Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 21.1
edited by Alexander Mott
on 2024/10/24 17:14
on 2024/10/24 17:14
Change comment:
There is no comment for this version
To version 24.1
edited by Alexander Mott
on 2024/10/24 17:44
on 2024/10/24 17:44
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -C EN-GWEXER Setup1 +Crestron RF Gateway Setup - Content
-
... ... @@ -2,10 +2,12 @@ 2 2 {{toc/}} 3 3 {{/box}} 4 4 5 -C EN-GWEXERs are a two-way radiofrequency (RF) transceivers that allow Crestron infinetEXandExtended Range wireless devices to communicate with the control processor over Ethernet. They are for Crestron wireless systems what [[DIN-CENCN-2s>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.DIN-CENCN-2 Setup.WebHome]] are for wired Cresnet systems.5 +Crestron RF Gateways are a two-way radiofrequency (RF) transceivers that allow Crestron Zūm Wireless (ZUMMESH), infinetEX, or Extended Range wireless devices to communicate with the control processor over Ethernet. They are for Crestron wireless systems what [[DIN-CENCN-2s>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.DIN-CENCN-2 Setup.WebHome]] are for wired Cresnet systems. 6 6 7 - For SHOWRUNNER™ installations,the IP address of the CEN-GWEXER doesnot matter as longasitis inthesame range astheprocessoranddoesnot conflict withany otherdeviceson thenetwork.Instead,CEN-GWEXERsare identifiedto theprocessorviatheir IP-ID. Note thatwhich infinetEXdevices arelanded atwhichCEN-GWEXERmatters,andif devices are moved betweenCEN-GWEXERsthenthe configuration willneed tobe updated(see below).ChiefIntegrationstypically providesan SRTakeoff.xlsx spreadsheetwithan IP Tabletabthatlistsall the CEN-GWEXER IP-IDs in theprogram. If no takeoffis provided, then the processor'sIP table can be checkedby running the##ipt -t ##command from theprocessor after theconfiguration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Cx##" range.7 +Installations using infinetEX or Extended Range devices require the CEN-GWEXER gateway, while Zūm Wireless installations require the ZUMNET-GATEWAY. Throughout this article, "CEN-GWEXER" and "infinetEX" will be used to refer to the gateway and the wireless devices respectively. 8 8 9 +For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. CEN-GWEXERs will typically have IP-IDs in the "##Cx##" range. 10 + 9 9 = IP Configuration = 10 10 11 11 Typically, each CEN-GWEXER will need to be initially configured via USB (microUSB) unless their MAC addresses are already known and the lighting network has a DHCP server. If the DHCP server on the network is temporary (e.g. DHCP server software running on your computer or a processor utilizing the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]), then static IP addresses must be configured. If the DHCP server is permanent (such as a CP4N or ZUM-HUB4 Control Subnet), then only the IP table needs to be configured for the devices. ... ... @@ -50,6 +50,8 @@ 50 50 * At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 51 51 * Repeat for all CEN-GWEXERs on the job 52 52 55 +If setup has been done correctly and the ShowRunnerCLC™ program and configuration have already been loaded to the processor, then you should see the CEN-GWEXER's IP-ID reporting online when you run the ##ipt## command on both the CEN-IO and the processor. 56 + 53 53 == Static Configuration == 54 54 55 55 (% class="box warningmessage" %) ... ... @@ -72,6 +72,8 @@ 72 72 * At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 73 73 * Repeat for all CEN-GWEXERs on the job 74 74 79 +If setup has been done correctly and the ShowRunnerCLC™ program and configuration have already been loaded to the processor, then you should see the CEN-GWEXER's IP-ID reporting online when you run the ##ipt## command on both the CEN-IO and the processor. 80 + 75 75 = RF Channel = 76 76 77 77 Crestron wireless devices have 16 non-overlapping channels numbered 11-26 to prevent and avoid RF interference either from other appliances in the building (such as microwaves or Wi-Fi routers) or from other Crestron devices that are attempting to communicate with different CEN-GWEXERs.