 -Static IP or properly setup DHCP/DNS implementation required.
18 -Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
10 +* 3-Series: PUF 1.8001.0146
11 +* 4-Series: PUF 2.7000.00052.01
12 +* VC-4: 2.7000.00047
13 +
14 +**Notes:**
15 +
16 +* Static IP or properly setup DHCP/DNS implementation required.
17 +* Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue)
19 19  )))
20 20  
20 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}}
21 +{{toc/}}
22 +{{/box}}
23 +
24 +(% class="row" %)
25 +(((
21 21  **ShowRunner Installation Tutorial:**
22 22  
23 23  [[https:~~/~~/www.youtube.com/watch?v=xuJ94cMCCa8>>url:https://www.youtube.com/watch?v=xuJ94cMCCa8]]
... ... @@ -28,7 +28,7 @@
28 28  
29 29  [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]]
30 30  
31 -=== IP Configuration ===
36 += IP Configuration =
32 32  
33 33  * Connect to the processor via USB and set the processor’s IP Address per your network requirements
34 34  ** When connecting to a 4-Series processor or a 3-Series processor with authentication enabled for the first time, it will prompt for the creation of an admin-level CWS user
... ... @@ -49,11 +49,12 @@
49 49  *** Configure your DHCP server software to assign IP addresses in the desired range
50 50  *** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address
51 51  *** Run the above commands to disable DHCP and assign a static IP address to the processor
52 -* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4/ZUM-HUB4), additional setup is required
57 +* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4), additional setup is required
53 53  ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on##
54 54  *** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues if the processor boots up before the router.
55 55  ** The previously listed "ipa," "ipm," etc. commands will configure settings for the processor's LAN port, which should be connected to the building LAN or third party network.
56 -** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration.
61 +** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration. 
62 +*** Lighting hardware can be connected via the LAN port, however for proper functionality you must run the command: ##securegateway default##
57 57  ** The Control Subnet will automatically configure itself based on the LAN configuration, but it can optionally be configured manually:
58 58  *** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox:
59 59  **** Set routing to "Manual" with the start address and subnet size
... ... @@ -66,7 +66,7 @@
66 66  ** Chief Integrations will provide an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists the IP address for each processor. If these IP addresses must be changed during startup, then it will be necessary to also change the IP addresses in the Remote System Definition in the configuration file
67 67  ** See the[[ CoAP Setup Guide>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.CoAP with Crestron S# Library and Modules.CoAP ShowRunner to ShowRunner Setup Instructions.WebHome]] for details
68 68  
69 -=== Program Load ===
75 += Program Load =
70 70  
71 71  * Download the latest build of SHOWRUNNER™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
72 72  * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network
... ... @@ -93,11 +93,11 @@
93 93  *** Click the "Send" button and click "Yes" to upload the program
94 94  *** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER™
95 95  * Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
96 -** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated)
102 +** **3-Series processors require authentication enabled** ("##ssl self##" command followed by a reboot can be used but steps will need to be repeated)
97 97  ** If stuck on "Connecting to Processor" you will need to accept the certificate
98 98  * For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor
99 99  
100 -=== License and Configuration Deployment ===
106 += License and Configuration Deployment =
101 101  
102 102  * Download the SrConfig.json or CiLightingConfig.json configuration file from the link provided by Chief Integrations
103 103  * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]]
... ... @@ -141,7 +141,7 @@
141 141  ***** 3-Series processors will take 45 to 90 restart
142 142  ***** 4-Series processors should restart considerably faster
143 143  
144 -=== Set System Time ===
150 += Set System Time =
145 145  
146 146  It is important for the device clock to be accurate in order for scheduled events to trigger at the appropriate time. If Toolbox is still open, this can be done easily:
147 147  
... ... @@ -163,3 +163,4 @@
163 163  ** Navigate to Setup>System Settings>Location and System Clock
164 164  ** Adjust the time, timezone, and location as necessary
165 165  ** Click Apply to save the changes
172 +)))