Details

Page properties
Content
... ... @@ -12,7 +12,12 @@
12 12  
13 13  When creating a Pharos project for a ShowRunner™ installation, there are several things to consider:
14 14  
15 -* The Pharos API limits commands to single-channel (intensity), RGB, and intensity/CCT
15 +* Individual loads in ShowRunner™ send group-level commands to Fixture Groups in Pharos
16 +* Scene recalls in ShowRunner™ can be made to trigger Timelines in Pharos
17 +* The Pharos API limits group-level commands to single-channel (intensity), RGB, and intensity/CCT
18 +** The Pharos c
19 +* The Pharos Controller does all the processing necessary to adapt an API command to the appropriate DMX outputs
20 +** E.g., Pharos will
16 16  * ShowRunner™ uses group-level commands, so each individual load in ShowRunner™ must have a corresponding Fixture Group in Pharos
17 17  * Fixture Groups defined as single-channel loads in ShowRunner™
18 18  * For RGBW fixtures, it may be a good idea to define them as separate RGB and W fixtures so that ShowRunner™ is able to control the white channel separately from the RGB channels