... ... @@ -229,7 +229,8 @@
229 229  1*. Single-universe LPCs have separate "Discover" buttons corresponding to each of the two DMX outputs
230 230  1*. Multi-universe LPCs and EDNs typically have a single "Discover" button for each universe, as there is a 1-to-1 relationship between the output and the universe
231 231  1. A window will appear and list all discovered fixtures, along with a unique device ID, manufacturer/model information, personality (control mode), footprint (number of required addresses), and their current start address
232 -1*. Due to manufacturer compatibility issues, some or most RDM fixtures will not appear online, and available information may be incomplete for those fixtures that are online
232 +1*. Due to manufacturer compatibility issues, some RDM-capable fixtures may not appear online, and available information (such as personality) may be incomplete for those fixtures that are online
233 +1*. In cases where RDM capable fixtures do not appear online, they must be addressed manually as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]]
233 233  1.
234 234  