Changes for page Toolbox Basics

Last modified by Alexander Mott on 2024/03/19 21:00

From version 63.2
edited by Alexander Mott
on 2023/12/14 21:26
Change comment: (Autosaved)
To version 71.1
edited by Alexander Mott
on 2023/12/14 22:54
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -36,7 +36,7 @@
36 36  
37 37  These elements have various functions:
38 38  
39 -1. Address Book Menu - Used to view and edit the current address book, or to change the active Address Book to a different Address Book
39 +1. Address Book Menu - Used to view and edit the current address book, or to change the active Address Book to a different Address Book. See [[Troubleshooting a Failed Connection>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoAddressBook"]] below for information about creating an Address Book
40 40  1. Known Device Dropdown - This drop down menu can also be used to connect to devices in the current Address Book. If the currently connected device is in the Address Book, it's name in the Address Book will be displayed here
41 41  1. Manual Connection Menu - This menu is used to manually connect to a device that is not in the current Address Book. It can be used regardless of the connection type or device being connected to:
42 42  1*. [[image:1663625644870-585.png]]
... ... @@ -169,7 +169,7 @@
169 169  
170 170  === Export to Address Book ===
171 171  
172 -Address Books provide a convenient way to easily connect to different devices without memorizing all the different IP addresses and credentials for devices on your network. When an Address Book has been created for a job, you are able to connect to specific devices using the dropdown menu on the lower left of the tool instead of manually inputting the IP address or hostname using the Pencil menu. Note that when exporting devices to the Address Book, it is possible to add devices by either Hostname or by IP Address, and if the device settings are modified then it may be necessary to update your Address Book or create a new one.
172 +Address Books [[image:1702589379487-339.png]] provide a convenient way to easily connect to different devices without memorizing all the different IP addresses and credentials for devices on your network. When an Address Book has been created for a job, you are able to connect to specific devices using the dropdown menu on the lower left of the tool instead of manually inputting the IP address or hostname using the Pencil menu. Note that when exporting devices to the Address Book, it is possible to add devices by either Hostname or by IP Address, and if the device settings are modified then it may be necessary to update your Address Book or create a new one.
173 173  
174 174  To create an Address Book in Toolbox:
175 175  
... ... @@ -253,11 +253,32 @@
253 253  
254 254  == Script Manager ==
255 255  
256 -Load Scripts are .txt files that allow you to automate certain tasks by connecting to a device and executing a predetermined sequence of commands, and the Script Manager tool [[image:1663622272369-417.png]] is where Load Scripts can be opened and executed.
256 +Load Scripts are .txt files that allow you to automate certain tasks by connecting to a device and executing a predetermined sequence of commands, and the Script Manager [[image:1663622272369-417.png]] is where Load Scripts can be opened and specific sets of commands executed.
257 257  
258 +To use a Load Script with the Load Script Manager:
259 +
260 +* Open the Load Script Manager in Toolbox
261 +* Right-click anywhere in the Load Script Manager, select "Load Script...", and locate your Load Script .txt file
262 +* The window will populate with all of the different command sets defined in the Load Script
263 +** Ensure that you are connected to your devices by the method required based on the connection type listed in the "Connection" column
264 +** This example script is expecting to connect to devices over Ethernet using their hostname
265 +[[image:sm1.png||height="218" width="954"]]
266 +* Select the command sets you would like to execute by ctrl+clicking or shift+clicking them and then right-click and "Start Selected" to begin executing the commands
267 +** If no commands are currently running, the "Start All" option will also be available. Note that the number of concurrent command sections may be limited by the load script, so even if "Start All" is selected there may only be e.g. 10 command sets that actually start
268 +** If commands are currently running, you can cancel them using this right-click menu as well
269 +[[image:sm2.png]]
270 +* While commands are running, their current status and progress are displayed under the various columns displayed in the Script Manager
271 +[[image:sm3.png||height="189" width="835"]]
272 +* Once a command section has executed all commands, it will display the success or failure of the commands
273 +** In this example, all of the commands failed for different reasons:
274 +** ZUMNET-JBOX-16A-LV-F2D94E commands failed due to the firmware file specified by the script not being in the correct location
275 +** The commands which failed due to an "unknown error" failed because they weren't reachable at the specified connection address due to some quirks with this specific LAN configuration
276 +** The remaining command sections were manually cancelled before they could complete
277 +[[image:sm4.png||height="205" width="904"]]
278 +
258 258  == Package Update Tool ==
259 259  
260 -The Package Update Tool is a very convenient way of [[performing firmware updates>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome||anchor="HPackageUpdateTool28.puf29"]] for networked devices and [[loading the ShowRunnerCLC™ program>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HProgramLoad"]] to processors.
281 +The Package Update Tool [[image:1663622297411-164.png]] is a very convenient way of [[performing firmware updates>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome||anchor="HPackageUpdateTool28.puf29"]] for networked devices and [[loading the ShowRunnerCLC™ program>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Processor Setup.WebHome||anchor="HProgramLoad"]] to processors.
261 261  
262 262  While the Package Update Tool can be opened from within Toolbox, Chief Integrations does not recommend it as doing so will lock Toolbox until the .puf is finished loading to the device. Instead, we recommend to closing Toolbox (or at least closing any Toolbox connections to devices that you intend to update) and double-clicking the .puf file to open the Package Update Tool in a separate window. This allows you to open multiple instances of the Package Update Tool and load .puf files to multiple devices at once. **Exercise caution when updating firmware for multiple devices simultaneously,** as some devices will reboot as part of the update process which may disrupt connection to downstream devices.
263 263  
1702589379487-339.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +258 bytes
Content
sm1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +26.6 KB
Content
sm2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +8.3 KB
Content
sm3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +30.5 KB
Content
sm4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +35.7 KB
Content