Changes for page Pharos Configuration
Last modified by Alexander Mott on 2024/02/26 15:10
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -93,17 +93,10 @@ 93 93 1. Navigate to the "Network" page in Pharos Designer 2 94 94 1. Verify that all online controllers have firmware that matches the version of Pharos Designer 2 you are running, and update them if necessary 95 95 1*. Online controllers are displayed below the list of controllers that are defined in the project 96 -1*. If you do not see the controller online and you are hard-wired to the same network as the controller, verify that the controller has the correct IP settings 97 -1*. If the controller is on a Control Subnet and you are connecting via the LAN, [[verify that port forwarding has been configured>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] and proceed to the next step 98 -1*. If you do not see the controller online, but you are connecting to it over a routed network, proceed to the next step 99 -1. Select a controller that is defined in the project 100 -1. In the Properties menu on the right, click the Serial Number dropdown menu and select the SN corresponding to the controller 101 -1*. If you do not see the corresponding serial number, click the "Find..." button 102 -1*. If you are connecting to the controller over a routed network, put the controller's IP address into this field 103 -1*. If you are connecting to a controller on a Control Subnet from the LAN side of the processor, put the processor's LAN IP address followed by a colon and the external port number that corresponds to internal port 38008 of the controller. See our [[FAQ>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] for information 104 -1. If there are multiple controllers in the project, repeat step 6 for all controllers 105 -1. Once all controllers defined in the project have been assigned a serial number, press the "Upload" button 96 +1. Select the controller in the project 106 106 98 +If connecting to a Pharos controller located on the Control Subnet of a Crestron processor from the LAN side of the processor, then it is necessary to configure port forwarding on the processor before the project 99 + 107 107 = ShowRunner™ Configuration = 108 108 109 109 no feedback from dmx