Changes for page Pharos Configuration
Last modified by Alexander Mott on 2024/02/26 15:10
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -115,12 +115,9 @@ 115 115 116 116 * All currently defined loads are shown on the left 117 117 ** The "Group: #" of the load must match the group number as defined in the Pharos project 118 -* To add a new load to the controller, press "Add New Load" below the list of loads118 +* To add a new load to ShowRunner™, press "Add New Load" below the list of loads 119 119 ** The "Load Index/Channel" must match the group number as defined in the Pharos project 120 120 *** Since ShowRunner™ uses group-level commands and fixtures in a group aren't necessarily on the same DMX universe, the "Universe ID" is grayed out and cannot be modified 121 -*** It is not possible to assign multiple Pharos groups to the same load, and it is not possible to assign multiple loads to the same group 122 -**** To have a single load in ShowRunner™ control multiple Pharos groups, create a new group in the Pharos project that contains the other groups and then associate the ShowRunner™ load with the super-group 123 -**** To have multiple ShowRunner™ loads control the same set of fixtures, create multiple groups in the Pharos project and assign the same fixtures to all groups (this is useful e.g. to allow ShowRunner™ to control an HSIC fixture using either RGB or dynamic white without needing to change the Load Type) 124 124 ** The "Load Type" does not need to strictly match the fixture type as defined in the Pharos project, as the Pharos controller will do its own processing to mix the DMX output to achieve the desired color 125 125 *** "Single Channel" loads are interpreted by the Pharos as intensity only 126 126 **** Fixture profiles with a dedicated channel for intensity (IRGB, HSI, HSIC, ICHS, etc.) will only adjust the intensity channel, leaving the color and color temperature unchanged ... ... @@ -131,7 +131,9 @@ 131 131 *** "RGB" loads are interpreted by the Pharos as an intensity + specific red, green, and blue values 132 132 **** Fixture profiles with a dedicated channel for intensity (IRGB, HSI, HSIC, etc.) will use the load level sent by ShowRunner™ for intensity and then mix the other channels to match the RGB values 133 133 **** Fixture profiles without a dedicated intensity channel (RGB, RGBW, etc.) will mix the intensities for each color to attempt to match the color and overall intensity sent by ShowRunner™ 134 -** To control the white channel of RGBW fixtures separately from the RGB channels, the white 131 +* It is not possible to assign multiple Pharos groups to the same load, and it is not possible to assign multiple loads to the same group 132 +** To have a single load in ShowRunner™ control multiple Pharos groups, it is necessary to create a group in the Pharos project that contains the other groups and then associate the ShowRunner™ load with the super-group 133 +** To have 135 135 136 136 137 137 note no feeback