... ... @@ -43,6 +43,8 @@ 43 43 1. Select "Controller 1" and verify that the number of universes in the "Properties" menu matches the controller that was ordered for the job 44 44 1. If required, click the "New Controller..." button to add additional Pharos controllers 45 45 1. Navigate to the "Layout" page by clicking the pencil and ruler icon on the left 46 +1*. Overview of completed layout: 47 +1*. [[image:lyout-2_text.png]] 46 46 1. At the top left, click "Manage..." to edit the layout name and dimensions, modify grid settings, and upload a background image if desired 47 47 1. Locate the desired fixture in the Fixture Profile List on the right side of the Layout page 48 48 1*. Most fixtures can be controlled correctly using the generic single-channel, RGB, warm/cool, intensity/CCT, HSIC, etc. profiles ... ... @@ -65,12 +65,23 @@ 65 65 1*. Fixtures can be added to an existing group by selecting and then dragging them to a group in the Fixture List 66 66 1*. **Note:** dragging a fixture from one group into another will not remove it from the first group, only add it to the second group. Be careful not to accidentally assign fixtures to more groups than intended. 67 67 1. Once all fixtures have been laid out and grouped, navigate to the "Patch" page 70 +1*. Overview of a completed patch: 71 +1*. [[image:patch-2_text.png]] 72 +1. All fixtures and fixture groups in the project will appear in a hierarchical tree view on the left 73 +1*. All fixtures are present, regardless of grouping or which layout they appear on 74 +1**. Fixtures will appear multiple times: once in the "All Fixtures" section, and then again in any groups that they are assigned to 75 +1**. Patched fixtures have blue text, even if they are not patched to the currently visible universe 76 +1**. Unpatched fixtures have black text 77 +1**. The currently selected fixture has red text regardless of whether it is patched or not 78 +1*. Current patching is viewed on the screen to the right 79 +1**. By default, all universes on all controllers are shown 80 +1**. Displayed universes can be narrowed down by selecting controllers and outputs from the list of controllers 81 +1**. The currently selected fixture is highlighted in red in the fixture list and in blue if it is patched to the currently visible universe 68 68 1. Patch fixtures by dragging them from the fixture list onto the DMX universe 69 -1*. If there are multiple controllers on the job, make sure that the correct controller is selected 83 +1*. If there are multiple controllers on the job, make sure that the correct controller and universe is selected and displayed on the right 70 70 1*. For controllers with multiple universes, ensure that the fixtures are patched to the correct universe 71 71 1*. Fixtures can be patched to multiple addresses, but it is not possible to patch multiple fixtures to the same address 72 72 1*. Fixtures can be unpatched by right clicking them in the universe 73 -1*. Patching and re-patching is covered in further detail in the [[Fixture Addressing and Identification section>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Pharos Configuration.WebHome||anchor="HFixtureAddressingandIdentification"]] below. 74 74 1. If desired, navigate to the "Timeline" page and create timelines 75 75 76 76 Discovering Pharos LPC controllers and uploading a project are covered in detail in the [[Pharos Configuration section>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Program Configuration.Pharos Configuration.WebHome||anchor="HPharosConfiguration"]] below. ... ... @@ -137,6 +137,8 @@ 137 137 138 138 In order to control DMX fixtures on a Pharos controller with ShowRunner™, it is necessary to make sure that the ShowRunner™ configuration has the correct settings for the Pharos controller. Under the "LightingControllers" section of the ShowRunner™ configuration, locate the entry for the Pharos controller. Under the "Properties" section, verify that the "IpAddressOrHostname" matches the IP address or hostname of the Pharos controller. The "ApiPort" only needs to be changed if the HTTP port for the Pharos controller's web server has been changed from the default 80. Once the Properties for all Pharos controllers have been updated, load the configuration to the processor. 139 139 153 +== Define Pharos Loads in ShowRunner™ == 154 + 140 140 Control Pharos groups with ShowRunner™, it is necessary to define them as loads in the ShowRunner™ configuration. To do this using the XPanel UI, navigate to the Settings > Load Configuration page and then select the Pharos controller from the list of controllers on the left. Once the controller is selected, press the "Configure Loads" button: 141 141 142 142 * Currently defined loads are shown in the list on the left ... ... @@ -161,8 +161,10 @@ 161 161 ** If controlling the RGB and White channels of an RGBW fixture separately, then you must define an RGB type load associated with the RGB fixture group in Pharos and then a Single Channel type load associated with the White fixture group in Pharos 162 162 ** The Area Assignment dictates what area the load will be associated with 163 163 164 -S howRunner™isalso capableof