... ... @@ -78,9 +78,25 @@
78 78  
79 79  1. Open Pharos Designer 2 or an existing Pharos project
80 80  1. Connect to the Pharos controller using the USB-B port on the front of the controller
81 -1. Navigate to the Network tab and select the LPC
82 -1. If the Pharos Designer 2 version is different than the firmware on the Pharos controller, then it is necessary to either update the controller by pressing "Reload Firmor downgrade Pharos Designer 2
81 +1. Navigate to the "Network" page
82 +1. Select the Pharos controller from the list
83 +1*. If a Pharos project is open, controllers defined in the project will be displayed above the list of online controllers
84 +1*. If there are multiple online controllers, use the "Beacon" function to flash all the LEDs on the front of the controller and verify the correct one is selected
85 +1. If the Pharos Designer 2 version is different than the firmware on the Pharos controller, then it is necessary to either update the controller by pressing the "Reload Firmware" button, or downgrade Pharos Designer 2 by downloading the appropriate version from Pharos Controls' website
86 +1. Press the "Configure" button to open the network configuration menu
87 +1. Set DHCP mode to Static and configure the IP address, IP mask, default gateway, and DNS servers as required for your network
83 83  
89 +Once the Pharos controller is online, it is necessary to load the Pharos project to the controller:
90 +
91 +1. Open the Pharos project in Pharos Designer 2
92 +1. Connect to the network that the Pharos controller is on, or connect to the controller directly via USB
93 +1. Navigate to the "Network" page in Pharos Designer 2
94 +1. Verify that all online controllers have firmware that matches the version of Pharos Designer 2 you are running, and update them if necessary
95 +1*. Online controllers are displayed below the list of controllers that are defined in the project
96 +1. Select the controller in the project
97 +
98 +If connecting to a Pharos controller located on the Control Subnet of a Crestron processor from the LAN side of the processor, then it is necessary to configure port forwarding on the processor before the project
99 +
84 84  = ShowRunner™ Configuration =
85 85  
86 86  no feedback from dmx