... ... @@ -29,8 +29,10 @@
29 29  ** For example, if Pharos receives an RGB command for a group containing RGB, HSI, and HSIC fixtures, it will do its best to make sure that the output color is consistent across all the different fixture types
30 30  ** Certain manufacturer-specific fixture Profiles exist in order to help the Pharos controller achieve a consistent output across multiple different fixture types
31 31  * To control the RGB and white channels of an RGBW fixture separately in ShowRunner™, it is necessary to define separate RGB and White fixtures in the Pharos project 
32 -** Add a generic RGB fixture profile to the layout
33 -** Add a generic White fixture to the layout
32 +** Add both a generic RGB fixture and a generic White fixture to the layout
33 +** Assign each fixture to a different group
34 +** Patch the RGB fixture
35 +** Patch the White fixture immediately following the RGB fixture (e.g., if the RGB is at address 1, patch the White fixture to address 4)
34 34  * Individual Fixtures can belong to multiple Fixture Groups, allowing ShowRunner™ to send different types of command (e.g. RGB vs CCT) to the same fixture 
35 35  ** Useful for certain situations, such as HSIC fixtures that need to be controlled as color-changing (RGB) in some situations but dynamic white (intensity/CCT) in others
36 36  ** In this scenario, one group would be defined in ShowRunner™ as an RGB load and one group would be defined as a Dynamic White load
... ... @@ -117,6 +117,7 @@
117 117  
118 118  * All currently defined loads are shown on the left
119 119  ** The "Group: #" of the load must match the group number as defined in the Pharos project
122 +** It is not possible to change the group of an existing load from the XPanel UI. Instead, either pull the config and edit the "LoadBaseIndex" property of the load
120 120  * To add a new load to the controller, press "Add New Load" below the list of loads
121 121  ** The "Load Index/Channel" must match the group number as defined in the Pharos project
122 122  *** Since ShowRunner™ uses group-level commands and fixtures in a group aren't necessarily on the same DMX universe, the "Universe ID" is grayed out and cannot be modified
... ... @@ -133,8 +133,8 @@
133 133  *** "RGB" loads are interpreted by the Pharos as an intensity + specific red, green, and blue values
134 134  **** Fixture profiles with a dedicated channel for intensity (IRGB, HSI, HSIC, etc.) will use the load level sent by ShowRunner™ for intensity and then mix the other channels to match the RGB values
135 135  **** Fixture profiles without a dedicated intensity channel (RGB, RGBW, etc.) will mix the intensities for each color to attempt to match the color and overall intensity sent by ShowRunner™
136 -** To control the white channel of RGBW fixtures separately from the RGB channels:
137 -*** In the Pharos project, create an
139 +** If controlling the RGB and White channels of an RGBW fixture separately, then you must define an RGB type load associated with the RGB fixture group in Pharos and then a Single Channel type load associated with the White fixture group in Pharos
140 +** The Area Assignment dictates what area the load will be associated with
138 138  
139 139  
140 140  note no feeback