... ... @@ -12,12 +12,7 @@
12 12  
13 13  When creating a Pharos project for a ShowRunner™ installation, there are several things to consider:
14 14  
15 -* Individual loads in ShowRunner™ send group-level commands to Fixture Groups in Pharos
16 -* Scene recalls in ShowRunner™ can be made to trigger Timelines in Pharos
17 -* The Pharos API limits group-level commands to single-channel (intensity), RGB, and intensity/CCT
18 -** The Pharos c
19 -* The Pharos Controller does all the processing necessary to adapt an API command to the appropriate DMX outputs
20 -** E.g., Pharos will
15 +* The Pharos API limits commands to single-channel (intensity), RGB, and intensity/CCT
21 21  * ShowRunner™ uses group-level commands, so each individual load in ShowRunner™ must have a corresponding Fixture Group in Pharos
22 22  * Fixture Groups defined as single-channel loads in ShowRunner™