... ... @@ -93,7 +93,12 @@
93 93  1. Navigate to the "Network" page in Pharos Designer 2
94 94  1. Verify that all online controllers have firmware that matches the version of Pharos Designer 2 you are running, and update them if necessary
95 95  1*. Online controllers are displayed below the list of controllers that are defined in the project
96 -1. Select the controller in the project
96 +1*. If you do not see the controller online and you are hard-wired to the same network as the controller, verify that the controller has the correct IP settings
97 +1*. If the controller is on a Control Subnet and you are connecting via the LAN, [[verify that port forwarding has been configured>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20Pharos%20LPC%20on%20the%20Control%20Subnet]] and proceed to the next step
98 +1*. If you do not see the controller online, but you are connecting to it over a routed network, proceed to the next step
99 +1. Select a controller that is defined in the project
100 +1. In the Properties menu on the right, assign the Serial Number to the controller
101 +1*. If
97 97  
98 98  If connecting to a Pharos controller located on the Control Subnet of a Crestron processor from the LAN side of the processor, then it is necessary to configure port forwarding on the processor before the project
99 99