Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 2.1
edited by Alexander Mott
on 2023/07/10 14:55
on 2023/07/10 14:55
Change comment:
There is no comment for this version
To version 2.3
edited by Alexander Mott
on 2023/12/04 16:52
on 2023/12/04 16:52
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - *CEN-GWEXER Setup1 +CEN-GWEXER Setup - Content
-
... ... @@ -2,28 +2,30 @@ 2 2 {{toc/}} 3 3 {{/box}} 4 4 5 - Lorem ipsumdolorsitamet,consecteturdipiscingelit, seddo eiusmodtempor incididunt ut laboreetdolore magnaaliqua. Utim adminim veniam,quisnostrudexercitationullamcolaborisnisi utaliquipexeacommodoconsequat.Duis auteiruredolorinreprehenderitin voluptatevelitessecillum doloreeufugiatnullapariatur.xcepteursintoccaecatcupidatat nonproident,suntin culpaquiofficia deseruntmollitanim id estlaborum.5 +CEN-GWEXERs are a two-way radiofrequency (RF) transceivers that allow Crestron infinetEX and Extended Range wireless devices to communicate with the control processor over Ethernet. They are for Crestron wireless systems what [[DIN-CENCN-2s>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.DIN-CENCN-2 Setup.WebHome]] are for wired Cresnet systems. 6 6 7 - =Initial Connection=7 +For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Cx##" range. 8 8 9 - Lorem9 += IP Configuration = 10 10 11 -== IP Configuration == 12 - 13 13 Lorem 14 14 15 -= =Sub2==13 += SSL Setup = 16 16 17 17 Lorem 18 18 19 -= OtherNotes=17 += RF Channel = 20 20 21 21 Lorem 22 22 23 -= =RFChannel==21 += Useful Commands and Other Notes = 24 24 25 25 Lorem 26 26 27 -== Unacquiring Devices ==25 +== Acquiring Devices == 28 28 29 29 Lorem 28 + 29 +== Moving/Removing Devices (Unacquiring Devices) == 30 + 31 +When a wireless Crestron device is acquired to a new gateway using the typical acquiring process described above, it will automatically forget the previously connected gateway. The gateway itself, however, must manually "forget" the previously connected device before a newly acquired and addressed device will function correctly. This is necessary whether the originally connected device is moved or if the originally corrected device has failed and is being replaced.