Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 20.1
edited by Alexander Mott
on 2024/02/16 20:21
on 2024/02/16 20:21
Change comment:
There is no comment for this version
To version 23.1
edited by Alexander Mott
on 2024/10/24 17:34
on 2024/10/24 17:34
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,7 +4,7 @@ 4 4 5 5 CEN-GWEXERs are a two-way radiofrequency (RF) transceivers that allow Crestron infinetEX and Extended Range wireless devices to communicate with the control processor over Ethernet. They are for Crestron wireless systems what [[DIN-CENCN-2s>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.DIN-CENCN-2 Setup.WebHome]] are for wired Cresnet systems. 6 6 7 -For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Cx##" range.7 +For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. CEN-GWEXERs will typically have IP-IDs in the "##Cx##" range. 8 8 9 9 = IP Configuration = 10 10 ... ... @@ -50,6 +50,8 @@ 50 50 * At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 51 51 * Repeat for all CEN-GWEXERs on the job 52 52 53 +If setup has been done correctly and the ShowRunnerCLC™ program and configuration have already been loaded to the processor, then you should see the CEN-GWEXER's IP-ID reporting online when you run the ##ipt## command on both the CEN-IO and the processor. 54 + 53 53 == Static Configuration == 54 54 55 55 (% class="box warningmessage" %) ... ... @@ -72,6 +72,8 @@ 72 72 * At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 73 73 * Repeat for all CEN-GWEXERs on the job 74 74 77 +If setup has been done correctly and the ShowRunnerCLC™ program and configuration have already been loaded to the processor, then you should see the CEN-GWEXER's IP-ID reporting online when you run the ##ipt## command on both the CEN-IO and the processor. 78 + 75 75 = RF Channel = 76 76 77 77 Crestron wireless devices have 16 non-overlapping channels numbered 11-26 to prevent and avoid RF interference either from other appliances in the building (such as microwaves or Wi-Fi routers) or from other Crestron devices that are attempting to communicate with different CEN-GWEXERs.