Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 5.1
edited by Alexander Mott
on 2023/12/04 17:41
on 2023/12/04 17:41
Change comment:
There is no comment for this version
To version 6.2
edited by Alexander Mott
on 2023/12/04 19:24
on 2023/12/04 19:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,19 +8,44 @@ 8 8 9 9 = IP Configuration = 10 10 11 - Lorem11 +Typically, each CEN-GWEXER will need to be initially configured via USB (micro USB), unless their MAC addresses are already known and the lighting network has a DHCP server (either by running DHCP server software on your computer, or if the processor has a control subnet or is running the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]). 12 12 13 +CEN-GWEXERs for the first time, it may be necessary to manually change the connection type from "Auto" to "SSL" 14 + 15 +Whether connected to the CEN-GWEXER via USB or Ethernet, the process to configure the static IP addresses is the same: 16 + 17 +* Open Text Console in Toolbox and connect to the CEN-GWEXER 18 +** Note that you may need to manually select "SSL" connection type, as "Auto" might not always redirect 19 +* Run the following commands to configure the CEN-GWEXER's static IP settings (example is for a **10.0.0.0(% style="color:darkgoldenrod" %)/24(%%)** subnet, with a static IP address of (% style="color:blue" %)**10.0.0.12**(%%), an IP-ID of (% style="color:olive" %)**C1**(%%), and a target processor IP address of (% style="color:orange" %)**10.0.0.10**(%%), and a device hostname of (% style="color:purple" %)**GWEXER-L1**(%%)) 20 +** Set IP address: ##ipa 0 (% style="color:blue" %)**10.0.0.12**(%%)## 21 +** Set IP subnet mask: ##ipm 0 (% style="color:darkgoldenrod" %)**255.255.255.0**(%%)## 22 +** Set default gateway: ##defr 0 **10.0.0.1**## 23 +** Disable DHCP: ##dhcp off## 24 +** Update IP table: ##addm (% style="color:olive" %)**C1**(%%) (% style="color:orange" %)**10.0.0.10**(%%)## 25 +** Set hostname: ##host (% style="color:purple" %)**GWEXER-L1**(%%)## 26 +** Reboot the CEN-GWEXER: ##reboot## 27 +* Repeat for all CEN-GWEXERs on the job 28 + 13 13 = SSL Setup = 14 14 15 -Lorem 31 +Crestron devices that support SSL require the use of a secure connection between the processor and the device. In order to establish this secure connection, the processor must have authentication enabled and there must be a user on the processor with "Connects" group permissions. 16 16 17 -~/~/https:~/~/wiki.chiefintegrations.com/SHOWRUNNER%E2%84%A2%20User%20Guide%20%26%20Wiki/SHOWRUNNER%E2%84%A2%20Appendix/SSL%20User%20Configuration/ 18 -SSL setup on proc 19 -SSL setup on devices 33 +Configure the Connects user on the processor: 20 20 21 -~/~/Need to manually set SSL/TSL method for connecting to gwexer with auth enabled 22 -- also need to update address book if gwexer are added to address book (defaults to ctp) 35 +* Ensure the processor has [[its IP configured and authentication enabled>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HIPConfiguration"]] 36 +** Verify the processor has authentication enabled by running the command: ##auth## without any parameters 37 +* Create a user by running the following commands, replacing the "username" and "password" with your desired credentials 38 +** ##adduser -N:username -P:password## 39 +** ##addusertogroup -N:username -G:Connects## 40 +* Verify that the user has been created by running the command: ##listusers## 41 +* This process only needs to be performed once per processor on the jobsite 23 23 43 +Configure the CS authentication on the CEN-GWEXER: 44 + 45 +* Run the following command, replacing the "username" and "password" with the credentials of the Connects user from the previous step 46 +** ##setcsauth -N:username -P:password## 47 +* Repeat this process for every CEN-GWEXER on the jobsite 48 + 24 24 = RF Channel = 25 25 26 26 Lorem