Changes for page Pharos Configuration
Last modified by Alexander Mott on 2024/02/26 15:10
From version 31.1
edited by Alexander Mott
on 2023/05/16 21:13
on 2023/05/16 21:13
Change comment:
Uploaded new attachment "lyout-2_text.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -224,20 +224,11 @@ 224 224 225 225 1. Ensure that the controller in the project you wish to address fixtures for has been assigned a live (currently online) controller and that the project has been uploaded to the live controller 226 226 1. Open the project in Designer 2 and navigate to the "Patch" page 227 -1. Select the controller that you wish to address devices for228 -1. Press the "Discover" button that corresponds to the output that you want to address devices for227 +1. Select the controller that you wish to address fixtures for 228 +1. Press the "Discover" button that corresponds to the output that you want to address fixtures for 229 229 1*. Single-universe LPCs have separate "Discover" buttons corresponding to each of the two DMX outputs 230 230 1*. Multi-universe LPCs and EDNs typically have a single "Discover" button for each universe, as there is a 1-to-1 relationship between the output and the universe 231 -1. A window will appear and list all discovered devices, along with a unique device ID, manufacturer/model information, personality (control mode), footprint (number of required addresses), and their current start address 232 -1*. Due to manufacturer compatibility issues, some RDM-capable devices may not appear online, and available information (such as personality) may be incomplete for those devices that are online 233 -1*. Non-driver devices (such as splitters) will appear in the list, but it will not be possible to change their start address 234 -1*. In cases where RDM capable devices do not appear online, they must be addressed manually as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]] 235 -1. Click the "Identify" button and then select the device from the list of available devices in order to identify a specific RDM device 236 -1*. The device should identify itself by flashing any attached loads (if a driver), or by flashing indicator LEDs (if it is another type of device, such as a splitter) 237 -1. To change a device's start address, double-click its start address and type the new start address 238 -1. Once all devices have been identified and re-addressed, click the "Discover" button to refresh the list and verify that no new devices appear online 239 -1. Repeat steps 3 through 8 for all controllers 240 -1. If discovering on all outputs of all controllers does not reveal all the expected drivers, then it may be necessary to manually address drivers as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]] and move on to troubleshooting the DMX installation 231 +1. A window will appear and list all discovered fixtures, along with a unique device ID, manufacturer/model information, personality (control mode) 241 241 242 242 == Address Verification == 243 243
- lyout-2_text.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -177.3 KB - Content