... ... @@ -97,14 +97,21 @@
97 97  1*. If the controller is on a Control Subnet and you are connecting via the LAN, [[verify that port forwarding has been configured>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] and proceed to the next step
98 98  1*. If you do not see the controller online, but you are connecting to it over a routed network, proceed to the next step
99 99  1. Select a controller that is defined in the project
100 -1. In the Properties menu on the right, assign the Serial Number to the controller
101 -1*. If
100 +1. In the Properties menu on the right, click the Serial Number dropdown menu and select the SN corresponding to the controller
101 +1*. If you do not see the corresponding serial number, click the "Find..." button
102 +1*. If you are connecting to the controller over a routed network, put the controller's IP address into this field
103 +1*. If you are connecting to a controller on a Control Subnet from the LAN side of the processor, put the processor's LAN IP address followed by a colon and the external port number that corresponds to internal port 38008 of the controller. See our [[FAQ>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] for information
104 +1. If there are multiple controllers in the project, repeat step 6 for all controllers
105 +1. Once all controllers defined in the project have been assigned a serial number, press the "Upload" button
106 +1. Upload the project to individual controllers, or press the "Upload All" button to upload the project to all online controllers
102 102  
103 -If connecting to a Pharos controller located on the Control Subnet of a Crestron processor from the LAN side of the processor, then it is necessary to configure port forwarding on the processor before the project
108 +Pharos projects can also be loaded to controllers using the web interface, but in these cases it is still necessary to assign the Serial Number of the controller to the controller that is defined in the Pharos project. Additionally, the Pharos project must be exported for upload. See our [[FAQ>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20load%20my%20Pharos%20project%20using%20the%20Pharos%20web%20interface]] for details.
104 104  
105 105  = ShowRunner™ Configuration =
106 106  
107 -no feedback from dmx
112 +In order to control DMX fixtures on a Pharos controller with ShowRunner™, it is necessary to make sure that the ShowRunner™ configuration has the correct settings for the Pharos controller. Under the "LightingControllers" section of the ShowRunner™ configuration, locate the entry for the Pharos controller. Under the "Properties" section, verify that the "IpAddressOrHostname" matches the IP address or hostname of the Pharos controller. The "ApiPort" only needs to be changed if the HTTP port for the Pharos controller's web server has been changed from the default 80.
108 108  
109 -
114 +Once the Properties for all Pharos controllers have been updated, load the configuration to the processor.
115 +
116 +When creating Pharos loads in ShowRunner™, the "Load Index/Channel" of the load corresponds to the group number of a Fixture Group in the Pharos project. It is not possible to assign multiple Pharos groups to the same load, and it is not possible to assign multiple loads to the same group