Changes for page Pharos Configuration

Last modified by Alexander Mott on 2024/02/26 15:10

From version 1.37
edited by Alexander Mott
on 2023/05/05 20:49
Change comment: (Autosaved)
To version 1.38
edited by Alexander Mott
on 2023/05/05 20:54
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -116,10 +116,12 @@
116 116  * All currently defined loads are shown on the left
117 117  ** The "Group: #" of the load must match the group number as defined in the Pharos project
118 118  ** The "Load Type" does not need to strictly match the fixture type as defined in the Pharos project, as the Pharos controller will do its own processing to mix the DMX output to achieve the desired color
119 -*** "Single Channel" loads are interpreted by the Pharos as "intensity only"
120 -*** "Dynamic White" loads are interpreted by the Pharos as "intensity + color temperature"
121 -**** Pharos will translate the input received from ShowRunner™ HSIC, Intensity/CCT, Warm/Cool, etc. fixture profiles in Pharos will
122 -*** "RGB" loads are interpreted by the Pharos as specific red, green, and blue values
119 +*** "Single Channel" loads are interpreted by the Pharos as intensity only 
120 +**** Fixture profiles with a dedicated channel for intensity (IRGB, HSI, HSIC, ICHS, etc.) will only adjust the intensity, leaving the color and color temperature unchanged
121 +**** Fixture profiles without a dedicated intensity channel (RGB, RGBA, RGBW, etc.) will set all channels to the same intensity
122 +*** "Dynamic White" loads are interpreted by the Pharos as an intensity and a color temperature
123 +****
124 +*** "RGB" loads are interpreted by the Pharos as a specific color value
123 123  * It is not possible to assign multiple Pharos groups to the same load, and it is not possible to assign multiple loads to the same group
124 124  ** To have a single load in ShowRunner™ control multiple Pharos groups, it is necessary to create a group in the Pharos project that contains the other groups and then associate the ShowRunner™ load with the super-group
125 125  ** To have