Changes for page Crestron RF Gateway Setup
Last modified by Alexander Mott on 2025/03/12 17:16
From version 16.1
edited by Alexander Mott
on 2024/02/09 00:58
on 2024/02/09 00:58
Change comment:
There is no comment for this version
To version 15.1
edited by Alexander Mott
on 2024/02/09 00:54
on 2024/02/09 00:54
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,14 +8,15 @@ 8 8 9 9 = IP Configuration = 10 10 11 -Typically, each CEN-GWEXER will need to be initially configured via USB (microUSB) unless their MAC addresses are already known and the lighting network has a DHCP server. If the DHCP server on the network is temporary (e.g. DHCP server software running on your computer or a processor utilizing the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]), then static IP addresses must be configured. If the DHCP server is permanent (such as a CP4N or ZUM-HUB4 Control Subnet), then only the IP table needs to be configured for the devices. 11 +Typically, each CEN-GWEXER will need to be initially configured via USB (micro USB) unless their MAC addresses are already known and the lighting network has a DHCP server. If the DHCP server on the network is temporary (e.g. DHCP server software running on your computer or a processor utilizing the [[ShowRunner™ DHCP Server>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.DHCP Server.WebHome]]), then static IP addresses must be configured. If the DHCP server is permanent (such as a CP4N or ZUM-HUB4 Control Subnet), then only the IP table needs to be configured for the devices. 12 12 13 13 When connecting to a CEN-GWEXER for the first time, it may be necessary to manually change the connection type from "Auto" to "SSL/TLS". It is also necessary to manually edit the CEN-GWEXER's address book entry so that the connection protocol is "SSL/TLS" when a CEN-GWEXER is added to the address book using Device Discovery tool export. 14 14 15 15 == DHCP Configuration == 16 16 17 -If the lighting network has a permanent DHCP server,then CEN-GWEXERsonlyrequiretheir IP table to be configured,thoughit isgoodpractice toalsorecord orupdateheirhostname. IftheMACaddressesfor the CEN-GWEXERs arenotknown,thenthebest wayto updatetheirconfigurationis via USB (microUSB).If youare ableoidentifytheCEN-GWEXERs by MACaddress,thenit is possibleto configurehesesettingsvia Ethernet using TextConsole.Whether connectedto theCEN-GWEXER viaUSB or Ethernet,the process to configurethe IP table and hostnameisthesame:17 +If the lighting network is a managed network with a permanent DHCP server (or if it is on the Control Subnet of a CP4N, ZUM-HUB4, or other Crestron processor with a dedicated Control Subnet), then the hardware can be left in DHCP mode and only the IP table and hostname should be updated: 18 18 19 +* Connect to the CEN-GWEXER via Ethernet or USB (process is the same either way) 19 19 * Open Text Console in Toolbox and connect to the CEN-GWEXER 20 20 ** Note that you may need to manually select "SSL" connection type, as "Auto" might not always redirect 21 21 * Run the following commands to configure the CEN-GWEXER's IP table and hostname (example is for an IP-ID of (% style="color:olive" %)**C1**(%%), and a target processor IP address of (% style="color:orange" %)**172.22.0.1**(%%), and a device hostname of (% style="color:purple" %)**GWEXER-L1**(%%))