Changes for page Pharos Configuration
Last modified by Alexander Mott on 2024/02/26 15:10
From version 17.2
edited by Alexander Mott
on 2023/05/16 17:34
on 2023/05/16 17:34
Change comment:
There is no comment for this version
To version 14.1
edited by Alexander Mott
on 2023/05/16 14:28
on 2023/05/16 14:28
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,8 +4,6 @@ 4 4 5 5 ShowRunner™ can control DMX fixtures through several different methods, including Pharos DMX controllers. The most common Pharos controllers sold through Crestron are the Pharos LPC-1 (DIN-DMX-1UNIVERSE) and the Pharos LPC-2 (DIN-DMX-2UNIVERSE). These LPC controllers appear physically identical, but the LPC-1 shares a single universe across both DMX outputs while the LPC-2 has a separate universe for each output. ShowRunner™ uses the Pharos Controller API to send commands over Ethernet to the Pharos Controller, which then sends DMX commands to the fixtures. 6 6 7 -This article covers the basics of Pharos Designer 2 for the purposes of integrating with ShowRunnerCLC™ installations. Further information can be found from the official[[ Pharos Designer 2 documentation>>https://dl.pharoscontrols.com/software_help/designer2/Default.htm]]. 8 - 9 9 = Pharos Projects = 10 10 11 11 ShowRunner™ integrates with Pharos LPC DMX controllers using the Pharos API. The ShowRunner™ configuration and the Pharos project loaded to the Pharos LPC need to be in coordination with each other in order for ShowRunner™ to control the DMX loads as expected. It is therefore sometimes necessary to either create or edit a Pharos project in order to determine how the DMX loads need to be defined in the ShowRunner™ configuration. ... ... @@ -116,9 +116,8 @@ 116 116 1. Select a controller that is defined in the project 117 117 1. In the Properties menu on the right, click the Serial Number dropdown menu and select the SN corresponding to the controller 118 118 1*. [[image:network-project-assign_text_crop.png]] 119 -1*. If you do not see the corresponding serial number, click the "Find..." button to open the search menu 120 -1**. 121 -1*. If you are connecting to the controller over a routed network, put the controller's IP address into this field and press the "Add" button 117 +1*. If you do not see the corresponding serial number, click the "Find..." button 118 +1*. If you are connecting to the controller over a routed network, put the controller's IP address into this field 122 122 1*. If you are connecting to a controller on a Control Subnet from the LAN side of the processor, put the processor's LAN IP address followed by a colon and the external port number that corresponds to internal port 38008 of the controller. See our [[FAQ>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] for information 123 123 1. If there are multiple controllers in the project, repeat step 6 for all controllers 124 124 1. Once all controllers defined in the project have been assigned a serial number, press the "Upload" button
- network-project-assign_text_crop.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 76.1KB1 +82.6 KB - Content
- network-project-usb_text_crop.png
-
- Size
-
... ... @@ -1,1 +1,1 @@ 1 - 47.5KB1 +83.9 KB - Content