... ... @@ -4,7 +4,7 @@
4 4  
5 5  CEN-GWEXERs are a two-way radiofrequency (RF) transceivers that allow Crestron infinetEX and Extended Range wireless devices to communicate with the control processor over Ethernet. They are for Crestron wireless systems what [[DIN-CENCN-2s>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.DIN-CENCN-2 Setup.WebHome]] are for wired Cresnet systems.
6 6  
7 -For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. DIN-CENCN-2's will typically have IP-IDs in the "##Cx##" range.
7 +For SHOWRUNNER™ installations, the IP address of the CEN-GWEXER does not matter as long as it is in the same range as the processor and does not conflict with any other devices on the network. Instead, CEN-GWEXERs are identified to the processor via their IP-ID. Note that which infinetEX devices are landed at which CEN-GWEXER matters, and if devices are moved between CEN-GWEXERs then the configuration will need to be updated (see below). Chief Integrations typically provides an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists all the CEN-GWEXER IP-IDs in the program. If no takeoff is provided, then the processor's IP table can be checked by running the ##ipt -t ##command from the processor after the configuration is loaded. CEN-GWEXERs will typically have IP-IDs in the "##Cx##" range.
8 8  
9 9  = IP Configuration =
10 10  
... ... @@ -14,7 +14,7 @@
14 14  
15 15  == SSL Setup ==
16 16  
17 -Crestron devices that support SSL require the use of a secure connection between the processor and the device. In order to establish this secure connection, the processor must have authentication enabled and there must be a user on the processor with "Connects" group permissions.
17 +Crestron devices that support SSL require the use of a secure connection between the processor and the device. In order to establish this secure connection, the processor must have authentication enabled and there must be a user on the processor with "Connects" group permissions. The device connecting to the processor must be configured to use these credentials before the processor is added to the IP table, otherwise the device's IP address will be blocked by the processor (see [[our FAQ on how to resolve this>>attach:https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20processor%20via%20Ethernet]])
18 18  
19 19  Configure the Connects user on the processor:
20 20  
... ... @@ -34,6 +34,11 @@
34 34  
35 35  == DHCP Configuration ==
36 36  
37 +(% class="box warningmessage" %)
38 +(((
39 +Be sure to complete the above SSL Setup prior to setting the IP table
40 +)))
41 +
37 37  If the lighting network has a permanent DHCP server, then CEN-GWEXERs only require their IP table to be configured, though it is good practice to also record or update their hostname. If the MAC addresses for the CEN-GWEXERs are not known, then the best way to update their configuration is via USB (microUSB). If you are able to identify the CEN-GWEXERs by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected to the CEN-GWEXER via USB or Ethernet, the process to configure the IP table and hostname is the same:
38 38  
39 39  * Open Text Console in Toolbox and connect to the CEN-GWEXER
... ... @@ -47,6 +47,11 @@
47 47  
48 48  == Static Configuration ==
49 49  
55 +(% class="box warningmessage" %)
56 +(((
57 +Be sure to complete the above SSL Setup prior to setting the IP table
58 +)))
59 +
50 50  If there is no permanent DHCP server on the lighting network, then CEN-GWEXERs should be configured with static IP addresses via USB (micro USB). If a temporary DHCP server is connected to the lighting network and you are able to identify CEN-GWEXERs by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected via USB or Ethernet, the process to configure the static IP addresses is the same:
51 51  
52 52  * Open Text Console in Toolbox and connect to the CEN-GWEXER