Changes for page Toolbox Basics
Last modified by Alexander Mott on 2024/03/19 21:00
From version 68.1
edited by Alexander Mott
on 2023/12/14 22:43
on 2023/12/14 22:43
Change comment:
Uploaded new attachment "sm3.png", version {1}
To version 79.1
edited by Alexander Mott
on 2023/12/18 18:34
on 2023/12/18 18:34
Change comment:
Uploaded new attachment "fm3b.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -234,27 +234,74 @@ 234 234 * DeviceSummary.csv: 235 235 [[image:https://wiki.chiefintegrations.com/download/SHOWRUNNER%E2%84%A2%20Setup%20Guide/SHOWRUNNER%E2%84%A2%20Installation%20Guide/SHOWRUNNER%E2%84%A2%20Installation%20and%20Network%20Setup/ZUMNET-JBOX%20Setup/WebHome/1655487132138-904.png?rev=1.1||alt="1655487132138-904.png" height="289" width="752"]] 236 236 237 +== Text Console == 238 + 239 + 237 237 (% class="box warningmessage" %) 238 238 ((( 239 239 This section is under construction: please check back at a later date for more information 240 240 ))) 241 241 242 -== Text Console == 243 - 244 244 Text Console [[image:1663622220065-810.png]] is one of the most important tools in the Crestron Toolbox. Whenever the Chief Integrations' ShowRunnerCLC™ Startup Guide mentions "sending console commands," the Text Console is the tool that is required. 245 245 247 +- help commands 248 + 249 +- sr commands 250 + 251 +- link to other pages 252 + 246 246 == File Manager == 247 247 248 248 File Manager [[image:1663622340028-319.png]] is an essential tool for transferring files to and from the processor. While the ShowRunnerCLC™ license and configuration files can be loaded through the ShowRunnerHUB™ Web UI, it is still sometimes necessary to use the File Manager tool in certain circumstances (e.g., an Ethernet connection to the device cannot be established or for transferring files that aren't supported through the Web UI, such as custom ShowRunner™ extensions). 249 249 257 +To use File Manager: 258 + 259 +* Open the File Manager tool and connect to your device 260 +** Note that not all devices have accessible storage, so File Manager tool will not always connect even if the device is online 261 +[[image:fm1.png||height="155" width="478"]] 262 +* Navigate your device's storage using either the navigation bar on the left or by double-clicking into folders on the right 263 +** Note that some older versions of Toolbox only allow navigation using the navigation bar on the left 264 +[[image:fm2.png||height="152" width="474"]] 265 +* 266 +* For normal Crestron processors (i.e. //not// VC-4 instances), ShowRunnerCLC™ files belong in the following folders: 267 +** ShowRunnerCLC™ license goes into the "NVRAM/sr/" folder 268 +** ShowRunnerCLC™ SrConfig.json configuration file goes into the "NVRAM/sr/default" folder 269 +** Note that ShowRunnerCLC™ 270 + 250 250 == Network Device Tree View == 251 251 252 -Network Device Tree View [[image:1663622313939-259.png]] is a useful tool for [[device addressing>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Addressing Devices from Toolbox.WebHome||anchor="HNetworkDeviceTreeView"]]. 273 +(% class="box warningmessage" %) 274 +((( 275 +This section is under construction: please check back at a later date for more information 276 +))) 253 253 278 +Network Device Tree View [[image:1663622313939-259.png]] is a useful tool for addressing devices and resolving certain issues with networked hardware. See our [[device addressing>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Device Addressing.Addressing Devices from Toolbox.WebHome||anchor="HNetworkDeviceTreeView"]] page for specific instructions on how to use the Network Device Tree View for device addressing. 279 + 254 254 == Script Manager == 255 255 256 -Load Scripts are .txt files that allow you to automate certain tasks by connecting to a device and executing a predetermined sequence of commands, and theScriptManager[[image:1663622272369-417.png]]is whereLoadScriptscanbe opened andexecuted.282 +The Script Manager [[image:1663622272369-417.png]] is where Load Scripts can be opened and specific sets of commands executed. Load Scripts are .txt files that allow you to automate certain tasks by connecting to a device and executing a predetermined sequence of commands, and are a powerful tool to save time on-site when you need to run the same or similar set of commands on many devices. 257 257 284 +To use a Load Script with the Load Script Manager: 285 + 286 +* Open the Load Script Manager in Toolbox 287 +* Right-click anywhere in the Load Script Manager, select "Load Script...", and locate your Load Script .txt file 288 +* The window will populate with all of the different command sets defined in the Load Script 289 +** Ensure that you are connected to your devices by the method required based on the connection type listed in the "Connection" column 290 +** This example script is expecting to connect to devices over Ethernet using their hostname 291 +[[image:sm1.png||height="218" width="954"]] 292 +* Select the command sets you would like to execute by ctrl+clicking or shift+clicking them and then right-click and "Start Selected" to begin executing the commands 293 +** If no commands are currently running, the "Start All" option will also be available. Note that the number of concurrent command sections may be limited by the load script, so even if "Start All" is selected there may only be e.g. 10 command sets that actually start 294 +** If commands are currently running, you can cancel them using this right-click menu as well 295 +[[image:sm2.png]] 296 +* While commands are running, their current status and progress are displayed under the various columns displayed in the Script Manager 297 +[[image:sm3.png||height="189" width="835"]] 298 +* Once a command section has executed all commands, it will display the success or failure of the commands 299 +** In this example, all of the commands failed for different reasons: 300 +** ZUMNET-JBOX-16A-LV-F2D94E commands failed due to the firmware file specified by the script not being in the correct location 301 +** The commands which failed due to an "unknown error" failed because they weren't reachable at the specified connection address due to some quirks with this specific LAN configuration 302 +** The remaining command sections were manually cancelled before they could complete 303 +[[image:sm4.png||height="205" width="904"]] 304 + 258 258 == Package Update Tool == 259 259 260 260 The Package Update Tool [[image:1663622297411-164.png]] is a very convenient way of [[performing firmware updates>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome||anchor="HPackageUpdateTool28.puf29"]] for networked devices and [[loading the ShowRunnerCLC™ program>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HProgramLoad"]] to processors.
- fm1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +10.2 KB - Content
- fm2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.4 KB - Content
- fm3a.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +1.5 KB - Content
- fm3b.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.1 KB - Content
- sm4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.7 KB - Content