Changes for page Processor Setup

Last modified by Alexander Mott on 2024/12/02 19:04

From version 24.1
edited by Alexander Mott
on 2022/06/30 16:53
Change comment: There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2022/06/09 22:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.WebHome
1 +SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.WebHome
Content
... ... @@ -1,11 +6,6 @@
1 -(% class="box errormessage" %)
2 -(((
3 -This page is for ordinary processor setup. For ZUM-HUB4 deployments, see our [[dedicated ZUM-HUB4 page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUM-HUB4 Processor Setup.WebHome]].
4 -)))
5 -
6 6  (% class="box warningmessage" %)
7 7  (((
8 -SHOWRUNNER™ is tested against current Crestron firmware releases.  Please use at least the recommended firmware builds.
3 +showrunner is tested against current Crestron firmware releases.  Please use at least the recommended firmware builds.
9 9  3-Series: PUF 1.8001.0146
10 10  4-Series: PUF 2.7000.00052.01
11 11  VC-4: 2.7000.00047
... ... @@ -38,11 +38,11 @@
38 38  **** Once logged into Text Console, run the following commands, replacing the "username" and "password" with your desired credentials
39 39  ***** ##adduser -N:username -P:password##
40 40  ***** ##addusertogroup -N:username -G:Administrators##
41 -** Once connected, open Text Console and run the following commands to configure the processor's IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a processor IP address of (% style="color:blue" %)**10.0.0.10**(%%))
36 +** Once connected, open Text Console and run the following commands to configure the processor's IP settings (example is for a 10.0.0.0/24 subnet, with a processor IP address of 10.0.0.10)
42 42  *** Disable DHCP: ##dhcp 0 off##
43 -*** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.10**(%%)##
44 -*** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)##
45 -*** Set default gateway: ##defr 0 **10.0.0.1**##
38 +*** Set IP address: ##ipa 0 10.0.0.10##
39 +*** Set IP subnet mask: ##ipm 0 255.255.255.0##
40 +*** Set default gateway: ##defr 0 10.0.0.1##
46 46  *** Set hostname: ##host AP3-CPP##
47 47  *** Reboot the processor: ##reboot##
48 48  ** It is also possible to configure a processor over Ethernet by using a DHCP server software on your laptop to assign an IP address
... ... @@ -57,7 +57,7 @@
57 57  ** The Control Subnet can be configured manually in the "Functions>Ethernet Addressing...>Control Subnet" menu of Toolbox
58 58  *** Set routing to "Manual" with the start address and subnet size
59 59  *** E.g., a setting of "10.0.0.0/24" will have the processor at 10.0.0.1 with an IP mask of 255.255.255.0 and a default gateway and DNS server at 10.0.0.2
60 -** The Control Subnet can also be configured to e.g. **10.0.0.0/24** using Text Console command: ##csrouterprefix **10.0.0.0/24**##
55 +** The Control Subnet can also be configured using Text Console command: ##csrouterprefix 10.0.0.0/24##
61 61  * If the job has multiple processors, then these steps must be repeated for all processors on the job
62 62  ** For jobs with Central Control, the IP addresses of the processors matters
63 63  ** Chief Integrations will provide an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists the IP address for each processor. If these IP addresses must be changed during startup, then it will be necessary to also change the IP addresses in the Remote System Definition in the configuration file
... ... @@ -65,8 +65,8 @@
65 65  
66 66  === Program Load ===
67 67  
68 -* Download the latest build of SHOWRUNNER™ from the[[ Chief Integrations Portal>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]]
69 -* Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network
63 +* Download the latest build of SHOWRUNNER™ [[https:~~/~~/files.chiefintegrations.com/s/WHNzXrrZbB5jC3E>>url:https://files.chiefintegrations.com/s/WHNzXrrZbB5jC3E]]
64 +* Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network.
