Changes for page Toolbox Basics
Last modified by Alexander Mott on 2024/03/19 21:00
To version 46.1
edited by Alexander Mott
on 2023/12/12 22:26
on 2023/12/12 22:26
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -106,11 +106,12 @@ 106 106 11*1*. You can verify this by opening the Windows Command Line tool and running "ipconfig" command to view your current adapter settings 107 107 1. Open Toolbox and then open the desired tool 108 108 1. Connect to the device: 109 -1*. If you have created an address book (see [[ TroubleshootingaFailedConnection>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoAddressBook"]] below), then select the device from the drop down menu109 +1*. If you have created an address book (see [[Export to Address Book>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoAddressBook"]] below), then select the device from the drop down menu 110 110 1*. If you have not created an address book, then you should click the Pencil Icon to open the Manual Connection Menu: 111 111 1*1. Leave the connection type as "TCP" 112 -1*1. Type in the IP address of the device you wish to connect to 112 +1*1. Type in the IP address or Hostname of the device you wish to connect to 113 113 1*1. Generally, the "Auto Detect" box should be left at "Auto Detect", though if you know what type of connection you need then you can manually change it 114 +1*1*. CEN-GWEXERs with Authentication enabled require manually setting the connection type to "TSL/SSL" 114 114 1*1. Leave Model, Hostname, and Serial fields blank 115 115 1*1. If the device has authentication enabled, expand the Advanced options and input the username and password 116 116 1*1. Click "OK" ... ... @@ -120,6 +120,39 @@ 120 120 1*. If the device has just recently powered up, it may take a few minutes to completely wake up before it can be connected to 121 121 1*. If you have issues connecting, see [[Troubleshooting a Failed Connection>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HTroubleshootingaFailedConnection"]] below 122 122 124 +== == 125 + 126 +== Troubleshooting a Failed Connection == 127 + 128 +"Device refused to identify" 129 + 130 +* This message typically means that the device is not online or could not be connected to 131 +* This message may also occur when a device has blocked your username or IP address due to making too many incorrect login attempts 132 +** IP addresses are blocked for 24 hours by default, but you can attempt to circumvent this block by changing your IP address and trying again 133 +** Users are blocked for 30 minutes by default, and it is only possible to circumvent this if another user has already been created, otherwise you must wait for the block to expire before connecting again 134 +** The below commands are useful if you are able to connect to the processor through some other means (specific commands may vary depending on the device): 135 +*** ##listblockedip## and ##remblockedip## commands can be used to view/unblock an IP address 136 +*** ##listlockeduser## and ##remlockeduser## commands can be used to view/unblock specific users 137 +*** ##setloginattempts## and ##setlockouttime## commands can be used to modify how many login attempts are allowed before blocking an IP address and how long an address will be blocked 138 +*** ##setuserloginattempts## and ##setuserlockouttime## commands are used to modify how many login attempts are allowed before blocking a user and how long that user will be blocked 139 +*** ##setlogoffidletime## command can be used to modify how long you can be inactive before the processor automatically logs you out 140 + 141 +"Device not found in database" 142 + 143 +* This message typically means that the version of your device database is out of date and the device being connected to is not in it. Use Crestron's MasterInstaller tool to ensure that Toolbox and all installed Crestron components are up-to-date 144 + 145 +See our FAQ for additional tips: 146 + 147 +* [[I can't connect to my processor via Ethernet?>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20processor%20via%20Ethernet]] 148 +* [[I can't connect to a 4-Series processor via USB?>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%204-Series%20processor%20via%20USB]] 149 + 150 += Basic Tool Usage = 151 + 152 +(% class="box warningmessage" %) 153 +((( 154 +This section is under construction: please check back at alater date for more information on using tools in Toolbox 155 +))) 156 + 123 123 == Device Discovery Tool == 124 124 125 125 Crestron's Device Discovery Tool is used to "discover" any Crestron devices which are connected to your laptop. The most useful feature of the Device Discovery Tool is the ability to export all discovered devices to either a "Device Summary" text file or an Address Book. Discovered devices are listed in a scrollable list on the left side of the menu, and double clicking a discovered device will bring up additional configuration options on the right side. Below is an overview of the Device Discovery Tool UI: ... ... @@ -172,37 +172,7 @@ 172 172 173 173 Note that when exporting devices to the Address Book, it is possible to add devices by either Hostname or by IP Address. On systems with a DHCP server, it is recommended to add devices by Hostname, but only after the final hostnames have been set for all devices. 174 174 175 -== Troubleshooting a Failed Connection == 176 - 177 -"Device refused to identify" 178 - 179 -* This message typically means that the device is not online or could not be connected to 180 -* This message may also occur when a device has blocked your username or IP address due to making too many incorrect login attempts 181 -** IP addresses are blocked for 24 hours by default, but you can attempt to circumvent this block by changing your IP address and trying again 182 -** Users are blocked for 30 minutes by default, and it is only possible to circumvent this if another user has already been created, otherwise you must wait for the block to expire before connecting again 183 -** The below commands are useful if you are able to connect to the processor through some other means (specific commands may vary depending on the device): 184 -*** ##listblockedip## and ##remblockedip## commands can be used to view/unblock an IP address 185 -*** ##listlockeduser## and ##remlockeduser## commands can be used to view/unblock specific users 186 -*** ##setloginattempts## and ##setlockouttime## commands can be used to modify how many login attempts are allowed before blocking an IP address and how long an address will be blocked 187 -*** ##setuserloginattempts## and ##setuserlockouttime## commands are used to modify how many login attempts are allowed before blocking a user and how long that user will be blocked 188 -*** ##setlogoffidletime## command can be used to modify how long you can be inactive before the processor automatically logs you out 189 - 190 -"Device not found in database" 191 - 192 -* This message typically means that the version of your device database is out of date and the device being connected to is not in it. Use Crestron's MasterInstaller tool to ensure that Toolbox and all installed Crestron components are up-to-date 193 - 194 -See our FAQ for additional tips: 195 - 196 -* [[I can't connect to my processor via Ethernet?>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20processor%20via%20Ethernet]] 197 -* [[I can't connect to a 4-Series processor via USB?>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%204-Series%20processor%20via%20USB]] 198 - 199 -= Basic Tool Usage = 200 - 201 -(% class="box warningmessage" %) 202 -((( 203 -This section is under construction: please check back at alater date for more information on using tools in Toolbox 204 -))) 205 - 209 +(% class="wikigeneratedid" %) 206 206 == Text Console == 207 207 208 208 == File Manager ==