Changes for page Processor Setup
Last modified by Alexander Mott on 2024/12/02 19:04
From version 25.1
edited by Alexander Mott
on 2022/06/30 17:33
on 2022/06/30 17:33
Change comment:
There is no comment for this version
To version 41.1
edited by Alexander Mott
on 2023/05/15 21:07
on 2023/05/15 21:07
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,25 +1,30 @@ 1 1 (% class="box errormessage" %) 2 2 ((( 3 -This page is for ordinaryprocessor setup.For ZUM-HUB4 deployments, see our [[dedicated ZUM-HUB4 page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUM-HUB4 Processor Setup.WebHome]].3 +This page is for typical processor setup; for ZUM-HUB4 deployments, see our [[dedicated ZUM-HUB4 page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUM-HUB4 Processor Setup.WebHome]]. 4 4 ))) 5 5 6 6 (% class="box warningmessage" %) 7 7 ((( 8 -SHOWRUNNER™ is tested against current Crestron firmware releases. Please use at least the recommended firmware builds. 9 -3-Series: PUF 1.8001.0146 10 -4-Series: PUF 2.7000.00052.01 11 -VC-4: 2.7000.00047 12 -))) 8 +ShowRunnerCLC™™ is tested against current Crestron firmware releases. **Please use at least the recommended firmware builds.** 13 13 14 -(% class="box infomessage" id="HNotes" %) 15 -((( 16 -Notes 17 -Static IP or properly setup DHCP/DNS implementation required. 18 -Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue) 10 +* 3-Series: PUF 1.8001.0146 11 +* 4-Series: PUF 2.7000.00052.01 12 +* VC-4: 2.7000.00047 13 + 14 +**Notes:** 15 + 16 +* Static IP or properly setup DHCP/DNS implementation required. 17 +* Auto-Assigned/Link-Local IP address range of 169.254.x.x not supported (Crestron xPanel issue) 19 19 ))) 20 20 21 -**ShowRunner Installation Tutorial:** 20 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 21 +{{toc/}} 22 +{{/box}} 22 22 24 +(% class="row" %) 25 +((( 26 +**ShowRunnerCLC™ Installation Tutorial:** 27 + 23 23 [[https:~~/~~/www.youtube.com/watch?v=xuJ94cMCCa8>>url:https://www.youtube.com/watch?v=xuJ94cMCCa8]] 24 24 25 25 **Licensing tutorial:** ... ... @@ -28,7 +28,7 @@ 28 28 29 29 [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]] 30 30 31 -= ==IP Configuration ===36 += IP Configuration = 32 32 33 33 * Connect to the processor via USB and set the processor’s IP Address per your network requirements 34 34 ** When connecting to a 4-Series processor or a 3-Series processor with authentication enabled for the first time, it will prompt for the creation of an admin-level CWS user ... ... @@ -49,11 +49,12 @@ 49 49 *** Configure your DHCP server software to assign IP addresses in the desired range 50 50 *** Once the processor is assigned an IP address, connect to it via Text Console at the assigned IP address 51 51 *** Run the above commands to disable DHCP and assign a static IP address to the processor 52 -* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4 /ZUM-HUB4), additional setup is required57 +* For processors with a Control Subnet (CP3N/AV3/PRO3/CP4N/AV4/PRO4), additional setup is required 53 53 ** Connect to the processor via Text Console and run the command: ##startprogafterrouter on## 54 -*** This will force the processor to wait until the router has started before attempting to load the showrunner™ program, avoiding potential license validation issues if the processor boots up before the router.59 +*** This will force the processor to wait until the router has started before attempting to load the ShowRunnerCLC™ program, avoiding potential license validation issues if the processor boots up before the router. 55 55 ** The previously listed "ipa," "ipm," etc. commands will configure settings for the processor's LAN port, which should be connected to the building LAN or third party network. 56 -** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration. 61 +** Lighting control hardware (e.g. TSWs, DIN-CENCN-2s, etc.) should be connected to the Control Subnet port. The processor acts as a DHCP server on the Control Subnet, with addresses that are determined automatically based on the LAN configuration. 