Changes for page Crestron RF Gateway Setup

Last modified by Alexander Mott on 2025/03/12 17:16

From version 29.1
edited by Alexander Mott
on 2024/12/16 23:38
Change comment: There is no comment for this version
To version 30.1
edited by Alexander Mott
on 2024/12/16 23:40
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -10,7 +10,7 @@
10 10  
11 11  Installations using infinetEX or Extended Range devices require the CEN-GWEXER gateway, while Zūm Wireless installations require the ZUMNET-GATEWAY. Throughout this article, "CEN-GWEXER" and "infinetEX" will be used to refer to the gateway and the wireless devices respectively.
12 12  
13 -For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. CEN-GWEXERs will typically have IP-IDs in the "##Cx##" range. For Zūm Wireless jobs using the [[Zūm Discovery process>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome]], no takeoff is provided as the ZUMNET-GATEWAY IP table will be assigned and consumed at the time of discovery.
13 +For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. CEN-GWEXERs will typically have IP-IDs in the "##Cx##" range. For Zūm Wireless jobs using the [[Zūm Discovery process>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome]], the IP table portion of the IP Configuration should be skipped as the ZUMNET-GATEWAY IP table will be assigned and consumed at the time of discovery.
14 14  
15 15  = IP Configuration =
16 16  
... ... @@ -51,6 +51,7 @@
51 51  ** Note that you may need to manually select "SSL" connection type, as "Auto" might not always redirect
52 52  * Run the following commands to configure the CEN-GWEXER's IP table and hostname (example is for an IP-ID of (% style="color:olive" %)**C1**(%%), and a target processor IP address of (% style="color:orange" %)**172.22.0.1**(%%), and a device hostname of (% style="color:purple" %)**GWEXER-L1**(%%))
53 53  ** Update IP table: ##addm (% style="color:olive" %)**C1**(%%) (% style="color:orange" %)**172.22.0.1**(%%)##
54 +*** Skip for [[Zūm Discovery jobs>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Zūm Discovery.WebHome]]: IP table is automatically assigned at time of discovery
54 54  ** Set hostname: ##host (% style="color:purple" %)**GWEXER-L1**(%%)##
55 55  ** Reboot the CEN-GWEXER: ##reboot##
56 56  * At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]]