Changes for page Required Tools and Software
Last modified by Alexander Mott on 2024/01/05 19:13
From version 21.1
edited by Alexander Mott
on 2022/06/22 17:35
on 2022/06/22 17:35
Change comment:
There is no comment for this version
To version 12.1
edited by Alexander Mott
on 2022/06/20 22:04
on 2022/06/20 22:04
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,6 +2,8 @@ 2 2 3 3 The SHOWRUNNER™ program has many features to simplify and streamline Crestron lighting control startups, reducing the amount of technical knowledge required and time spent on-site. Even so, there are a number of different software programs and tools required for a successful SHOWRUNNER™ startup. 4 4 5 +There is a baseline of software and tools required for all startups, but depending on the type of job, additional software or tools may be required. 6 + 5 5 "Required" items are absolutely necessary for startup, while "Recommended" items are not strictly necessary but are good to have. 6 6 7 7 ==== All Startups ==== ... ... @@ -10,7 +10,8 @@ 10 10 11 11 * Windows Laptop (Windows 10 recommended) 12 12 ** Internet access is required to generate and download the SHOWRUNNER™ license on-site 13 -*** Most cellphones can be used as hot spots for this purpose, but a **dedicated hot spot **is** highly recommended** 15 +*** Most cellphones can be used as hot spots for this purpose 16 +*** Dedicated hot spot is** highly recommended** 14 14 ** Laptop must have an RJ-45 Ethernet port or a suitable adapter 15 15 * Software: 16 16 ** [[Crestron Toolbox>>https://www.crestron.com/Products/Control-Hardware-Software/Software/Development-Software/SW-TB]] (requires Crestron account; always update to the latest version) ... ... @@ -24,14 +24,15 @@ 24 24 ** SHOWRUNNER™ GLPAC expansion program (only required for jobs with GLPAC controllers) 25 25 * Cables: 26 26 ** Cat5/Cat5e/Cat6 Ethernet cable (multiple cables and multiple lengths are recommended) 27 -** USB-A to USB-B cable ( required for most devices;15' minimum cable length recommended for jobs with GLPACs)28 -** USB-A to Mini-B cable (required for RMC3 processors only)29 -** USB-A to Micro-B cable (required for CEN-GWEXER, RMC4 processors, and some other devices)30 +** USB-A to USB-B cable (15' minimum cable length recommended for jobs with GLPACs) 31 +** USB-A to Mini-B cable 32 +** USB-A to Micro-B cable 30 30 31 31 ====== Recommended: ====== 32 32 33 -* Secondary device with internet access (e.g. tablet, second laptop, or cell phone) and remote access software (such as Splashtop or TeamViewer) 34 -** This allows you to "untether" yourself from the lighting network; your laptop stays connected to the lighting network, but is controlled via the remote access software on your second device 36 +* Chief Integrations Remote Help Tool (download from [[http:~~/~~/help.chiefintegrations.com/>>http://help.chiefintegrations.com/]]; requires internet access on-site to use) 37 +* A secondary device with internet access (e.g. iPad, second laptop, or cell phone) with remote access software (such as Splashtop) 38 +** This allows you to "untether" yourself from the lighting network; the laptop stays connected to the lighting network and is able to be remotely accessed via the secondary device 35 35 * Remotes: 36 36 ** [[GLS-REMOTE-ODT/OIR>>https://www.crestron.com/Products/Control-Surfaces/Remotes/Lighting-System-Companion-Remotes/GLS-REMOTE-ODT-OIR]] (**required **for jobs with Crestron occupancy sensors) 37 37 ** [[GLPPA-REMOTE-PROG>>https://www.crestronlighting.com/product/products-control-surfaces-remotes-lighting-system-companion-remotes-glppa-remote?sku=GLPPA-REMOTE-USER&user=67fefcbf860500c91fb9509b97bdfc5a]] (**required **for jobs with GLPPs) ... ... @@ -45,22 +45,17 @@ 45 45 ** Low-voltage Multimeter (continuity testing and low voltage DC measurements are frequently required for troubleshooting) 46 46 ** Ethernet Network Cable Tester (these are expensive, but useful for verifying Ethernet run lengths and terminations) 47 47 * Software: 48 -** Chief Integrations Remote Help Tool (download from [[http:~~/~~/help.chiefintegrations.com/>>http://help.chiefintegrations.com/]]; requires internet access on-site to use) 49 49 ** FTP client (such as FileZilla or WinSCP) 50 50 ** SSH client (such as PuTTY) 51 51 ** File archiver (such as 7-Zip or WinRAR) 52 -** IP scanning utility (such as Advanced IP Scanner) 53 -** DHCP server software (or the [[built-in SHOWRUNNER™ DHCP Server>>doc:SHOWRUNNER™ User Guide & Wiki.Troubleshooting.DHCP Server.WebHome]]) 54 54 55 55 ==== Zūm Wired Startups ==== 56 56 57 57 Zūm Wired startups require all the items listed under "All Startups" plus the following: 58 58 59 -====== Required: ====== 60 +====== Required: ====== 60 60 61 -* Bluetooth-capable Android device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed 62 -** The [[iOS Crestron Zūm app>>https://apps.apple.com/us/app/crestron-z%C5%ABm/id1212507034]] does not currently support Zūm Wired as of June 2022 63 -** Officially Android 5.0 is the minimum requirement, but Chief Integrations recommends Android 10.0 or higher 62 +* Android 5.0 or newer mobile device with the [[Crestron Zūm app>>https://play.google.com/store/apps/details?id=com.crestron.zum]] installed 64 64 65 65 ====== Recommended: ====== 66 66