Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,28 +1,26 @@ 1 -This is a broad-strokes checklist for what needs to be completed by a technician for a S howRunnerCLC™ startup. This checklist is not 100% comprehensive and does not go into detail for each step.1 +This is a broad-strokes checklist for what needs to be completed by a technician for a SHOWRUNNER™ startup. This checklist is not 100% comprehensive and does not go into detail for each step. 2 2 3 -More detailed specifics and troubleshooting information are available in the [[S howRunnerCLC™ Startup Guide>>doc:SHOWRUNNER™ Setup Guide.WebHome]].3 +More detailed specifics and troubleshooting information are available in the [[SHOWRUNNER™ Startup Guide>>doc:SHOWRUNNER™ Setup Guide.WebHome]]. 4 4 5 5 Startup Checklist: 6 6 7 7 * Before arriving on-site: 8 8 ** Ensure you have the [[required tools and software>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Preparation.Preparing to Go On-Site.WebHome]] 9 -** Ensure the jobsite is meets [[site readiness requirements>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide. Preparation.Site Readiness Checklist.WebHome]]9 +** Ensure the jobsite is meets [[site readiness requirements>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.Site Readiness Checklist.WebHome]] 10 10 * Once on-site: 11 -** Configure IP settings for networked devices (processors, TSW touch panels, DIN-CENCN-2s, ZUMNET-JBOX s,GLPACs,etc.)11 +** Configure IP settings for networked devices (processors, TSW touch panels, DIN-CENCN-2s, ZUMNET-JBOX, etc.) 12 12 ** Configure clock and timezone for processors 13 13 ** Update firmware for all networked devices 14 14 ** If necessary, update firmware for Zūm Net and Cresnet devices 15 -** Load ShowRunnerCLC™ program, license, and configuration file to the processor 16 -** Load the ShowRunnerCLC™ UI to any touchscreens 17 -** Load the ShowRunnerCLC™ expansion program to any GLPACs 18 -** Configure the IP table for any required devices (TSW touch panels, DIN-CENCN-2s, ZUMNET-JBOXs, GLPACs, etc.) 15 +** Load SHOWRUNNER™ program to the processor 16 +** Load the SHOWRUNNER™ UI to any touchscreens 17 +** Load the SHOWRUNNER™ expansion program to any GLPACs 19 19 ** Poll Cresnet and verify devices are online in Toolbox 20 -** Assign Cresnet IDs to devices and verify they are reporting online to S howRunnerCLC™19 +** Assign Cresnet IDs to devices and verify they are reporting online to SHOWRUNNER™ 21 21 ** Verify load schedule and fixture functionality 22 -*** Toggle each load individually and verify they dim and switch correctly 23 23 *** Verify loads are assigned to correct areas 22 +*** Verify loads dim and switch correctly 24 24 *** Assign friendly load labels as necessary 25 -*** Use the "Verification" checkbox to add a verified timestamp to the load 26 26 ** Verify occupancy sensors 27 27 *** Verify correct area assignments 28 28 *** Adjust timeouts and sensitivities as necessary ... ... @@ -36,5 +36,3 @@ 36 36 *** Verify correct area assignments 37 37 *** Adjust sensitivity as required 38 38 ** Set up any schedules as required per the sequence of operations 39 -** Complete functionality test (QC, make sure each room functions from an end-user perspective) 40 -** End-user training