Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 6.2
edited by Alexander Mott
on 2023/12/04 19:24
on 2023/12/04 19:24
Change comment:
There is no comment for this version
To version 6.1
edited by Alexander Mott
on 2023/12/04 18:14
on 2023/12/04 18:14
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,38 +14,28 @@ 14 14 15 15 Whether connected to the CEN-GWEXER via USB or Ethernet, the process to configure the static IP addresses is the same: 16 16 17 -* Open Text Console in Toolbox and connect to the CEN- GWEXER18 -* *Notethatyoumayneed tomanuallyselect"SSL"connectiontype, as"Auto"mightnotalways redirect19 -* Run the following commands to configure the CEN-GWEXER's static IP settings (example is for a**10.0.0.0(%style="color:darkgoldenrod" %)/24(%%)** subnet, with astatic IP address of (% style="color:blue"%)**10.0.0.12**(%%), an IP-IDof (% style="color:olive" %)**C1**(%%), and a target processor IPaddress of (% style="color:orange" %)**10.0.0.10**(%%), anda devicehostname of (% style="color:purple"%)**GWEXER-L1**(%%))17 +* Open Text Console in Toolbox and connect **to the DIN-CENCN-2** 18 +* Run the following commands to configure the DIN-CENCN-2's IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a CENCN-2 IP address of (% style="color:blue" %)**10.0.0.12**(%%), a CENCN-2 IP-ID of (% style="color:olive" %)**D1**(%%), a processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a hostname of (% style="color:purple" %)**CENCN-L1**(%%)) 19 +** Disable DHCP: ##dhcp off## 20 20 ** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.12**(%%)## 21 21 ** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 22 22 ** Set default gateway: ##defr 0 **10.0.0.1**## 23 -** Disable DHCP: ##dhcp off## 24 -** Update IP table: ##addm (% style="color:olive" %)**C1**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 25 -** Set hostname: ##host (% style="color:purple" %)**GWEXER-L1**(%%)## 26 -** Reboot the CEN-GWEXER: ##reboot## 27 -* Repeat for all CEN-GWEXERs on the job 23 +** Update IP table: ##addm (% style="color:olive" %)**D1**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 24 +** Set hostname: ##host (% style="color:purple" %)**CENCN-L1**(%%)## 25 +** Reboot the DIN-CENCN-2: ##reboot## 26 +* Repeat for all DIN-CENCN-2s on the job 28 28 29 29 = SSL Setup = 30 30 31 - Crestron devices that support SSLrequire the useof a secureconnection between the processor and the device. In order to establish this secure connection, the processormust have authentication enabled and there must be a user on the processor with "Connects" group permissions.30 +Lorem 32 32 33 -Configure the Connects user on the processor: 32 +~/~/https:~/~/wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20User%20Guide%20%26%20Wiki/SHOWRUNNER%E2%84%A2%20Appendix/SSL%20User%20Configuration/ 33 +SSL setup on proc 34 +SSL setup on devices 34 34 35 -* Ensure the processor has [[its IP configured and authentication enabled>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HIPConfiguration"]] 36 -** Verify the processor has authentication enabled by running the command: ##auth## without any parameters 37 -* Create a user by running the following commands, replacing the "username" and "password" with your desired credentials 38 -** ##adduser -N:username -P:password## 39 -** ##addusertogroup -N:username -G:Connects## 40 -* Verify that the user has been created by running the command: ##listusers## 41 -* This process only needs to be performed once per processor on the jobsite 36 +~/~/Need to manually set SSL/TSL method for connecting to gwexer with auth enabled 37 +- also need to update address book if gwexer are added to address book (defaults to ctp) 42 42 43 -Configure the CS authentication on the CEN-GWEXER: 44 - 45 -* Run the following command, replacing the "username" and "password" with the credentials of the Connects user from the previous step 46 -** ##setcsauth -N:username -P:password## 47 -* Repeat this process for every CEN-GWEXER on the jobsite 48 - 49 49 = RF Channel = 50 50 51 51 Lorem