Changes for page Required Tools and Software
Last modified by Alexander Mott on 2024/01/05 19:13
From version 25.1
edited by Alexander Mott
on 2022/06/30 17:39
on 2022/06/30 17:39
Change comment:
There is no comment for this version
To version 8.1
edited by Alexander Mott
on 2022/06/20 17:20
on 2022/06/20 17:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,90 +2,53 @@ 2 2 3 3 The SHOWRUNNER™ program has many features to simplify and streamline Crestron lighting control startups, reducing the amount of technical knowledge required and time spent on-site. Even so, there are a number of different software programs and tools required for a successful SHOWRUNNER™ startup. 4 4 5 - "Required"items areabsolutelynecessaryfor startup,while"Recommended"itemsare notstrictlynecessarybutgoodtohave.5 +There is a baseline of software and tools required for all startups, but depending on the job additional software or tools may be required. 6 6 7 +"Required" items are absolutely necessary, "Recommended" items are not strictly necessary but are good to have, and "Optional" items are things that a technician shouldn't need but which are useful for troubleshooting installation issues. 8 + 7 7 ==== All Startups ==== 8 8 9 - ======Required:======11 +Required: 10 10 11 11 * Windows Laptop (Windows 10 recommended) 12 -** Internet access is required to generate and download the SHOWRUNNER™ license on-site 13 -*** Most cellphones can be used as hot spots for this purpose, but a **dedicated hot spot **is** highly recommended** 14 -** Laptop must have an RJ-45 Ethernet port or a suitable adapter 15 -* Software: 16 -** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (requires Crestron account; always update to the latest version) 14 +** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (be sure to update to the latest version) 17 17 ** Web Browser ([[Chrome>>https://www.google.com/chrome/]] or [[Firefox>>https://www.mozilla.org/en-US/firefox/new/]]) 18 18 ** Text Editor ([[Notepad++>>https://notepad-plus-plus.org/downloads/]] or [[VS Code>>https://code.visualstudio.com/]] recommended) 19 -* Downloads: 20 -** Latest [[SHOWRUNNER™ .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] 21 -** Job-specific SHOWRUNNER™ configuration .json file 22 -** Latest Crestron firmware for installed devices 23 -** Latest [[SHOWRUNNER™ UI .puf file>>https://files.chiefintegrations.com/index.php/s/WHNzXrrZbB5jC3E]] (only required for jobs with touchscreens other than TSW-770) 24 -** SHOWRUNNER™ GLPAC expansion program (only required for jobs with GLPAC controllers) 25 -* Cables: 26 -** Cat5/Cat5e/Cat6 Ethernet cable (multiple cables and multiple lengths are recommended) 27 -** USB-A to USB-B cable (required for most devices; 15' minimum cable length recommended for jobs with GLPACs) 28 -** USB-A to Mini-B cable (required for RMC3 processors only) 29 -** USB-A to Micro-B cable (required for CEN-GWEXER, RMC4 processors, and some other devices) 17 +* Cables 18 +** Cat5/Cat5e/Cat6 Ethernet cable with any necessary adapters to connect to your laptop 19 +*** Multiple cables and multiple lengths recommended 30 30 31 - ======Recommended:======21 +Recommended: 32 32 33 -* Secondary device with internet access (e.g. tablet, second laptop, or cell phone) and remote access software (such as Splashtop or TeamViewer) 34 -** This allows you to "untether" yourself from the lighting network; your laptop stays connected to the lighting network, but is controlled via the remote access software on your second device 35 -* Remotes: 36 -** [[GLS-REMOTE-ODT/OIR>>https://www.crestron.com/Products/Control-Surfaces/Remotes/Lighting-System-Companion-Remotes/GLS-REMOTE-ODT-OIR]] (**required **for jobs with Crestron occupancy sensors) 37 -** [[GLPPA-REMOTE-PROG>>https://www.crestronlighting.com/product/products-control-surfaces-remotes-lighting-system-companion-remotes-glppa-remote?sku=GLPPA-REMOTE-USER&user=67fefcbf860500c91fb9509b97bdfc5a]] (**required **for jobs with GLPPs) 38 -** RC3 Service Remote or [[Smart Remote>>https://www.steinel.de/en/sensors-professional/products/products/sensors/accessories/remote-control-smart-remote-009151.html]] (**required **for jobs with Steinel