triggeringTimelines in thePharosproject.This can beconfigured usingthe XPanel UI:179 +== Scene Mapping (Trigger Pharos Timelines) == 165 165 181 +ShowRunner™ is also capable of triggering Timelines in the Pharos project by mapping Pharos Timelines to ShowRunner™ Scenes. This can be configured using the XPanel UI: 182 + 166 166 1. Navigate to Settings > Load Hardware 167 167 1. Select the Pharos controller from the list of load controllers on the left 168 168 1. Press "Configure Scene Tracking" ... ... @@ -190,9 +190,9 @@ 190 190 191 191 == Re-Patching Fixtures == 192 192 193 -Since ShowRunner™ uses fixture groups to send commands to DMX fixtures on the Pharos LPC, the specific fixture address esdo not matter as long as theyare addressed according to the Pharos project. This means that if fixturesare-patched to differentaddressesin thePharosprojectbutkept inhesamefixture groups,thenno changes to the ShowRunner™ configurationare necessary.210 +Since ShowRunner™ uses fixture groups to send commands to DMX fixtures on the Pharos LPC, the specific fixture universe and address does not matter as long as fixtures have been addressed according to the Pharos project. This means that if fixtures were installed and connected to a different universe than originally anticipated, it is relatively straightforward to re-patch fixtures to different addresses on different universes while maintaining their groups in the Pharos project without requiring changes to the ShowRunner™ configuration. 194 194 195 -In order to re-patch fixtures: 212 +In order to re-patch fixtures in the Pharos project: 196 196 197 197 1. Open the project in Designer 2 and navigate to the "Patch" page 198 198 1*. All fixtures and fixture groups in the project will appear in a hierarchical tree view on the left ... ... @@ -205,7 +205,6 @@ 205 205 1**. By default, all universes on all controllers are shown 206 206 1**. Displayed universes can be narrowed down by selecting controllers and outputs from the list of controllers 207 207 1**. The currently selected fixture is highlighted in red in the fixture list and in blue if it is patched to the currently visible universe 208 -1*. [[image:patch-2_text.png]] 209 209 1. There are two options to patch or re-patch fixtures 210 210 1*. Drag the fixture from the list of fixtures on the left and onto the universe on the right 211 211 1*. Select a previously patched fixture from the universe on the right and move it to a new address, or right-click to un-patch entirely ... ... @@ -224,11 +224,20 @@ 224 224 225 225 1. Ensure that the controller in the project you wish to address fixtures for has been assigned a live (currently online) controller and that the project has been uploaded to the live controller 226 226 1. Open the project in Designer 2 and navigate to the "Patch" page 227 -1. Select the controller that you wish to address fixtures for228 -1. Press the "Discover" button that corresponds to the output that you want to address fixtures for243 +1. Select the controller that you wish to address devices for 244 +1. Press the "Discover" button that corresponds to the output that you want to address devices for 229 229 1*. Single-universe LPCs have separate "Discover" buttons corresponding to each of the two DMX outputs 230 230 1*. Multi-universe LPCs and EDNs typically have a single "Discover" button for each universe, as there is a 1-to-1 relationship between the output and the universe 231 -1. 247 +1. A window will appear and list all discovered devices, along with a unique device ID, manufacturer/model information, personality (control mode), footprint (number of required addresses), and their current start address 248 +1*. Due to manufacturer compatibility issues, some RDM-capable devices may not appear online, and available information (such as personality) may be incomplete for those devices that are online 249 +1*. Non-driver devices (such as splitters) will appear in the list, but it will not be possible to change their start address 250 +1*. In cases where RDM capable devices do not appear online, they must be addressed manually as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]] 251 +1. Click the "Identify" button and then select the device from the list of available devices in order to identify a specific RDM device 252 +1*. The device should identify itself by flashing any attached loads (if a driver), or by flashing indicator LEDs (if it is another type of device, such as a splitter) 253 +1. To change a device's start address, double-click its start address and type the new start address 254 +1. Once all devices have been identified and re-addressed, click the "Discover" button to refresh the list and verify that no new devices appear online 255 +1. Repeat steps 3 through 8 for all controllers 256 +1. If discovering on all outputs of all controllers does not reveal all the expected drivers, then it may be necessary to manually address drivers as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]] and move on to troubleshooting the DMX installation 232 232 233 233 == Address Verification == 234 234
- lyout-2_text.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +177.3 KB - Content