... ... @@ -150,8 +150,6 @@
150 150  
151 151  In order to control DMX fixtures on a Pharos controller with ShowRunner™, it is necessary to make sure that the ShowRunner™ configuration has the correct settings for the Pharos controller. Under the "LightingControllers" section of the ShowRunner™ configuration, locate the entry for the Pharos controller. Under the "Properties" section, verify that the "IpAddressOrHostname" matches the IP address or hostname of the Pharos controller. The "ApiPort" only needs to be changed if the HTTP port for the Pharos controller's web server has been changed from the default 80. Once the Properties for all Pharos controllers have been updated, load the configuration to the processor.
152 152  
153 -== Define Pharos Loads in ShowRunner™ ==
154 -
155 155  Control Pharos groups with ShowRunner™, it is necessary to define them as loads in the ShowRunner™ configuration. To do this using the XPanel UI, navigate to the Settings > Load Configuration page and then select the Pharos controller from the list of controllers on the left. Once the controller is selected, press the "Configure Loads" button:
156 156  
157 157  * Currently defined loads are shown in the list on the left
... ... @@ -176,10 +176,8 @@
176 176  ** If controlling the RGB and White channels of an RGBW fixture separately, then you must define an RGB type load associated with the RGB fixture group in Pharos and then a Single Channel type load associated with the White fixture group in Pharos
177 177  ** The Area Assignment dictates what area the load will be associated with
178 178  
179 -== Scene Mapping ==
177 +ShowRunner™ is also capable of triggering Timelines in the Pharos project. This can be configured using the XPanel UI:
180 180  
181 -ShowRunner™ is also capable of triggering Timelines in the Pharos project by mapping Pharos Timelines to ShowRunner™ Scenes. This can be configured using the XPanel UI:
182 -
183 183  1. Navigate to Settings > Load Hardware
184 184  1. Select the Pharos controller from the list of load controllers on the left
185 185  1. Press "Configure Scene Tracking"
... ... @@ -195,11 +195,7 @@
195 195  
196 196  Some things to consider if you are triggering Pharos Timelines with ShowRunner™:
197 197  
198 -* Since Scene Mapping will directly trigger Pharos Timelines, any Pharos fixture that is part of the Timeline will be affected
199 -** Pharos Groups that are mapped to ShowRunner™ loads in other areas or Pharos Groups that are not defined in ShowRunner™ at all will still be affected if they are part of the Timeline
200 200  * If Scene Tracking is configured for a ShowRunner™ Area, the Pharos Timeline will be triggered regardless of whether any loads are assigned to the Area
201 -* If Scene Tracking is configured for a ShowRunner™ Area, then recalling //any// Scene on the Area will release (stop) //all// Timelines that are associated with the Area before triggering any new Timelines associated with the Scene
202 -** If the Scene being recalled does not have any Timeline  associated with it, any Timelines associated with the area are still released
203 203  * Scene recalls are still executed even if Scene Tracking is enabled
204 204  ** Non-DMX loads in an area with Scene Tracking will still go to their predefined scene levels unless they are excluded from the scene
205 205  ** Pharos DMX loads will go to their predefined scene levels unless they are excluded from the scene, even if they are included in the Pharos Timeline being triggered