70 70  ** While it is possible to load the program via USB, it is not recommended because the transfer speed is significantly slower than loading via Ethernet
71 71  * Double click the PUF to open the Package Update Tool and install SHOWRUNNER™ (works best with Toolbox closed)
72 72  ** The Package Update Tool will automatically open your Address Book and prompt you to select a device
... ... @@ -81,18 +81,17 @@
81 81  ** Run the command ##sr ver##
82 82  ** If the console returns with the newly installed version of SHOWRUNNER™, then the installation was successful
83 83  ** If the console returns with "Bad or Incomplete Command (sr)" then the installation was not successful
84 -*** Rename the downloaded .puf file to be a .zip file and open the archive
79 +*** Rename the .puf file to be a .zip file and open the archive
85 85  **** Some file archivers (such as 7-Zip) allow you to right click on the PUF file and open the archive without changing the filetype
86 86  *** Extract the "CI.Lighting.ShowRunner.cpz" file
87 -*** In Toolbox, connect to the processor via Text Console, click the lightning bolt icon, and select "SIMPL Program..."
88 -**** Alternatively, navigate to Functions>SIMPL Program...>SIMPL Program (Program01)...
89 -*** Under the "Send Program" section, browse your PC and select the extracted .cpz file
82 +*** In Toolbox, connect to the processor via Text Console and click the lightning bolt icon and select "SIMPL Program..."
83 +*** Under the "Send" section, browse your PC and select the extracted .cpz file
90 90  *** Click the "Send" button and click "Yes" to upload the program
91 91  *** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER™
92 92  * Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required.  
93 -** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated)
94 -** If stuck on "Connecting to Processor" you will need to accept the certificate
95 -* For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor
87 +** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated).
88 +** If stuck on "Connecting to Processor" you will need to accept the certificate.
89 +* For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor.
96 96  
97 97  === License and Configuration Deployment ===
98 98  
... ... @@ -117,7 +117,7 @@
117 117  ***** ##sradmin username "name" administrators password##
118 118  ***** The username and password should be one word each and are the credentials used to log in to the showrunnerHUB™
119 119  ***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user.
120 -*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page
114 +*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page.
121 121  **** If you are not automatically redirected, then you can navigate to this page by clicking "Setup" in the top right and then selecting "File Management" from the list on the left
122 122  **** [[image:1654807593390-193.png]]
123 123  **** Under “Upload New License File”
... ... @@ -137,26 +137,3 @@
137 137  **** Wait for the processor to finish restarting and then reload the page.
138 138  ***** 3-Series processors will take 45 to 90 restart
139 139  ***** 4-Series processors should restart considerably faster
140 -
141 -=== Set System Time ===
142 -
143 -It is important for the device clock to be accurate in order for scheduled events to trigger at the appropriate time. If Toolbox is still open, this can be done easily:
144 -
145 -* Connect to the processor via Text Console
146 -* At the top of the Toolbox window, navigate to Functions>System Clock...
147 -* If your computer is in the correct timezone, click Synchronize Device Time with PC
148 -** The Timezone and Device Time should synchronize automatically
149 -** If your PC is in the incorrect Timezone or the time did not synchronize properly, then manually adjust the Time, Date, and Timezone
150 -* Press the Apply button
151 -
152 -Note that the Location given in the System Clock... menu of Toolbox is not used by SHOWRUNNER™. Instead, the location used for sunrise/sunset calculations is stored in the configuration and will typically be set by Chief Integrations prior to delivery of the configuration. Both the location and time can be viewed and edited using the SHOWRUNNER™ UI
153 -
154 -* SHOWRUNNER™ XPanel UI:
155 -** Navigate to Settings>Location and System Clock
156 -** Press the Lock icon to enable editing
157 -** Adjust the time, timezone, and location as necessary
158 -** Press Set System Clock to save the changes
159 -* showrunnerHUB™ Web UI:
160 -** Navigate to Setup>System Settings>Location and System Clock
161 -** Adjust the time, timezone, and location as necessary
162 -** Click Apply to save the changes