Changes for page Toolbox Basics
Last modified by Alexander Mott on 2024/03/19 21:00
From version 77.2
edited by Alexander Mott
on 2023/12/18 17:14
on 2023/12/18 17:14
Change comment:
There is no comment for this version
To version 66.1
edited by Alexander Mott
on 2023/12/14 22:31
on 2023/12/14 22:31
Change comment:
Uploaded new attachment "sm1.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -234,74 +234,27 @@ 234 234 * DeviceSummary.csv: 235 235 [[image:https://wiki.chiefintegrations.com/download/SHOWRUNNER%E2%84%A2%20Setup%20Guide/SHOWRUNNER%E2%84%A2%20Installation%20Guide/SHOWRUNNER%E2%84%A2%20Installation%20and%20Network%20Setup/ZUMNET-JBOX%20Setup/WebHome/1655487132138-904.png?rev=1.1||alt="1655487132138-904.png" height="289" width="752"]] 236 236 237 -== Text Console == 238 - 239 - 240 240 (% class="box warningmessage" %) 241 241 ((( 242 242 This section is under construction: please check back at a later date for more information 243 243 ))) 244 244 242 +== Text Console == 243 + 245 245 Text Console [[image:1663622220065-810.png]] is one of the most important tools in the Crestron Toolbox. Whenever the Chief Integrations' ShowRunnerCLC™ Startup Guide mentions "sending console commands," the Text Console is the tool that is required. 246 246 247 -- help commands 248 - 249 -- sr commands 250 - 251 -- link to other pages 252 - 253 253 == File Manager == 254 254 255 255 File Manager [[image:1663622340028-319.png]] is an essential tool for transferring files to and from the processor. While the ShowRunnerCLC™ license and configuration files can be loaded through the ShowRunnerHUB™ Web UI, it is still sometimes necessary to use the File Manager tool in certain circumstances (e.g., an Ethernet connection to the device cannot be established or for transferring files that aren't supported through the Web UI, such as custom ShowRunner™ extensions). 256 256 257 -To use File Manager: 258 - 259 -* Open the File Manager tool and connect to your device 260 -** Note that not all devices have accessible storage, so File Manager tool will not always connect even if the device is online 261 -[[image:fm1.png||height="155" width="478"]] 262 -* Navigate your device's storage using either the navigation bar on the left or by double-clicking into folders on the right 263 -** Note that some older versions of Toolbox only allow navigation using the navigation bar on the left 264 -[[image:fm2.png||height="152" width="474"]] 265 -* 266 -* For normal Crestron processors (i.e. //not// VC-4 instances), ShowRunnerCLC™ files belong in the following folders: 267 -** ShowRunnerCLC™ license goes into the "NVRAM/sr/" folder 268 -** ShowRunnerCLC™ SrConfig.json configuration file goes into the "NVRAM/sr/default" folder 269 -** Note that ShowRunnerCLC™ 270 - 271 271 == Network Device Tree View == 272 272 273 -(% class="box warningmessage" %) 274 -((( 275 -This section is under construction: please check back at a later date for more information 276 -))) 252 +Network Device Tree View [[image:1663622313939-259.png]] is a useful tool for [[device addressing>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Addressing Devices from Toolbox.WebHome||anchor="HNetworkDeviceTreeView"]]. 277 277 278 -Network Device Tree View [[image:1663622313939-259.png]] is a useful tool for addressing devices and resolving certain issues with networked hardware. See our [[device addressing>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Addressing Devices from Toolbox.WebHome||anchor="HNetworkDeviceTreeView"]] page for specific instructions on how to use the Network Device Tree View for device addressing. 279 - 280 280 == Script Manager == 281 281 282 - The Script Manager [[image:1663622272369-417.png]] is whereLoad Scriptscan be opened and specific sets of commands executed. Load Scripts are .txt files that allow you to automate certain tasks by connecting to a device and executing a predetermined sequence of commands, andarea powerfultoolto savetimeon-sitewhenyou needtorunthesameor similarsetof commandson manydevices.256 +Load Scripts are .txt files that allow you to automate certain tasks by connecting to a device and executing a predetermined sequence of commands, and the Script Manager [[image:1663622272369-417.png]] is where Load Scripts can be opened and executed. 283 283 284 -To use a Load Script with the Load Script Manager: 285 - 286 -* Open the Load Script Manager in Toolbox 287 -* Right-click anywhere in the Load Script Manager, select "Load Script...", and locate your Load Script .txt file 288 -* The window will populate with all of the different command sets defined in the Load Script 289 -** Ensure that you are connected to your devices by the method required based on the connection type listed in the "Connection" column 290 -** This example script is expecting to connect to devices over Ethernet using their hostname 291 -[[image:sm1.png||height="218" width="954"]] 292 -* Select the command sets you would like to execute by ctrl+clicking or shift+clicking them and then right-click and "Start Selected" to begin executing the commands 293 -** If no commands are currently running, the "Start All" option will also be available. Note that the number of concurrent command sections may be limited by the load script, so even if "Start All" is selected there may only be e.g. 10 command sets that actually start 294 -** If commands are currently running, you can cancel them using this right-click menu as well 295 -[[image:sm2.png]] 296 -* While commands are running, their current status and progress are displayed under the various columns displayed in the Script Manager 297 -[[image:sm3.png||height="189" width="835"]] 298 -* Once a command section has executed all commands, it will display the success or failure of the commands 299 -** In this example, all of the commands failed for different reasons: 300 -** ZUMNET-JBOX-16A-LV-F2D94E commands failed due to the firmware file specified by the script not being in the correct location 301 -** The commands which failed due to an "unknown error" failed because they weren't reachable at the specified connection address due to some quirks with this specific LAN configuration 302 -** The remaining command sections were manually cancelled before they could complete 303 -[[image:sm4.png||height="205" width="904"]] 304 - 305 305 == Package Update Tool == 306 306 307 307 The Package Update Tool [[image:1663622297411-164.png]] is a very convenient way of [[performing firmware updates>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome||anchor="HPackageUpdateTool28.puf29"]] for networked devices and [[loading the ShowRunnerCLC™ program>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HProgramLoad"]] to processors.
- fm1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -10.2 KB - Content
- fm2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.4 KB - Content
- sm2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -8.3 KB - Content
- sm3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -30.5 KB - Content
- sm4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.7 KB - Content