Changes for page Pharos Configuration
Last modified by Alexander Mott on 2024/02/26 15:10
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -48,7 +48,7 @@ 48 48 1. Locate the desired fixture in the Fixture Profile List on the right side of the Layout page 49 49 1*. Most fixtures can be controlled correctly using the generic single-channel, RGB, warm/cool, intensity/CCT, HSIC, etc. profiles 50 50 1*. Additional generic and manufacturer-specific profiles can be downloaded by clicking the cloud icon on the right, above the fixture profile list 51 -1. Add fixtures to the layout by dragging them from the FixtureProfileList51 +1. Add fixtures to the layout by dragging them from the fixture profile list 52 52 1*. Every fixture that is added to the layout represents a unique set of DMX addresses 53 53 1*. The fixture number is different than the fixture address, and is automatically incremented by Pharos Designer 2 54 54 1*. Fixture properties such as name, shape, and size can be edited using the menu on the right ... ... @@ -55,7 +55,7 @@ 55 55 1*. Right-clicking a fixture on the layout will allow you to either "Duplicate" or create a "New Instance" of a fixture 56 56 1**. Duplicating a fixture creates a new fixture with the same profile and properties but that will occupy different DMX addresses 57 57 1**. Creating a New Instance will create a new representation of the fixture without actually creating a new fixture; this allows you to have multiple fixtures represented on the layout that share the same DMX address 58 -1. Create Fixture Groups by clicking the folder icon above the FixtureListon the left or by right clicking an empty area in theFixtureList58 +1. Create Fixture Groups by clicking the folder icon above the list of fixtures on the left or by right clicking an empty area in the fixture list 59 59 1*. Fixture Groups will correspond to individual loads in ShowRunner™ 60 60 1*. When a new Fixture Group is created, all currently selected fixtures are automatically added to the group 61 61 1**. Clicking a fixture on the layout or in the fixture list will select just that fixture ... ... @@ -62,51 +62,13 @@ 62 62 1**. Ctrl-clicking a fixture will add or remove it from the current selection 63 63 1**. Ctrl-dragging on the layout will add multiple fixtures to the current selection 64 64 1**. Shift-dragging on the layout will select just the highlighted fixtures 65 -1*. Fixtures can be removed from a group by right clicking them under the group in the FixtureList66 -1*. Fixtures can be added to an existing group by selecting and then dragging them to agroup in theFixtureList65 +1*. Fixtures can be removed from a group by right clicking them under the group in the fixture list 66 +1*. Fixtures can be added to an existing group by selecting them and then dragging them to the group in the fixture list 67 67 1. Once all fixtures have been laid out and grouped, navigate to the "Patch" page 68 -1. Patch fixtures by dragging them from the fixture list onto the DMX universe 69 -1*. If there are multiple controllers on the job, make sure that the correct controller is selected 70 -1*. For controllers with multiple universes, ensure that the fixtures are patched to the correct universe 71 -1*. Fixtures can be patched to multiple addresses, but it is not possible to patch multiple fixtures to the same address 72 -1*. Fixtures can be unpatched by right clicking them in the universe 73 -1. If desired, navigate to the "Timeline" page and create timelines 68 +1. 74 74 75 75 = Device Configuration = 76 76 77 -ShowRunner™ must be able to communicate with the Pharos controller via Ethernet in order for control to work. Pharos controllers ship in DHCP mode by default, but they will sometimes fail to get an address if the controller is powered up before the DHCP server is running. If this happens, or if there is no DHCP server on the network, then it is necessary to configure the controller via USB: 78 - 79 -1. Open Pharos Designer 2 or an existing Pharos project 80 -1. Connect to the Pharos controller using the USB-B port on the front of the controller 81 -1. Navigate to the "Network" page 82 -1. Select the Pharos controller from the list 83 -1*. If a Pharos project is open, controllers defined in the project will be displayed above the list of online controllers 84 -1*. If there are multiple online controllers, use the "Beacon" function to flash all the LEDs on the front of the controller and verify the correct one is selected 85 -1. If the Pharos Designer 2 version is different than the firmware on the Pharos controller, then it is necessary to either update the controller by pressing the "Reload Firmware" button, or downgrade Pharos Designer 2 by downloading the appropriate version from Pharos Controls' website 86 -1. Press the "Configure" button to open the network configuration menu 87 -1. Set DHCP mode to Static and configure the IP address, IP mask, default gateway, and DNS servers as required for your network 88 - 89 -Once the Pharos controller is online, it is necessary to load the Pharos project to the controller: 90 - 91 -1. Open the Pharos project in Pharos Designer 2 92 -1. Connect to the network that the Pharos controller is on, or connect to the controller directly via USB 93 -1. Navigate to the "Network" page in Pharos Designer 2 94 -1. Verify that all online controllers have firmware that matches the version of Pharos Designer 2 you are running, and update them if necessary 95 -1*. Online controllers are displayed below the list of controllers that are defined in the project 96 -1*. If you do not see the controller online and you are hard-wired to the same network as the controller, verify that the controller has the correct IP settings 97 -1*. If the controller is on a Control Subnet and you are connecting via the LAN, [[verify that port forwarding has been configured>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] and proceed to the next step 98 -1*. If you do not see the controller online, but you are connecting to it over a routed network, proceed to the next step 99 -1. Select a controller that is defined in the project 100 -1. In the Properties menu on the right, click the Serial Number dropdown menu and select the SN corresponding to the controller 101 -1*. If you do not see the corresponding serial number, click the "Find..." button 102 -1*. If you are connecting to the controller over a routed network, put the controller's IP address into this field 103 -1*. If you are connecting to a controller on a Control Subnet from the LAN side of the processor, put the processor's LAN IP address followed by a colon and the external port number that corresponds to internal port 38008 of the controller. See our [[FAQ>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] for information 104 -1. If there are multiple controllers in the project, repeat step 6 for all controllers 105 -1. Once all controllers defined in the project have been assigned a serial number, press the "Upload" button 106 -1. Upload the project to individual controllers, or press the "Upload All" button to upload the project to all online controllers 107 - 108 -Pharos projects can also be loaded to controllers using the web interface, but in these cases it is still necessary to assign the Serial Number of the controller to the controller that is defined in the Pharos project. Additionally, the Pharos project must be exported for upload. See our [[FAQ>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20load%20my%20Pharos%20project%20using%20the%20Pharos%20web%20interface]] for details. 109 - 110 110 = ShowRunner™ Configuration = 111 111 112 112 no feedback from dmx