Changes for page Pharos Configuration
Last modified by Alexander Mott on 2024/02/26 15:10
From version 27.1
edited by Alexander Mott
on 2023/05/16 20:17
on 2023/05/16 20:17
Change comment:
Uploaded new attachment "patch-2_text.png", version {1}
To version 29.1
edited by Alexander Mott
on 2023/05/16 20:32
on 2023/05/16 20:32
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -190,9 +190,9 @@ 190 190 191 191 == Re-Patching Fixtures == 192 192 193 -Since ShowRunner™ uses fixture groups to send commands to DMX fixtures on the Pharos LPC, the specific fixture address esdo not matter as long as theyare addressed according to the Pharos project. This means that if fixturesare-patched to differentaddressesin thePharosprojectbutkept inhesamefixture groups,thenno changes to the ShowRunner™ configurationare necessary.193 +Since ShowRunner™ uses fixture groups to send commands to DMX fixtures on the Pharos LPC, the specific fixture universe and address does not matter as long as fixtures have been addressed according to the Pharos project. This means that if fixtures were installed and connected to a different universe than originally anticipated, it is relatively straightforward to re-patch fixtures to different addresses on different universes while maintaining their groups in the Pharos project without requiring changes to the ShowRunner™ configuration. 194 194 195 -In order to re-patch fixtures: 195 +In order to re-patch fixtures in the Pharos project: 196 196 197 197 1. Open the project in Designer 2 and navigate to the "Patch" page 198 198 1*. All fixtures and fixture groups in the project will appear in a hierarchical tree view on the left ... ... @@ -228,6 +228,9 @@ 228 228 1. Press the "Discover" button that corresponds to the output that you want to address fixtures for 229 229 1*. Single-universe LPCs have separate "Discover" buttons corresponding to each of the two DMX outputs 230 230 1*. Multi-universe LPCs and EDNs typically have a single "Discover" button for each universe, as there is a 1-to-1 relationship between the output and the universe 231 +1. A window will appear and list all discovered fixtures, along with a unique device ID, manufacturer/model information, personality (control mode), footprint (number of required addresses), and their current start address 232 +1*. Due to manufacturer compatibility issues, some RDM-capable fixtures may not appear online, and available information (such as personality) may be incomplete for those fixtures that are online 233 +1*. In cases where RDM capable fixtures do not appear online, they must be addressed manually as described on our [[DMX Fixture Addressing page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.DMX Fixture Addressing.WebHome||anchor="HAddressingDrivers"]] 231 231 1. 232 232 233 233 == Address Verification ==