Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 19.1
edited by Alexander Mott
on 2024/02/16 20:14
on 2024/02/16 20:14
Change comment:
There is no comment for this version
To version 15.1
edited by Alexander Mott
on 2024/02/09 00:54
on 2024/02/09 00:54
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - false1 +true - Content
-
... ... @@ -8,34 +8,15 @@ 8 8 9 9 = IP Configuration = 10 10 11 -Typically, each CEN-GWEXER will need to be initially configured via USB (microUSB) unless their MAC addresses are already known and the lighting network has a DHCP server. If the DHCP server on the network is temporary (e.g. DHCP server software running on your computer or a processor utilizing the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]), then static IP addresses must be configured. If the DHCP server is permanent (such as a CP4N or ZUM-HUB4 Control Subnet), then only the IP table needs to be configured for the devices. 11 +Typically, each CEN-GWEXER will need to be initially configured via USB (micro USB) unless their MAC addresses are already known and the lighting network has a DHCP server. If the DHCP server on the network is temporary (e.g. DHCP server software running on your computer or a processor utilizing the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]), then static IP addresses must be configured. If the DHCP server is permanent (such as a CP4N or ZUM-HUB4 Control Subnet), then only the IP table needs to be configured for the devices. 12 12 13 13 When connecting to a CEN-GWEXER for the first time, it may be necessary to manually change the connection type from "Auto" to "SSL/TLS". It is also necessary to manually edit the CEN-GWEXER's address book entry so that the connection protocol is "SSL/TLS" when a CEN-GWEXER is added to the address book using Device Discovery tool export. 14 14 15 -== SSL Setup == 16 - 17 -Crestron devices that support SSL require the use of a secure connection between the processor and the device. In order to establish this secure connection, the processor must have authentication enabled and there must be a user on the processor with "Connects" group permissions. 18 - 19 -Configure the Connects user on the processor: 20 - 21 -* Ensure the processor has [[its IP configured and authentication enabled>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HIPConfiguration"]] 22 -** Verify the processor has authentication enabled by running the command: ##auth## without any parameters 23 -* Create a user by running the following commands, replacing the "username" and "password" with your desired credentials 24 -** ##adduser -N:username -P:password## 25 -** ##addusertogroup -N:username -G:Connects## 26 -* Verify that the user has been created by running the command: ##listusers## 27 -* This process only needs to be performed once per processor on the jobsite 28 - 29 -Configure the CS authentication on the CEN-GWEXER: 30 - 31 -* Run the following command, replacing the "username" and "password" with the credentials of the Connects user from the previous step 32 -** ##setcsauth -N:username -P:password## 33 -* Repeat this process for every CEN-GWEXER on the jobsite 34 - 35 35 == DHCP Configuration == 36 36 37 -If the lighting network has a permanent DHCP server,then CEN-GWEXERsonlyrequiretheir IP table to be configured,thoughit isgoodpractice toalsorecord orupdateheirhostname. IftheMACaddressesfor the CEN-GWEXERs arenotknown,thenthebest wayto updatetheirconfigurationis via USB (microUSB).If youare ableoidentifytheCEN-GWEXERs by MACaddress,thenit is possibleto configurehesesettingsvia Ethernet using TextConsole.Whether connectedto theCEN-GWEXER viaUSB or Ethernet,the process to configurethe IP table and hostnameisthesame:17 +If the lighting network is a managed network with a permanent DHCP server (or if it is on the Control Subnet of a CP4N, ZUM-HUB4, or other Crestron processor with a dedicated Control Subnet), then the hardware can be left in DHCP mode and only the IP table and hostname should be updated: 38 38 19 +* Connect to the CEN-GWEXER via Ethernet or USB (process is the same either way) 39 39 * Open Text Console in Toolbox and connect to the CEN-GWEXER 40 40 ** Note that you may need to manually select "SSL" connection type, as "Auto" might not always redirect 41 41 * Run the following commands to configure the CEN-GWEXER's IP table and hostname (example is for an IP-ID of (% style="color:olive" %)**C1**(%%), and a target processor IP address of (% style="color:orange" %)**172.22.0.1**(%%), and a device hostname of (% style="color:purple" %)**GWEXER-L1**(%%)) ... ... @@ -62,6 +62,26 @@ 62 62 * At this point, it is a good idea to [[update the device firmware>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome]] 63 63 * Repeat for all CEN-GWEXERs on the job 64 64 46 += SSL Setup = 47 + 48 +Crestron devices that support SSL require the use of a secure connection between the processor and the device. In order to establish this secure connection, the processor must have authentication enabled and there must be a user on the processor with "Connects" group permissions. 49 + 50 +Configure the Connects user on the processor: 51 + 52 +* Ensure the processor has [[its IP configured and authentication enabled>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HIPConfiguration"]] 53 +** Verify the processor has authentication enabled by running the command: ##auth## without any parameters 54 +* Create a user by running the following commands, replacing the "username" and "password" with your desired credentials 55 +** ##adduser -N:username -P:password## 56 +** ##addusertogroup -N:username -G:Connects## 57 +* Verify that the user has been created by running the command: ##listusers## 58 +* This process only needs to be performed once per processor on the jobsite 59 + 60 +Configure the CS authentication on the CEN-GWEXER: 61 + 62 +* Run the following command, replacing the "username" and "password" with the credentials of the Connects user from the previous step 63 +** ##setcsauth -N:username -P:password## 64 +* Repeat this process for every CEN-GWEXER on the jobsite 65 + 65 65 = RF Channel = 66 66 67 67 Crestron wireless devices have 16 non-overlapping channels numbered 11-26 to prevent and avoid RF interference either from other appliances in the building (such as microwaves or Wi-Fi routers) or from other Crestron devices that are attempting to communicate with different CEN-GWEXERs.