224 224  
225 225  1. Ensure that the controller in the project you wish to address fixtures for has been assigned a live (currently online) controller and that the project has been uploaded to the live controller
226 226  1. Open the project in Designer 2 and navigate to the "Patch" page
227 -1. Select the controller that you wish to address devices for
228 -1. Press the "Discover" button that corresponds to the output that you want to address devices for
227 +1. Select the controller that you wish to address fixtures for
228 +1. Press the "Discover" button that corresponds to the output that you want to address fixtures for
229 229  1*. Single-universe LPCs have separate "Discover" buttons corresponding to each of the two DMX outputs
230 230  1*. Multi-universe LPCs and EDNs typically have a single "Discover" button for each universe, as there is a 1-to-1 relationship between the output and the universe
231 -1. A window will appear and list all discovered devices, along with a unique device ID, manufacturer/model information, personality (control mode), footprint (number of required addresses), and their current start address
232 -1*. Due to manufacturer compatibility issues, some RDM-capable devices may not appear online, and available information (such as personality) may be incomplete for those devices that are online
233 -1*. Non-driver devices (such as splitters) will appear in the list, but it will not be possible to change their start address
234 -1*. In cases where RDM capable devices do not appear online, they must be addressed manually as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]]
235 -1. Click the "Identify" button and then select the device from the list of available devices in order to identify a specific RDM device
236 -1*. The device should identify itself by flashing any attached loads (if a driver), or by flashing indicator LEDs (if it is another type of device, such as a splitter)
237 -1. To change a device's start address, double-click its start address and type the new start address
238 -1. Once all devices have been identified and re-addressed, click the "Discover" button to refresh the list and verify that no new devices appear online
239 -1. Repeat steps 3 through 8 for all controllers
240 -1. If discovering on all outputs of all controllers does not reveal all the expected drivers, then it may be necessary to manually address drivers as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]] and move on to troubleshooting the DMX installation
231 +1. A window will appear and list all discovered fixtures, along with a unique device ID, manufacturer/model information, personality (control mode)