Changes for page Pharos Configuration
Last modified by Alexander Mott on 2024/02/26 15:10
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -93,7 +93,12 @@ 93 93 1. Navigate to the "Network" page in Pharos Designer 2 94 94 1. Verify that all online controllers have firmware that matches the version of Pharos Designer 2 you are running, and update them if necessary 95 95 1*. Online controllers are displayed below the list of controllers that are defined in the project 96 -1. Select the controller in the project 96 +1*. If you do not see the controller online and you are hard-wired to the same network as the controller, verify that the controller has the correct IP settings 97 +1*. If the controller is on a Control Subnet and you are connecting via the LAN, [[verify that port forwarding has been configured>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] and proceed to the next step 98 +1*. If you do not see the controller online, but you are connecting to it over a routed network, proceed to the next step 99 +1. Select a controller that is defined in the project 100 +1. In the Properties menu on the right, assign the Serial Number to the controller 101 +1*. If 97 97 98 98 If connecting to a Pharos controller located on the Control Subnet of a Crestron processor from the LAN side of the processor, then it is necessary to configure port forwarding on the processor before the project 99 99