occupancy sensors) 39 -* Hand Tools: 40 -** Standard Screwdriver (#1 and #2 Phillips, 1/4" and 3/16" Slotted) 41 -** Precision Screwdriver (2.5mm or 3/32" Slotted; for use with Phoenix Connectors) 42 -** Wire Stripper (standard Cresnet cable has both 18 AWG and 22 AWG stranded wires) 43 -** Bright flashlight or laser pointer (for testing photocells) 44 -** RJ-45 crimper + terminations (the EC should make these terminations, but oftentimes their tools are in poor condition and unsuitable for making good terminations) 45 -* Measurement devices: 46 -** Low-voltage Multimeter (continuity testing and low voltage DC measurements are frequently required for troubleshooting) 47 -** Ethernet Network Cable Tester (these are expensive, but useful for verifying Ethernet run lengths and terminations) 48 -* Software: 49 -** Chief Integrations Remote Help Tool (download from [[http:~~/~~/help.chiefintegrations.com/>>http://help.chiefintegrations.com/]]; requires internet access on-site to use) 50 -** SFTP client (such as FileZilla or WinSCP; **required** for ZUM-HUB4 deployments) 51 -** SSH client (such as PuTTY) 52 -** File archiver (such as 7-Zip or WinRAR) 53 -** IP scanning utility (such as Advanced IP Scanner) 54 -** DHCP server software (or the [[built-in SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]]) 23 +* Dedicated hotspot for Internet access on-site 24 +* [[Chief Integrations' SOS Tool>>http://help.chiefintegrations.com/]] (requires internet access on-site to use) 55 55 56 - ==== Zūm Wired Startups ====26 +Optional: 57 57 58 -Zūm Wired startups require all the items listed under "All Startups" plus the following: 28 +* Standard Screwdriver (#1 and #2 Phillips, 1/4" and 3/16" Slotted) 29 +* Precision Screwdriver (2.5mm or 3/32" Slotted; for use with Phoenix Connectors) 30 +* Wire Stripper (standard Cresnet cable has both 18 AWG and 22 AWG stranded wires) 31 +* Low-voltage Multimeter (continuity testing and low voltage DC measurements are frequently required for troubleshooting) 32 +* Ethernet Network Cable Tester (these are expensive, but useful for verifying Ethernet run lengths and terminations) 59 59 60 -==== ==Required:======34 +==== Zūm Wired Startups ==== 61 61 62 -* Bluetooth-capable Android device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed 63 -** The [[iOS Crestron Zūm app>>https://apps.apple.com/us/app/crestron-z%C5%ABm/id1212507034]] does not currently support Zūm Wired as of June 2022 64 -** Officially Android 5.0 is the minimum requirement, but Chief Integrations recommends Android 10.0 or higher 65 -** We have a short guide for using the Crestron Zūm App available [[here>>SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Crestron Zūm App Overview.WebHome]] 36 +Required: 66 66 67 -====== Recommended: ====== 38 +* Everything listed under "All Startups", plus: 39 +* Android 5.0 or newer mobile device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed 68 68 69 - *Router or third-party DHCP server software (**required **if the [[built-in SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]] isnot going to beused)41 +Recommended: 70 70 43 +* Everything listed under "All Startups", plus: 44 +* Router or DHCP server software (if 45 + 71 71 ==== DMX Startups ==== 72 72 73 - DMX startups requireall the items listedunder "All Startups" plus the following:48 +Required: 74 74 75 - ======Required:======50 +Recommended: 76 76 77 -* [[Pharos Designer 2>>https://www.pharoscontrols.com/downloads/software/designer-2/]] (for jobs using Pharos LPC) 78 -* [[Enttec NMU>>https://www.enttec.com/product/controls/dmx-ethernet-lighting-control/nmu/]] (for jobs using Enttec controllers) 52 +* 79 79 80 -====== Recommended: ====== 81 - 82 -* DMX Tester (e.g. a [[Swisson XMT-120A>>https://www.swisson.com/en/products/light-control/dmx-tester/]]) 83 -* XLR adapters (3-pin male/female, 5-pin male/female, RJ-45, etc.) 84 - 85 85 ==== DALI Startups ==== 86 - 87 -DALI startups require all the items listed under "All Startups" plus the following: 88 - 89 -====== Required: ====== 90 - 91 -* Crestron Toolbox DALI Commissioning Tool (usually included with [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] installation)