Changes for page Crestron RF Gateway Setup

Last modified by Alexander Mott on 2025/03/12 17:16

From version 19.1
edited by Alexander Mott
on 2024/02/16 20:14
Change comment: There is no comment for this version
To version 20.1
edited by Alexander Mott
on 2024/02/16 20:21
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,7 +14,7 @@
14 14  
15 15  == SSL Setup ==
16 16  
17 -Crestron devices that support SSL require the use of a secure connection between the processor and the device. In order to establish this secure connection, the processor must have authentication enabled and there must be a user on the processor with "Connects" group permissions.
17 +Crestron devices that support SSL require the use of a secure connection between the processor and the device. In order to establish this secure connection, the processor must have authentication enabled and there must be a user on the processor with "Connects" group permissions. The device connecting to the processor must be configured to use these credentials before the processor is added to the IP table, otherwise the device's IP address will be blocked by the processor (see [[our FAQ on how to resolve this>>attach:https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20processor%20via%20Ethernet]])
18 18  
19 19  Configure the Connects user on the processor:
20 20  
... ... @@ -34,6 +34,11 @@
34 34  
35 35  == DHCP Configuration ==
36 36  
37 +(% class="box warningmessage" %)
38 +(((
39 +Be sure to complete the above SSL Setup prior to setting the IP table
40 +)))
41 +
37 37  If the lighting network has a permanent DHCP server, then CEN-GWEXERs only require their IP table to be configured, though it is good practice to also record or update their hostname. If the MAC addresses for the CEN-GWEXERs are not known, then the best way to update their configuration is via USB (microUSB). If you are able to identify the CEN-GWEXERs by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected to the CEN-GWEXER via USB or Ethernet, the process to configure the IP table and hostname is the same:
38 38  
39 39  * Open Text Console in Toolbox and connect to the CEN-GWEXER
... ... @@ -47,6 +47,11 @@
47 47  
48 48  == Static Configuration ==
49 49  
55 +(% class="box warningmessage" %)
56 +(((
57 +Be sure to complete the above SSL Setup prior to setting the IP table
58 +)))
59 +
50 50  If there is no permanent DHCP server on the lighting network, then CEN-GWEXERs should be configured with static IP addresses via USB (micro USB). If a temporary DHCP server is connected to the lighting network and you are able to identify CEN-GWEXERs by MAC address, then it is possible to configure these settings via Ethernet using Text Console. Whether connected via USB or Ethernet, the process to configure the static IP addresses is the same:
51 51  
52 52  * Open Text Console in Toolbox and connect to the CEN-GWEXER