Changes for page Startup Checklist
Last modified by Alexander Mott on 2024/12/02 19:09
From version 8.1
edited by Alexander Mott
on 2023/12/12 16:30
on 2023/12/12 16:30
Change comment:
There is no comment for this version
To version 7.1
edited by Alexander Mott
on 2023/05/19 16:24
on 2023/05/19 16:24
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,20 +8,16 @@ 8 8 ** Ensure you have the [[required tools and software>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Preparing to Go On-Site.WebHome]] 9 9 ** Ensure the jobsite is meets [[site readiness requirements>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Site Readiness Checklist.WebHome]] 10 10 * Once on-site: 11 -** Configure authentication settings for networked devices 12 12 ** Configure IP settings for networked devices (processors, TSW touch panels, DIN-CENCN-2s, ZUMNET-JBOXs, GLPACs, etc.) 13 -** Configure clock and time zone for processors 14 -** Update firmware for all networked devices (excluding Zūm Net devices) 12 +** Configure clock and timezone for processors 13 +** Update firmware for all networked devices 14 +** If necessary, update firmware for Zūm Net and Cresnet devices 15 15 ** Load ShowRunnerCLC™ program, license, and configuration file to the processor 16 16 ** Load the ShowRunnerCLC™ UI to any touchscreens 17 17 ** Load the ShowRunnerCLC™ expansion program to any GLPACs 18 18 ** Configure the IP table for any required devices (TSW touch panels, DIN-CENCN-2s, ZUMNET-JBOXs, GLPACs, etc.) 19 -*** Ensure [[SSL Setup>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.CEN-GWEXER Setup.WebHome||anchor="HSSLSetup"]] has been performed for devices that require it 20 -** Poll Cresnet/acquire infinetEX devices to gateways and verify devices are online in Toolbox 21 -** Assign Cresnet/RFID IDs to devices and verify they are reporting online to ShowRunnerCLC™ 22 -** Update firmware for Zūm Net devices 23 -*** See [[Zūm Wired specific>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.Updating Firmware.WebHome||anchor="HZ16BmWiredSpecificNotes"]] firmware notes 24 -** If necessary, update firmware for any Cresnet and RFID devices 19 +** Poll Cresnet and verify devices are online in Toolbox 20 +** Assign Cresnet IDs to devices and verify they are reporting online to ShowRunnerCLC™ 25 25 ** Verify load schedule and fixture functionality 26 26 *** Toggle each load individually and verify they dim and switch correctly 27 27 *** Verify loads are assigned to correct areas