5 5  ShowRunner™ can control DMX fixtures through several different methods, including Pharos DMX controllers. The most common Pharos controllers sold through Crestron are the Pharos LPC-1 (DIN-DMX-1UNIVERSE) and the Pharos LPC-2 (DIN-DMX-2UNIVERSE). These LPC controllers appear physically identical, but the LPC-1 shares a single universe across both DMX outputs while the LPC-2 has a separate universe for each output. ShowRunner™ uses the Pharos Controller API to send commands over Ethernet to the Pharos Controller, which then sends DMX commands to the fixtures.
6 6  
7 -This article covers the basics of Pharos Designer 2 for the purposes of integrating with ShowRunnerCLC™ installations. Further information can be found from the official[[ Pharos Designer 2 documentation>>https://dl.pharoscontrols.com/software_help/designer2/Default.htm]].
8 -
9 9  = Pharos Projects =
10 10  
11 11  ShowRunner™ integrates with Pharos LPC DMX controllers using the Pharos API. The ShowRunner™ configuration and the Pharos project loaded to the Pharos LPC need to be in coordination with each other in order for ShowRunner™ to control the DMX loads as expected. It is therefore sometimes necessary to either create or edit a Pharos project in order to determine how the DMX loads need to be defined in the ShowRunner™ configuration.
... ... @@ -117,9 +117,8 @@
117 117  1. In the Properties menu on the right, click the Serial Number dropdown menu and select the SN corresponding to the controller
118 118  1*. [[image:network-project-assign_text_crop.png]]
119 119  1*. If you do not see the corresponding serial number, click the "Find..." button to open the search menu
120 -1**. [[image:network-project-find_text_crop.png||height="356" width="826"]]
118 +1**.
121 121  1*. If you are connecting to the controller over a routed network, put the controller's IP address into this field and press the "Add" button
122 -1**. [[image:network-project-found_text_crop.png||height="631" width="1261"]]
123 123  1*. If you are connecting to a controller on a Control Subnet from the LAN side of the processor, put the processor's LAN IP address followed by a colon and the external port number that corresponds to internal port 38008 of the controller. See our [[FAQ>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] for information
124 124  1. If there are multiple controllers in the project, repeat step 6 for all controllers
125 125  1. Once all controllers defined in the project have been assigned a serial number, press the "Upload" button
network-project-assign_text_crop.png
Size
... ... @@ -1,1 +1,1 @@
1 -76.1 KB
1 +82.6 KB
Content
network-project-find_text_crop.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,1 +1,0 @@
1 -28.6 KB
Content
network-project-found_text_crop.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,1 +1,0 @@
1 -97.6 KB
Content