62 +*** Lighting hardware can be connected via the LAN port, however for proper functionality you must run the command: ##securegateway default## 57 57 ** The Control Subnet will automatically configure itself based on the LAN configuration, but it can optionally be configured manually: 58 58 *** Using the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox: 59 59 **** Set routing to "Manual" with the start address and subnet size ... ... @@ -66,12 +66,12 @@ 66 66 ** Chief Integrations will provide an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists the IP address for each processor. If these IP addresses must be changed during startup, then it will be necessary to also change the IP addresses in the Remote System Definition in the configuration file 67 67 ** See the[[ CoAP Setup Guide>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.CoAP with Crestron S# Library and Modules.CoAP ShowRunner to ShowRunner Setup Instructions.WebHome]] for details 68 68 69 -= ==Program Load ===75 += Program Load = 70 70 71 -* Download the latest build of S HOWRUNNER™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]77 +* Download the latest build of ShowRunnerCLC™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] 72 72 * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network 73 73 ** While it is possible to load the program via USB, it is not recommended because the transfer speed is significantly slower than loading via Ethernet 74 -* Double click the PUF to open the Package Update Tool and install S HOWRUNNER™ (works best with Toolbox closed)80 +* Double click the PUF to open the Package Update Tool and install ShowRunnerCLC™ (works best with Toolbox closed) 75 75 ** The Package Update Tool will automatically open your Address Book and prompt you to select a device 76 76 *** If you have not created an Address Book for this job, close the Address Book window and press the pencil icon 77 77 *** Type in the IP address of your processor and click "OK" ... ... @@ -78,11 +78,11 @@ 78 78 ** Double check that the correct PUF file is listed under the "Package Info" section and that the correct IP address is listed under "Target" 79 79 ** Press the "Recheck" button 80 80 ** Make sure that all three tasks are selected ("Load ShowRunner Program", "Update Crestron App", and "Update XPanel") 81 -** Press the "Update" button to begin loading S HOWRUNNER™87 +** Press the "Update" button to begin loading ShowRunnerCLC™ 82 82 * Sometimes the PUF tool will falsely report a failure to load the program 83 83 ** Connect to the processor via Text Console 84 84 ** Run the command ##sr ver## 85 -** If the console returns with the newly installed version of S HOWRUNNER™, then the installation was successful91 +** If the console returns with the newly installed version of ShowRunnerCLC™, then the installation was successful 86 86 ** If the console returns with "Bad or Incomplete Command (sr)" then the installation was not successful 87 87 *** Rename the downloaded .puf file to be a .zip file and open the archive 88 88 **** Some file archivers (such as 7-Zip) allow you to right click on the PUF file and open the archive without changing the filetype ... ... @@ -91,18 +91,18 @@ 91 91 **** Alternatively, navigate to Functions>SIMPL Program...>SIMPL Program (Program01)... 92 92 *** Under the "Send Program" section, browse your PC and select the extracted .cpz file 93 93 *** Click the "Send" button and click "Yes" to upload the program 94 -*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of S HOWRUNNER™95 -* Once S HOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.96 -** **3-Series processors require authentication enabled** ( SSLself can be used but steps will need to be repeated)100 +*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of ShowRunnerCLC™ 101 +* Once ShowRunnerCLC™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required. 102 +** **3-Series processors require authentication enabled** ("##ssl self##" command followed by a reboot can be used but steps will need to be repeated) 97 97 ** If stuck on "Connecting to Processor" you will need to accept the certificate 98 -* For jobs with multiple processors, S HOWRUNNER™ will need to be loaded to each processor104 +* For jobs with multiple processors, ShowRunnerCLC™ will need to be loaded to each processor 99 99 100 -= ==License and Configuration Deployment ===106 += License and Configuration Deployment = 101 101 102 102 * Download the SrConfig.json or CiLightingConfig.json configuration file from the link provided by Chief Integrations 103 103 * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]] 104 104 ** Processors with a Control Subnet should use the LAN MAC address, **not** the Control Subnet MAC address 105 -* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the showrunnerHUB™ web interface111 +* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the ShowRunnerHUB™ web interface 106 106 ** Using Toolbox: 107 107 *** Connect to the processor via Text Console and via File Management 108 108 *** In File management, navigate to the "NVRAM>sr" folder from the left-hand menu ... ... @@ -112,15 +112,17 @@ 112 112 *** Right-click on the right-hand side and select "Copy File(s) From..." and select the downloaded SrConfig.json file 113 113 **** Alternatively, drag and drop the file from your computer to the File Management tool 114 114 **** If you downloaded a CiLightingConfig.json file, it must be renamed to "SrConfig.json" 115 -** Using the showrunnerHUB™ UI: 121 +*** Note: when loading the license and configuration through Toolbox, the "License.lic" file and "SrConfig.json" file must have exact filenames 122 +**** If the files were automatically numbered during download (e.g. by adding a "(1)" or "(2)" to the end of the filename), the files must be renamed before loading them to the processor 123 +** Using the ShowRunnerHUB™ UI: 116 116 *** Using Chrome or Firefox, navigate to the processor's IP address 117 117 *** When prompted, input your credentials and log in 118 118 **** 4-Series processor or 3-Series processor with authentication enabled: Log in using the same admin credentials used to connect to the processor 119 119 **** 3-Series processor without authentication enabled: Connect to the processor via Text Console and run the following command, replacing the "username", "name" and "password" with your desired credentials. 120 -***** ##sradmin username "name" administrators password##121 -***** The username and password should be one word each and are the credentials used to log in to the showrunnerHUB™122 -***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user .123 -*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page128 +***** ##sradmin add user **username **"**name**" Administrators **password**## 129 +***** The username and password should be one word each and are the credentials used to log in to the ShowRunnerHUB™ 130 +***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user 131 +*** Once logged in to the ShowRunnerHUB™ UI, you should be automatically redirected to the File Management page 124 124 **** If you are not automatically redirected, then you can navigate to this page by clicking "Setup" in the top right and then selecting "File Management" from the list on the left 125 125 **** [[image:1654807593390-193.png]] 126 126 **** Under “Upload New License File” ... ... @@ -138,10 +138,10 @@ 138 138 ****** Enter the secret used to create the backup. ShowRunner will upload the file and verify the secret. 139 139 **** Once both the license and either a configuration file or backup have been loaded, click "Restart" 140 140 **** Wait for the processor to finish restarting and then reload the page. 141 -***** 3-Series processors will take 45 to 90 restart 142 -***** 4-Series processors shouldrestart considerably faster149 +***** 3-Series processors will take 45 to 90 seconds to restart, possibly longer depending on the size and complexity of the configuration 150 +***** 4-Series processors will restart considerably faster 143 143 144 -= ==Set System Time ===152 += Set System Time = 145 145 146 146 It is important for the device clock to be accurate in order for scheduled events to trigger at the appropriate time. If Toolbox is still open, this can be done easily: 147 147 ... ... @@ -152,14 +152,15 @@ 152 152 ** If your PC is in the incorrect Timezone or the time did not synchronize properly, then manually adjust the Time, Date, and Timezone 153 153 * Press the Apply button 154 154 155 -Note that the Location given in the System Clock... menu of Toolbox is not used by S HOWRUNNER™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the SHOWRUNNER™ UI163 +Note that the Location given in the System Clock... menu of Toolbox is not used by ShowRunnerCLC™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the ShowRunnerCLC™ UI 156 156 157 -* S HOWRUNNER™ XPanel UI:165 +* ShowRunnerCLC™ XPanel UI: 158 158 ** Navigate to Settings>Location and System Clock 159 159 ** Press the Lock icon to enable editing 160 160 ** Adjust the time, timezone, and location as necessary 161 161 ** Press Set System Clock to save the changes 162 -* showrunnerHUB™ Web UI:170 +* ShowRunnerHUB™ Web UI: 163 163 ** Navigate to Setup>System Settings>Location and System Clock 164 164 ** Adjust the time, timezone, and location as necessary 165 165 ** Click Apply to save the changes 174 +)))