... ... @@ -28,7 +28,11 @@
28 28  * The Pharos controller does any necessary processing to adapt these commands for the fixtures
29 29  ** For example, if Pharos receives an RGB command for a group containing RGB, HSI, and HSIC fixtures, it will do its best to make sure that the output color is consistent across all the different fixture types
30 30  ** Certain manufacturer-specific fixture Profiles exist in order to help the Pharos controller achieve a consistent output across multiple different fixture types
31 -* If it is desired to control the white channel separately from the RGB channels of an RGBW fixture, then it must be defined in the Pharos project as two separate RGB and W fixtures that are in different groups
31 +* To control the RGB and white channels of an RGBW fixture separately in ShowRunner™, it is necessary to define separate RGB and White fixtures in the Pharos project 
32 +** Add both a generic RGB fixture and a generic White fixture to the layout
33 +** Assign each fixture to a different group
34 +** Patch the RGB fixture
35 +** Patch the White fixture immediately following the RGB fixture (e.g., if the RGB is at address 1, patch the White fixture to address 4)
32 32  * Individual Fixtures can belong to multiple Fixture Groups, allowing ShowRunner™ to send different types of command (e.g. RGB vs CCT) to the same fixture 
33 33  ** Useful for certain situations, such as HSIC fixtures that need to be controlled as color-changing (RGB) in some situations but dynamic white (intensity/CCT) in others
34 34  ** In this scenario, one group would be defined in ShowRunner™ as an RGB load and one group would be defined as a Dynamic White load
... ... @@ -114,15 +114,26 @@
114 114  To add Pharos loads to ShowRunner™, launch the XPanel and navigate to the Settings > Load Configuration page and then select the Pharos controller from the list of controllers on the left. Once the controller is selected, press the "Configure Loads" button:
115 115  
116 116  * All currently defined loads are shown on the left
117 -** The "Group: #" of the load must match the group number as defined in the Pharos project
121 +** The "Group: #" of the load must match the group number as defined in the Pharos project
122 +** It is not possible to change the group of an existing load from the XPanel UI. Instead, either pull the config and edit the "LoadBaseIndex" property of the load
123 +* To add a new load to the controller, press "Add New Load" below the list of loads
124 +** The "Load Index/Channel" must match the group number as defined in the Pharos project
125 +*** Since ShowRunner™ uses group-level commands and fixtures in a group aren't necessarily on the same DMX universe, the "Universe ID" is grayed out and cannot be modified
126 +*** It is not possible to assign multiple Pharos groups to the same load, and it is not possible to assign multiple loads to the same group
127 +**** To have a single load in ShowRunner™ control multiple Pharos groups, create a new group in the Pharos project that contains the other groups and then associate the ShowRunner™ load with the super-group
128 +**** To have multiple ShowRunner™ loads control the same set of fixtures, create multiple groups in the Pharos project and assign the same fixtures to all groups (this is useful e.g. to allow ShowRunner™ to control an HSIC fixture using either RGB or dynamic white without needing to change the Load Type)
118 118  ** The "Load Type" does not need to strictly match the fixture type as defined in the Pharos project, as the Pharos controller will do its own processing to mix the DMX output to achieve the desired color
119 -*** "Single Channel" loads are interpreted by the Pharos as "intensity only"
120 -*** "Dynamic White" loads are interpreted by the Pharos as "intensity + color temperature"
121 -**** Pharos will translate the input received from ShowRunner™ HSIC, Intensity/CCT, Warm/Cool, etc. fixture profiles in Pharos will
122 -*** "RGB" loads are interpreted by the Pharos as specific red, green, and blue values
123 -* It is not possible to assign multiple Pharos groups to the same load, and it is not possible to assign multiple loads to the same group
124 -** To have a single load in ShowRunner™ control multiple Pharos groups, it is necessary to create a group in the Pharos project that contains the other groups and then associate the ShowRunner™ load with the super-group
125 -** To have
130 +*** "Single Channel" loads are interpreted by the Pharos as intensity only 
131 +**** Fixture profiles with a dedicated channel for intensity (IRGB, HSI, HSIC, ICHS, etc.) will only adjust the intensity channel, leaving the color and color temperature unchanged
132 +**** Fixture profiles without a dedicated intensity channel (RGB, RGBA, RGBW, etc.) will set all channels to the same intensity value sent by ShowRunner™
133 +*** "Dynamic White" loads are interpreted by the Pharos as an intensity and a color temperature
134 +**** Fixture profiles with dedicated intensity and color temperature (HSIC, ICHS, I/CCT, etc.) will use the values sent by ShowRunner™
135 +**** Pharos will attempt to mix the DMX output for fixture profiles without dedicated intensity and color temperature channels (warm/cool, RGBW, etc.) in order to match the values sent by ShowRunner™
136 +*** "RGB" loads are interpreted by the Pharos as an intensity + specific red, green, and blue values
137 +**** Fixture profiles with a dedicated channel for intensity (IRGB, HSI, HSIC, etc.) will use the load level sent by ShowRunner™ for intensity and then mix the other channels to match the RGB values
138 +**** Fixture profiles without a dedicated intensity channel (RGB, RGBW, etc.) will mix the intensities for each color to attempt to match the color and overall intensity sent by ShowRunner™
139 +** If controlling the RGB and White channels of an RGBW fixture separately, then you must define an RGB type load associated with the RGB fixture group in Pharos and then a Single Channel type load associated with the White fixture group in Pharos
140 +** The Area Assignment dictates what area the load will be associated with
126 126  
127 127  
128 128  note no feeback