Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 24.1
edited by Alexander Mott
on 2024/10/24 17:44
on 2024/10/24 17:44
Change comment:
There is no comment for this version
To version 23.1
edited by Alexander Mott
on 2024/10/24 17:34
on 2024/10/24 17:34
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -C restronRFGatewaySetup1 +CEN-GWEXER Setup - Content
-
... ... @@ -2,10 +2,8 @@ 2 2 {{toc/}} 3 3 {{/box}} 4 4 5 -C restron RFGateways are a two-way radiofrequency (RF) transceivers that allow CrestronZūm Wireless (ZUMMESH), infinetEX,orExtended Range wireless devices to communicate with the control processor over Ethernet. They are for Crestron wireless systems what [[DIN-CENCN-2s>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.DIN-CENCN-2 Setup.WebHome]] are for wired Cresnet systems.5 +CEN-GWEXERs are a two-way radiofrequency (RF) transceivers that allow Crestron infinetEX and Extended Range wireless devices to communicate with the control processor over Ethernet. They are for Crestron wireless systems what [[DIN-CENCN-2s>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.DIN-CENCN-2 Setup.WebHome]] are for wired Cresnet systems. 6 6 7 -Installations using infinetEX or Extended Range devices require the CEN-GWEXER gateway, while Zūm Wireless installations require the ZUMNET-GATEWAY. Throughout this article, "CEN-GWEXER" and "infinetEX" will be used to refer to the gateway and the wireless devices respectively. 8 - 9 9 For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. CEN-GWEXERs will typically have IP-IDs in the "##Cx##" range. 10 10 11 11 = IP Configuration =