Changes for page Toolbox Basics
Last modified by Alexander Mott on 2024/12/02 18:48
From version 42.1
edited by Alexander Mott
on 2023/04/10 19:37
on 2023/04/10 19:37
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -28,7 +28,7 @@ 28 28 29 29 = Connecting to Devices = 30 30 31 -In order to connect to any lighting devices, your computer must be physically connected to the lighting device or the lighting network. Typically, this is achieved via TCP (i.e. Ethernet or WiFi) or USB (usually a USB-A to USB-B cable), though some older devices may require an RS-232 serial connection. 31 +In order to connect to any lighting devices, your computer must be physically connected to the lighting device or the lighting network. Typically, this is achieved via TCP (i.e. Ethernet or WiFi) or USB (usually a USB-A to USB-B cable), though some older devices may require an RS-232 serial connection or a different USB cable. 32 32 33 33 Any Toolbox tool which requires connecting to a device has several buttons and fields at the lower left which relate to device connection: 34 34 ... ... @@ -84,7 +84,7 @@ 84 84 1*. If the lighting network is on the building LAN, then you may need to reach out to the building's IT department for instructions on how to access the lighting network or VLAN. 85 85 1. Use a Cat 5a or Cat 6 cable to connect your laptop to the lighting network at an open port 86 86 1*. Most newer laptops will require some sort of adapter in order to connect to a Cat 5a/6 cable 87 -1. Configure your laptop's network settings to be compatible with the lighting network: 87 +1. Configure your laptop's network settings ([[FAQ page>>https://wiki.chiefintegrations.com/FAQ/How%20do%20I%20change%20my%20computer%27s%20network%20settings]]) to be compatible with the lighting network: 88 88 11. Navigate to Control Panel>Network and Internet>Network Connections 89 89 11. Locate the network adapter that is connected to the lighting network 90 90 11. Right click the network adapter and click "Properties" ... ... @@ -106,7 +106,7 @@ 106 106 11*1*. You can verify this by opening the Windows Command Line tool and running "ipconfig" command to view your current adapter settings 107 107 1. Open Toolbox and then open the desired tool 108 108 1. Connect to the device: 109 -1*. If you have created an address book, then select the device from the drop down menu 109 +1*. If you have created an address book (see [[Troubleshooting a Failed Connection>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Toolbox Basics.WebHome||anchor="HExporttoAddressBook"]] below), then select the device from the drop down menu 110 110 1*. If you have not created an address book, then you should click the Pencil Icon to open the Manual Connection Menu: 111 111 1*1. Leave the connection type as "TCP" 112 112 1*1. Type in the IP address of the device you wish to connect to ... ... @@ -152,6 +152,7 @@ 152 152 1. Click the Write Device Summary button and save the Device Summary to your computer 153 153 1*. Though saved as a text file, the Device Summary is actually a table of comma separated values 154 154 1*. Renaming DeviceSummary.txt to DeviceSummary.csv will allow it to be opened and manipulated in common spreadsheet software such as Microsoft Excel or LibreOffice Calc 155 +1**. Note that this .csv will have whitespace, so it may be beneficial to "clean" it using Excel's "=TRIM()" function 155 155 156 156 Below is an example of a Device Summary for a fully-configured Zūm Wired job: 157 157 ... ... @@ -176,12 +176,25 @@ 176 176 "Device refused to identify" 177 177 178 178 * This message typically means that the device is not online or could not be connected to 179 -* This message will also occur if too many login attempts are made with the incorrect username/password. When this happens, you either need to wait until your IP address is no longer blocked or change your IP address and attempt to login again. 180 +* This message may also occur when a device has blocked your username or IP address due to making too many incorrect login attempts 181 +** IP addresses are blocked for 24 hours by default, but you can attempt to circumvent this block by changing your IP address and trying again 182 +** Users are blocked for 30 minutes by default, and it is only possible to circumvent this if another user has already been created, otherwise you must wait for the block to expire before connecting again 183 +** The below commands are useful if you are able to connect to the processor through some other means (specific commands may vary depending on the device): 184 +*** ##listblockedip## and ##remblockedip## commands can be used to view/unblock an IP address 185 +*** ##listlockeduser## and ##remlockeduser## commands can be used to view/unblock specific users 186 +*** ##setloginattempts## and ##setlockouttime## commands can be used to modify how many login attempts are allowed before blocking an IP address and how long an address will be blocked 187 +*** ##setuserloginattempts## and ##setuserlockouttime## commands are used to modify how many login attempts are allowed before blocking a user and how long that user will be blocked 188 +*** ##setlogoffidletime## command can be used to modify how long you can be inactive before the processor automatically logs you out 180 180 181 181 "Device not found in database" 182 182 183 -* This message typically means that the version of your device database is out of date and the device being connected to is not in it. Use Crestron's MasterInstaller tool to ensure all Crestron components are up-to-date 192 +* This message typically means that the version of your device database is out of date and the device being connected to is not in it. Use Crestron's MasterInstaller tool to ensure that Toolbox and all installed Crestron components are up-to-date 184 184 194 +See our FAQ for additional tips: 195 + 196 +* [[I can't connect to my processor via Ethernet?>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%20my%20processor%20via%20Ethernet]] 197 +* [[I can't connect to a 4-Series processor via USB?>>https://wiki.chiefintegrations.com/FAQ/I%20can%27t%20connect%20to%204-Series%20processor%20via%20USB]] 198 + 185 185 = Basic Tool Usage = 186 186 187 187 (% class="box warningmessage" %) ... ... @@ -203,7 +203,7 @@ 203 203 204 204 Whenever Toolbox is open, Toolbox also starts a separate process called the Crestron Toolbox VPT COM server. This process appears in the system tray with the following icon when active: [[image:1663630447432-699.png]] 205 205 206 -Occasionally, something go eswrong with the VPT COM Server process which will prevent Toolbox from functioning correctly. To solve this problem, take the following steps:220 +Occasionally, something might go wrong with the VPT COM Server process which will prevent Toolbox from functioning correctly. To solve this problem, take the following steps: 207 207 208 208 1. Close Crestron Toolbox 209 209 1. Press CTRL+SHIFT+ESC to open Windows Task Manager